| 1 | Dismantling of floor hearth and wall tilling incl mortar beding removing serviceable tiles to store and rubbish off the premises as directed by the Engr-in-Charge |
| 2 | Demolition of cement concrete reinforced in any position including cut of bars as required, complete all as specified and directed. |
| 3 | Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete including removing debries ouside MD land all as specified and directed. |
| 4 | Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) |
| 5 | M&L for PCC type D2, 1:4:8 by using 40 mm graded aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed . |
| 6 | M&L for form work to sides of concrete foundations, footings, columns and plinth beams and similar work, complete all as specified and directed . |
| 7 | M&L for form work to sides and soffits of suspended slabs such as roof slabs, floor slabs and similar work N exc 200 mm thick (horizontal or sloping) complete all as specified and directed. |
| 8 | M & L for 50mm thick Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection,Floor topping etc , surfaces finished of concrete flooring with brooming complete all as spd u including provision of necessary construction joints filled with bitumen filler etc complete all as directed by Engr-in-Charge |
| 9 | S&F Mild steel CRS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed . |
| 10 | S&F Mild steel CRS TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed . |
| 11 | M&L for RCC type M-30 (20 mm graded aggregate) as in roof slab supported on walls, beams and columns in roofs etc. complete all as specified and directed . |
| 12 | M&L for RCC type M-30 (20 mm graded aggregate) as in foundations,including rafts,footing plinth beams, bases for column etc. complete all as specified and directed. |
| 13 | Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete artilcles and precast concrete block walling etc. Complete all as specified and directed. |
| 14 | M&L for Walling Porbandar stone masonary in CM 1:6 brought to courses, complete all as specified & directed by Engr-in-charge. |
| 15 | Taking down cement plaster or terrazzo from brick walls of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified. |
| 16 | M&L for Rendering 15mm thick on fair faces of Porbandar stone masonary surface in CM 1:4 complete all as specified and directed by Engr-in-charge. |
| 17 | M&L for Virified Ceramic tiles (square/ rectangular) polished Light coloured, area of each tiles not exceeding 0.36 sqm, in floors/Skirting set and jointed in neat cement slurry over and including 15mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 18 | M&L for Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations all as specified. |
| 19 | M&L for 20mm Granite (of any type) work table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite |
| 20 | M&L for washing,rubingdown and stoping of distempered and painted surfaces plastered/pointed surfaces(Dry distember,white / lime wash etc) and Applying two coats of Oil bound distember/water based distemper over a coat of primer including applying Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer in Charge |
| 21 | Material and Labour for 5mm thick rendering on concrete surfaces in cement mortar 1:3 finished even and smooth with out using extra cement on ceiling complete all as specified and as directed. |
| 22 | M&L for Complete removal of existing treatment from old plastered surfaces of ceiling (Dry distember,white / lime wash etc ) and Applying two coats of Oil bound distember/water based distemper over a coat of primer including applying Providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed by Engineer in Charge |
| 23 | M & L preparation of new plastered surfaces as in walls, soffits & facias of beam ,chajjas etc for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.all as specified . Make : berger ( Cat No Border - Sundrenched Sand 7T 1589 and Other Ext . wall - Sands of time 2P 0674) Weather coat all Guards or Equllent make and model as approved by GE |
| 24 | M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, add WPC @3% of cement weight(WPC paid separately), finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment/ specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 4 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. (Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (c ) Applying two coats of reflective Bituminous aluminium paint on top of APP membrane. |
| 26 | Supply only water proofing compound. |
| 27 | S&F Plain solid, straight chowkats and frames of second class soft wood (Kail) Wrought Framed rabatted on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed. |
| 28 | S&F 30mm thick flush shutters, solid core construction,with block board core and plywood face panels, both sides with deco rative face veneer with lipping/frame to match. |
| 29 | S&F in Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples.complete all as spd |
| 30 | S & F 4 mm thick sheet glass of selected quality in squares and not exceding 0.5 Sqm in each pane complete all as spd |
| 31 | Dismantiing of wall / floor and ceiling boards (fibre, pulp insulation etc) or insulation boards/ slabs / blankets any thickness including cover fillets complete all as specified and directed |
| 32 | Fixing only Prelaminated particle board 12mm thick, interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber frame work complete all as specified and directed |
| 33 | S&F 300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified. |
| 34 | S&F 150mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section and fixed all as specified and directed. |
| 35 | S&F 150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type,anodised all as specified. |
| 36 | S&F 100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed all as specified. |
| 37 | S&F to 25mm long handle CPVC ball valve for 25 mm bore pipe fixing in CPVC pipeline by cutting of pipeline and fixing with necessary fitting and solvent Complete all as specified and directed .(Make Prayag/Astral or equilant ) approved by Engr-in charge) |
| 38 | S & F Gl frame work (Size of Grid 605 x 605mm) for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed |
| 39 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long for false ceiling snap grid of size 605 x 605 mm complete all as specified and directed by Engr in Charge. |
| 40 | S&F Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat/curved surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh including any sunk or raised mouldings (fillets, metal frame work and G.I. wire mesh paid separately) complete all as specified and directed |
| 41 | S&F Door closer aluminium (extruded section) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed |
| 42 | S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed |
| 43 | M&L for Maroom/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering complete all as specified. |
| 44 | M&L for thick Hardcore of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complte all as specified and as directed. |
| 45 | M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate in floors, sub floors complte all as specified and as directed. |
| 46 | M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate in plinth protection with finished even & smooth without using extra cement complte all as specified and as directed. |
| 47 | Dismantling plain or corrugated steel sheeting or polycarbonate sheet, any gauge, thickness, in roof covering, cladding complete all as specified and directed. |
| 48 | Dismantling of mild steel work of any description not otherwise provided for all as specified and directed . |
| 49 | S&F Mortice lock, aluminium 4 lever vertical type, size 100 mm complete all as specified and directed |
| 50 | Taking down old point wiring complete for (light, fan, socket 5/15 amps, bell point etc) complete with all light fittings accessories , such as switches,sockets 5/15 Amps, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc all as speified and directed by Engineer -In-Charge. |
| 51 | Material and labour point wiring with 1.5 sqmm (nominal cross section area) single core PVC insulated unsheathed cable of 1100 Volts grade (FRLS) multistrand with copper conductor drawn through and including non metallic, rigid PVC conduit of adequate size with all fittings and conduit accessories concealed in wall/ceiling/floor/roof etc. including 1.6 mm thick sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover, cadmium plated iron screws for housing the switches, socket outlets including provision of 1.5 sqmm green in colour PVC insulated copper conductor single core multistrand (FRLS) for earth continuity conductor and connected to common earth dolly all as specified for the following:- |
| 52 | One light point controlled by one, one way switch |
| 53 | One ceiling /exhaust fan point controlled by one switch and regulator |
| 54 | All as per item No 51.00 above but for one 3 pin 5 amp socket out point on the same board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire. |
| 55 | All as per item No 51.00 above but for One3 pin 5 amps socket out let point on independent board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire. |
| 56 | All as per item No 51.00 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. |
| 57 | S & F Modular switch 1 way 6A, 1 module all as specified and directed by EIC. |
| 58 | S & F Ceiling rose, surface bakelite 65x50 mm three terminal |
| 59 | S & F modular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC. |
| 60 | S & F Modular switch 1 way 16A, 1 module all as specified and directed by EIC. |
| 61 | S & F modular socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC. |
| 62 | Taking down fan of any make/type/sweep,sealing cable end ,dismantling of blades and for repair /overhauling complete all as directed |
| 63 | M &L for Overhauling of ceiling fan /exhaust fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes,replacement of capacitor & reassmbling the same,& painting with similar colour ,fixing and connecting on its existing position and testing on completion all as specified and as directed . |
| 64 | M &L for Painting of ceiling fan/Exhaust Fan of any sweep complete including fan blade down rod with synthetic enamelled paint by spraying including cleaning and removing dust by polish paper and dirt and making smooth surface for painting ,filling cavities with filler |
| 65 | Fixing or hanging only ceiling fan after overhauling/repair of winding above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed |
| 66 | S & F in replacement LED tube light fittings 4 feet 1x20 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W ,holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge. |
| 67 | S & F in replacement MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240 Volts SPN with 12 way Double door IP-43-IK09 protection grade, |
| 68 | S & F in replacement MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63Amps complete all as specified & directed by Engr-In-Charge. |
| 69 | S & F in replacement MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63Amps |
| 70 | S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories complete all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC Conduit shall be measured as one unit. Please Enable Macros to View BoQ information |