| 1 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core complete all as specified and as direcred. |
| 2 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 Core complete all as specified and as direcred. |
| 3 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core complete all as specified and as direcred. |
| 4 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core complete all as specified and as direcred. |
| 5 | Supply, laying, jointing and testing LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core complete all as specified and as direcred. |
| 6 | Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and getting out, pipe etc in soft/loose soil & getting out, complete all as directed. |
| 7 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 8 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed. |
| 9 | M&L for sand cushioning for cable protections using clean dry sand complete all as specified and directed. |
| 10 | Supply & Laying well burnt brick , locally available best quality (sub class \\"B\\" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified. |
| 11 | S&F in repair GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed. |
| 12 | S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc all as specified and directed. |
| 13 | M&L Cement Concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as Foundations to poles, Filling and Mass Concrete, complete all as specified and as directed. |
| 14 | Taking down and refixing LED street light fitting of wattage 35/45/60 Watts 230 V AC to poles checking of internal wiring, replacement of minor accessories such as nuts, bolts, washers, clamps, screws, PVC tape etc and re-fixing the same in proper position complete all as specified and directed |
| 15 | Dismantling of concrete poles/struts making goods disturbed surface of any size, complete all as specified and directed |
| 16 | Dismantling of ACSR or AAC conductors complete all as specified and directed |
| 17 | Dismantling cross-arms of MS channel or angle sections etc complete and setting aside for re-use with in 50m complete all as specified and directed |
| 18 | Dismantling and taking down old stay from LT poles duly unscrewing from poles complete all as specified and directed |
| 19 | Dismantling old GI Pipe any size any type complete all as specified and directed |
| 20 | Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 METRE long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally) above copping shall be painted with in alternate band/strip of black and yellow colour starting with black colour upto height of 1.5 from top of copping, writing MES Pole No. (8cm in height) with syntheic enamel paint (white colour) on base of black colour syntheic enamel paint 15cm dia, complete all as specified and as directed. NOTE: (i) Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. (ii) Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed and cost of Earthwork, demolition of Cement Concrete, etc. is deemed to be inclusive in Unit Rate Quoted. |
| 21 | S&F strret light bracket bend to shape made as required of 32/40 mm dia 1 mtr long GI pipe light grade fixed to pole/wall with flat iron clamp of size 40x6 mm two numnber with help of nuts and bolbts for fixing of street light fitting including making al electric connection including taking out old one complete all as specified and as directed. |
| 22 | Supply & fixing thermoplastic cable junction box for street lights of size 200x160x98 mm including terminals for cabole connection with IP protection duly fixed in poles with help of clamps nut bolts arrangement complete all as specified and directed. |
| 23 | Supply & fixing in replacement 1.5 sqmm PVC insuleted weather proof sheathed copper cable 3 core in steel conduit from junction box to street light properl fixed complete all as specified and directed. |
| 24 | Supply and fixing LED street light fitting 35 watt 230 V AC outdor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complee with IP 65/66 protection complete all as specifie and directed. |
| 25 | Cutting existing road surface or hard standing 0.45 Mtr depth (22 thick comprising bituminuous topping) for laying of pipes /cables and making good disturbed surfaces to match with existing surfaces. |
| 26 | M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation of pole, including necessary formwork ad required complete all as specified and as directed. |
| 27 | M&L providing plain cement concrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as coping for light pole, road cutting etc as required complete all as specified and directed. |
| 28 | M&L earthing complete with Galvanised steel Earth Plate Electrode 600mm x 600mm x 6mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI earth strip 32X6 mm by means of Bolts, Nuts, Check Nuts and Washers etc including Galvanised Iron protection Pipe 15 mm bore (dia) Light grade up to 7.5M height provison the earth lead to earth connection in the main distribution box with lugs and GI nuts, bolts earthing shall be done all as per shown in elctrical plate No 5 of SRR Part-I including necessary excavation in disintregrated hard soil and 20 mm dia GI pipe with funnel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test and testing in presence of Engr-in Charge. |
| 29 | M&L supply, fabrication, installation, connection, commissioning and testing of outdoor type LT feeder pillar box (CPRI approved) made out of 3.15 mm thick CRCA sheet metal, double door front and rear opeanable double door vertical type installed over properly supported legs suitability grouted to PCC with copper bus bar 200 Amps including following accessories :-(a) INCOMING(i) MCCB 100A four pole-01 Nos.(ii) Digital voltmeter 0-500 V with selector switch -1 Set(iii) Digital ammeter 0-30 Amp with 3 Nos CTs & Slecetor switch -02 set(iv) Phase indicator lamps (RYB) - 01 Set |
| 30 | S&F in repair, Cable jointing kit for LV/LT 1100 Volts cable for heat shrinkable type, End joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed. |
| 31 | S&F in repair, Cable jointing kit for LV/LT 1100 Volts cable for heat shrinkable type, End joint kit complete with jointing material and accessories suitable for 70 Sqmm to 150 sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed. |
| 32 | S&F in repair, Cable jointing kit for LV/LT 1100 Volts cable for heat shrinkable type, End joint kit complete with jointing material and accessories suitable for 185 Sqmm to 400 sqmm, 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, complete all as specified as directed. |
| 33 | Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 80 mm bore (dia) for passing of pipes, complete all as specified and as directed. Please Enable Macros to View BoQ information |