| Sl. No. | Item Description |
| 1 | Taking down cement or cement plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. To receive new plaster complete all as specified and directed |
| 2 | M&L for Rendering 15 mm thick in CM 1:6 on surfaces or surface other than fair face of brick-work or on one side of lathing of stone masionary or concrete surfaces finished even and smooth without using extra cement, Complete all as specified and directed. |
| 3 | M&L for Rendering 15 mm thick in CM 1:4 on surfaces or surface other than fair face of brick-work or on one side of lathing of stone masionary or concrete surfaces finished even and smooth without using extra cement, Complete all as specified and directed. |
| 4 | M&L for rendering 10mm thick in CM 1:3 on ceiling of concrete surface and finishing the surface even and smooth all as specified and directed. |
| 5 | M&L for Preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed. |
| 6 | M&L for preparation of newly plastered surfaces of walls and applying 1 coat of wall care white putty, 1-2mm thick and further applying 2 coats of oil emulsion distemper over a coat of wall priming paint complete all as specified and as directed. |
| 7 | M & L for complete removal of existing treatment on walls and applying 1 coat of wall care putty,2mm thick and further applying two coat of oil bound distemper over one coat of primer paint complete all as specified and directed. |
| 8 | M&L for Preparation of new plastered surfaces in walls soffits, facia roof and applying Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. at any height including necessary scaffolding etc complete all as specified and directed of weather coat primer all as specified. |
| 9 | M&L for Preparation of old plastered/unplastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed. |
| 10 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing of rubbish complete all as specified and directed. |
| 11 | M & L for Glazed ceramic coloured printed tiles in vertical surface 300x450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tile including 15mm thick screed in cm (1:4) as in skirting/dado complete all as specified and directed |
| 12 | M & L double charged/ultracharged Virified Ceramic tiles 10 mm thick square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 20mm thick screed 1:4 as in flooring complete all as specified and directed. |
| 13 | All as per I/No 12 above but in skirting including 10mm backing coat CM in 1:4 complete all as specified and directed |
| 14 | M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,. set and jointed in neat cement slurry including 15mm thick screed 1:4 as in flooring complete all as specified and directed |
| 15 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar . |
| 16 | M & L Marble work 16 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms, skirting and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types, including 20mm thick screed bed in CM 1:4, jointed and pointed with grey cement slurry and pointing with white cement (1:3) using marble dust with admixture of pigment to match with shade cutting and polishing etc complete all as specified and directed |
| 17 | Demolition of PCC (unreinforced) in ground floors & pavings n exc 15 cm thickness (below or above ground level) |
| 18 | M&L 75mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate for plinth protection with finishing cement concrete surface even and smooth without using t extra cement omplete all as specified and directed |
| 19 | Taking down aluminium sliding window /ventilator including glass complete all as specified and directed. |
| 20 | S&F of Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/neoprene gasket required (Fittings shall bepaid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screwsall complete as per architectural drawings and the directions of Engineer-in-charge. |
| 21 | Taking down wooden chowkats or frames not exc 1.5sqm each with shutters (without taking off shutters from the frame) and disposing off complete all as specified |
| 22 | Taking down wooden chowkats or frames exc 1.5sqm but not exc 4sqm each with shutters (without taking off shutters from the frame) and disposing off complete all as specified |
| 23 | S&F PVC door solid frame of size 50mm x 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified. |
| 24 | S&F Factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tubes for top and bottom rails MS frameshall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain cover PVC sheets for top rail, lock rail and bottom rail on either side and as gap insertfor top rail and bottom rail, panelling of plain of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles, and rails with suitable PVC sheet beading and joined together with solvent cement supplying l and fixed in the frame at site as per specification and drawing. |
| 25 | S&F 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed |
| 26 | S&F 2nd class hardwood 35mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats |
| 27 | S&F 35mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mmB.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed |
| 28 | S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy. |
| 29 | S&F Overall length of cover plate 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete |
| 30 | S&F Mild Steel 300mm, ordinary rat tail rod patttern springs including roller & roller plate complete |
| 31 | S & F of 100 mm long stainless steel butt hinges, medium weight approved make ISI marked |
| 32 | S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. |
| 33 | S & F Aluminium handles 150mm long anidised aluminium , cast type, complete all as specified and directed by Engr-in-Charge. |
| 34 | M&L for preparation of new painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth including knotting and stopping and applying 2 coats of synthetic enamel paint over a prink primer (any tint/Shade) complete all as specified and directed. |
| 35 | Dismantling boarding, any description, fixed in any position with nails complete all as specified |
| 36 | S&F Hasp & staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate with screws 100mm size complete all as specified and directed |
| 37 | S&F 18mm thick prelim wooden finished PVC plastic celluka ply for shelves of cupboard etc including all required joining accessory complete all as specified and directed. |
| 38 | S & F concealed hinges for wardeobe, cupboard etc nickle plated complete all as specified and directed |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise described for of any description. |
| 40 | S& F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified |
| 41 | M&L painting on steel surface over 10 cmwidth or girth including preparation of surface and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 42 | Taking down aluminium decogrill of any size and any type all as specified |
| 43 | S&F aluminium grill with and including suitable aluminium anodised frame F/H section as requird manufactured by M/S Decogrill as per design No DG- 103 or equivatent 6.5 mm thick all as specified and as directed |
| 44 | S&F 4 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane all as specified and as directed |
| 45 | S&F Figured glass 4.0mm thick, pin head type & glazing with oil putty in squares n exc 0.5 sq.m in each pane |
| 46 | S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire & average width of aperture 1.40mm with aluminium wire staples |
| 47 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard & railing 60cm long |
| 48 | S&F in repair 25mm dia Stainless Steel curtain rod etc complete all as specified and directed |
| 49 | S&F in repair statinless steel bracket for curtain rod of 25mm dia for fixing in walls etc complete |
| 50 | Demolition and breaking up drain pipes 110/75mm of PVC SWR pipes laid in floor/wall complete all as specified |
| 51 | S&F of PVC (SWR) pipes 110mm single socketed in any length with rubber ring joints fixed to walls |
| 52 | S&F of PVC (SWR) bends 110mm dia access to door complete all as specified and directed. |
| 53 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal access to door |
| 54 | S&F 110mm PVC (SWR) vent cowl. |
| 55 | S&F 75mm PVC (SWR) vent cowl. |
| 56 | S&F 75mm bore PVC SWR pipe single socketed in any length with rubber ring joints laid in in floor/wall complete all as specified and directed. |
| 57 | S&F 75mm bore PVC (SWR) bands any radious complete all as specified and directed. |
| 58 | S&F 75 mm bore PVC (SWR) junction single (Single T) equal or unequal access door.. |
| 59 | M&L in 75 mm out let PVC floor trap, plain with openable (two piece type) grating including jointing with solvent cement. |
| 60 | M&L in 125/110 mm PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement. |
| 61 | Taking up or down steel tubing of 20 mm bore and connections |
| 62 | Taking up or down steel tubing of 25 mm bore and connections |
| 63 | S&F in Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls,ceilings or in floors etc pipes incl cutting/chases of walls etc 25mm inclluding fitting (such as elbow teen reducers, couplers short pieces, connection uion etc) whatever required as per dmanufacturer's instruction fixed on wall /ceiling complete all as specified and directed |
| 64 | S&F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls,ceilings or in floors etc pipes incl cutting/chases of walls etc 20mm inclluding fitting (such as elbow teen reducers, couplers short pieces, connection uion etc) whatever required as per dmanufacturer's instruction fixed on wall /ceiling complete all as specified and directed |
| 65 | S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed |
| 66 | S & F in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed |
| 67 | S & F Toilet paper holder, vitreous China,box type |
| 68 | S&F in repair 10 Litres, PVC valvless,syphonic action type, flushing cistern, low level, white, with inlet, ball vlave, float and handle including bracket complete all as specified and directed |
| 69 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400 mm excluding taps, waste coupling and waste pipe.including cutting for and pinning in ends of brackets or recting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed |
| 70 | S&Fin repair grating square 150 mm size of PTMT openable type. |
| 71 | S&F in repair PVC waste pipe suitable for wash hand basin/sink including fixing arrangement |
| 72 | S&F in repair 32 mm bore waste coupling of PTMT (half of full thread) complete all as specified and directedand as directed |
| 73 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm |
| 74 | S&F in repair 5.5mm thick looking mirror of size 600mm x 450mm, selected quality glass mounted on 6mm thick PVC sheet back surround by 10mmx 10mmx 1.6mm aluminium channel fixed with wooden plugs with chromium plated brass screw and cup washer using rawal plugs, complete all as specified and directed |
| 75 | S&F in repairs Fancy type bib taps, long shank chromium plated cast copper alloy 15mm bore with crutch screwed down and fixed complete all as specified and as directed. |
| 76 | S&F in repairs long shank CP Pillar taps 15 mm dia but fancy type, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts , screwed for pvc pipe and fixed complete all as specified and directed |
| 77 | S&F in repairs 15mm dia stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch , screwed at both ends for iron pipe or for unions complete all as specified and as directed |
| 78 | S&F in repair 120mm dia chromium plated overhead shower with arm complete all as specified and as directed |
| 79 | S & F in repair soap dish, fixed to tiled wall surfaces with plugs and chromium plated brass screws complete all as specified and as directed. |
| 80 | S & F in repair Brass chromium plated tubular towel rod 600mm long complete all as specified and as directed |
| 81 | Dismantling of water storage tank of exc 500 ltrs& n exc 1000 ltrs capacity complete all as specified and as directed |
| 82 | S&F 1000 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed |
| 83 | S&F in repair 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/20 m m - 2 1 0 g m s /25mm-455gms/ 40mm - 690 gms) complete all as specified and directed |
| 84 | M&L for PCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges finish surface even and smooth including form work complete all as specified and directed |
| 85 | Dismantling Plain or corrugated steel sheeting, any type / gauge, thickness and any patten of roof coverings, hanger door, hanger roof complete all as specified. |
| 86 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Eng-in-Charge. |
| 87 | S&F Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410-W(Gde- E-250) quality- B |
| 88 | Taking down / Dismantling of old textile covering from roof (old WPT) complete all as specified and directed. |
| 89 | Demolition of cement concrete (Concrete of any description andin any position not otherwise specifically provided for |
| 90 | M&L for PCC 1:2:4 type B-0 using (12.5 mm graded crushed stone aggregate) in padding concrete to over slab 40 mm thick (average) bedding layer mixed with WPC, finishing even and smooth without using extra cement complete all as specified and as directed.Note : WPC & APP shall be measured and paid separately. |
| 91 | M&L for rendering 10 mm thick (average) bedding layer on green concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, mixed with WPC, finishing even and smooth without using extra cement complete all as specified and as directed.Note: WPC shall be measured and paid separately. |
| 92 | Supply only integal water proofing compound. |
| 93 | M & L for Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed.Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions.(ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions.(iii) Applying two coats of Bituminous aluminium paint on top of APP membrane cover including testing on completion complete all as specified and directed. |
| 94 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, manholes, etc. or for laying cables/pipes, erecting poles etc. n exc 10 sqm on plan and getting out in soft/ disintegrated rock complete all as specified and as directed |
| 95 | Demolition and breaking up drain pipes 300mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar in floors including excavation and removal of soil complete all as specified and as directed |
| 96 | Demolition of stone/boulder masonry, built in cement mortar complete all as specified and as directed |
| 97 | M&L for Concrete bed Type D2 1:4:8 to 200mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed |
| 98 | M&L for reinforced concrete pipe of 200mm bore of pipe, class NP-2, laid and jointed with collars complete all as specified and as directed |
| 99 | M&L for pre-cast reinforced cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in manhole cover with plain fair surface including chamfers, weatherings, throatings, necessary form work and set in CM (1:6), placed in position complete all as specified and as directed |
| 100 | M & L Mild steel TMT bars 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed |
| 101 | M & L for Cutting into existing manholes of 225mm internal dia of pipes for connecting new drains, making good to pipe and rendering cutting out existing benching and forming branch channel in PCC (1:2:4) type B-1, smooth finished complete all as specified and as directed |
| 102 | M&L for walling of Porbandar stone masonry well bonded and solidly hearted built in CM 1:6 complete all as specified and as directed |
| 103 | Supply only integral waterproofing compound complete all as specified and as directed |
| 104 | M & L cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed |
| 105 | M&L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in copings, benching, and the like including weathering, sightly rounded or chamfered angles and throating complete all as specified and as directed |
| 106 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard dense soil complete all as specified and as directed |
| 107 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed as in rock complete all as specified and as directed |
| 108 | M&L for providing and laying at or near ground level factory made kerb stone in repairs of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever reqd complete. |
| 109 | M&L for even spreading of 25mm thick layer of sand cushioning incl watering & consolidation all as specified & directed by Engineer-in-charge. |
| 110 | M&L for machine pressed precast concrete inter locking paver blocks in repairs any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed by Engineer-in-charge. |
| 111 | M&L for preparation of new painted surfaces and applying two coat of synthetic enamel on brick, stone, concrete, asbestos cement or plaster surface all as specifed and directed. |
| 112 | Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed |
| 113 | M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit as required at site, ISI marked with all accessories of same grade fixed on wall/ceiling, terminated into and including modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light/ceiling/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed.Note:1) Rate quoted shall be included cost of wall chasealing and make good the disturbed surface.2) Conduit should be clamp at ceiling to avoid cutting in ceiling/slab. |
| 114 | All as per item No 113 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed |
| 115 | All as per item No 113 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the same board complete all as specified and as directed |
| 116 | M & L for point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit of dia not less than 20 mm, ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling, terminated into and including modular metal flush box, modular cover plate with frame top cover for mounting switches socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed |
| 117 | Supply & Fixing in repairs modular flush metal box with inner & outer sheet fixed, with screw for mounting modular switches, sockets, fan regulators etc for existing elect arrangements and connected to the existing elect wires, making good the distrubed area with cement work and paints as same existing backgound all as directed.Note : New modular switches, socket, regulators will be measured and paid separely.Size of the boxes suitable for 1/2 module |
| 118 | All as per item No. 117 here in before, but Size of the box suitable for 3 module |
| 119 | All as per item No. 117 here in before, but Size of the box suitable for 6/8 module |
| 120 | Supply & Fixing in repairs White inner, outer cover plate Modular type with frame, 1/2 module |
| 121 | All as per item No 120 here in before but 3 module |
| 122 | All as per item No 120 here in before but 6 module |
| 123 | All as per item No 120 here in before but 8 module |
| 124 | S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed |
| 125 | S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed |
| 126 | S & F in repairs Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed |
| 127 | S & F in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 voltscomplete all as specified and as directed |
| 128 | S & F in repairs stepped Modular electronic fan regulator flush type on the existing board all as directed. |
| 129 | S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed |
| 130 | Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed. |
| 131 | M & L for sub main wiring with two runs of single core 6 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit of as required size (not less than 20 mm dia ) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with Two run of 6 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit) |
| 132 | All as per item No 131 here in before, but two run of single core 4 sqmm and one run of 4.0 sqmm cables as earth continuity conductor all as directed. |
| 133 | Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed. |
| 134 | Supply and fix 25 Amps 2 module starter switch (ON&OFF) suitable for AC/ Gyeser complete all as specified and as directed by Engineer-in-charge.Make: Anchor Roma / Havell's / L&T |
| 135 | Supply and fixing socket outlet multipurpose 3 pin, 25 Ampp modular type completes all as specified and directed. Make: Anchor Roma / Havell's / L&T |
| 136 | S&F modular metal flush box 2 module concealed in wall complete with modular type cover plate 2 module for fixing of power socket and starter switch complete all as specified and as directed by Engineer-in-charge. Make: Legrand/Havell's/ L&T |
| 137 | S&F in repairs MCB DB TPN 4 way, 415 V with suitable bus bar double door type complete all as specified and as directed. |
| 138 | S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.Make: Lagrand, C&S, Havells, Schnieder , L&T or equivalent make as per PS. |
| 139 | S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed. |
| 140 | S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 141 | S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified. |
| 142 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 143 | Supply and fixing LED light fitting type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 144 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 145 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200 of sweep 250 mm complete.Note : Old UNSV exhaust fan will be deposited at AGE E/M Store. |
| 146 | Supply and fix in repairs Building Security LED fitting 60 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on Building by providing MS angle iron bracket of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed. |
| 147 | Supply and fix in repairs GI bracket pipe of size 32/40 mm dia medium grade bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surfaces by providing suitable MS flat iron 32x6 mm clamps 2 nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts,bolts & washers and removing of old unserviceable item complete all as specified and directed |
| 148 | M & L for replacement of Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts,check nuts and washers of brass as shown in electrical plate No. 5 of SSR part I including necessary excavation and earth work, GI Pipe 20 mm bore light grade for watering with Funnel,wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed. |
| 149 | M & L for taking out old UNSV celing fan safely after disconnecting all electrical connection. Preparation of old rusted surfaces of ceiling fan, then spray painting with one coat of synthetic enamel paint after primer and refixing the same at existing location after renovation of bldg complete all as specified and directed. |
| 150 | M & L for servicing and overhauling of ceiling fan including replacement of old capacitor, shackle reel assembly, nut bolt, split pin complete all as specified and directed. |
| 151 | Supply and fix down rod made of MS pipe medium grade 15mm dia of 300/450/600 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 152 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable all as specified. |
| 153 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified. |
| 154 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point.all as specified. |
| 155 | Supply and lay Double walled corrugated pipe (DWC ), heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed. |
| 156 | Taking down old unserviceable LT UG cable from any description (trenches, walls,ceilings., etc) from various locations, Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 25 Sq mm, 4.0 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified. |
| 157 | Supplying and laying in replacement of 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 158 | Supplying and fix ball valve of 25 mm dia CPVC complete all as specified. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail