| 1 | Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-XIV is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I. |
| 4 | Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II. |
| 5 | Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III. |
| 6 | Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS carried forward from Pre-Priced Schedule 'A' Part-IV. |
| 7 | Lump sum price worked out by the contractor for AREA DRAINAGE WORKS carried forward from Pre-Priced Schedule 'A' Part-V. |
| 8 | Lump sum price worked out by the contractor for PROTECTIVE WORKS carried forward from Pre-Priced Schedule 'A' Part-VI. |
| 9 | Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS carried forward from Pre-Priced Schedule 'A' Part-VII. |
| 10 | Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS carried forward from Pre-Priced Schedule 'A' Part-VIII. |
| 11 | Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-IX. |
| 12 | Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-X. |
| 13 | Lump sum price worked out by the contractor for DEMOLITION/DISMANTLING WORKS carried forward from Pre-Priced Schedule 'A' Part-XI. |
| 14 | Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-XII. |
| 15 | MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-XIV)(A) INTERNAL WATER SUPPLY WORKS |
| 16 | S & F of 15 mm bore Push Cock for urinal for iron pipe and fixed.( PRS-CHR-073) (Low-flow and flow Rate - 3.8 LPF) complete all as specified and as directed. |
| 17 | (B) INTERNAL ELECTRIFICATION WORKS |
| 18 | Supply and fixing of flame proof sheet metal enclosures MCB distribution DB AC Single pole & neutral 240 volts, 50 Hz 8 way withIP-43 IK-09 protection double door complete with 200 Amp bus bar and neutral link including cheses wall for fixing DB and making good disturbed wall surface to match with existing specification (ISI marked) complete all as specified and as directed. |
| 19 | (C) ROAD, PATH AND CULVERTS WORKS |
| 20 | Supply only Air Entraining agent confirming to IS 9103: 1999 and ASTM C260, complete all as specified and directed. Make: Sika/BASF/Fosroc |
| 21 | Supply only Curing compound confirming to ASTM C309 type II, Class A , complete all as specified and directed. Make: Sika/BASF/Fosroc |
| 22 | Supply only approved adhesive @ 0.5% by weight of cement for mixing in PQC, complete all as specified and directed. Make: Sika/BASF/Fosroc |
| 23 | (D) EXTERNAL ELECTRIFICATION WORKS |
| 24 | M&L for boring/cutting road suitable for inserting GI Pipe 40mm light grade with making good to be disturbed surface with PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, complete all as specified and directed. Note :- GI Pipe shall be measured and paid separately. |
| 25 | Supply, Intsallation testing, commissioning, design and fabricate cubical type LT Panel board of size (1.2mx1.0mx0.45m) outdoor type with CRCA sheet thickness not less than 3.15 mm, moisture and vermin proof provision of front and rear opening, cable gland hole, suitable looping busbar chamber for connecting out going cables-06 Nos) including 100 Amps rated aluminium bus bar colour coding all pre- wired with CT coils,seathed multistarnded copper conductor including the following and necessary PCC foundation to fix the panel board all as per standard specifications and CPRI approved specified as under and as directed by Engr-in-Charge.(i) Incoming MCCB 63 Amps, 25 KA, 4 pole 415 Volts,50 Hz - 01 No (ii) Outgoing MCB 32 Amps, DP - 02 Nos(iii) Volt meter 0-500 Volts with selector switch(RYB) digital type -01No (iv) Ampere meter 0-200 Amps with CTs & selector switch digital type -01 No (v) LED phase Indicator lamp (RYB) with switches–01 set Please Enable Macros to View BoQ information |