| 1 | Supplying and Fixing of polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).19 mm dia 3 mm thick Polythene Pipe [1(b)/E-2] |
| 2 | 25 mm dia 3 mm thick Polythene Pipe [1(c)/E-2] |
| 3 | Supplying & Fixing one way CI Round box with cover concealed in-ceiling/wall. [20(a)/E-6] |
| 4 | Supplying & Fixing two way CI Round box with cover concealed in-ceiling/wall. [20(b)/E-6] |
| 5 | S & F of Box type fan clamp of 150 mm dia & 80 mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12 mm dia 600 mm long MS rod duly bent by heat treatment at the centre position of the rod to grip the fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed to prevent concrete from entering the box. [31/D-14] |
| 6 | Cutting Channel of 40 mm x 40 mm on masonry wall by electrically operated cutting machine incl. S & F 19 mm dia 3 mm thick heavy gauge polythene pipe using anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackle. [6(a)/E-3 ] |
| 7 | Cutting Channel of 43 mm x 43 mm on masonry wall by electrically operated cutting machine incl. S & F 25 mm dia 3 mm thick heavy gauge polythene pipe using anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackles. [6(b)/E-3 ] |
| 8 | S & F of sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works.100 mm x 100 mm x 65 mm [11(a)/E-4] |
| 9 | 150 mm x 100 mm x 65 mm [11(b)/E-4] |
| 10 | 175 mm x 100 mm x 65 mm [11(c)/E-4] |
| 11 | Making 25 mm dia holes on a 125 mm depth RCC ceiling. [9(a)/E-3] |
| 12 | S & F of MS fan clamp of two-piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat, including making good damages to the building roof with satisfactory finishing and painting. [29/D-14] |
| 13 | S & F of 415 V, 125 A TPN SFU (Make - Siemens / L&K) with sheet steel enclosure on angle iron frame on the wall with nuts, bolts, etc., incl. S & F 3 nos. DIN type HRC fuse as per rating. [4(a)/D-3] |
| 14 | Supplying and fixing of 415 V and up to 160 A capacity MCCB incomer, 63 A SP/TP MCB outgoing, double door, 8-Way VTPN MCB DB (Make - Legrand/Schneider/ABB Itus/Siemens) with IP-43 protection on angle iron frame on wall & mending good the damages to original finish incl. interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. [15/D-11] |
| 15 | Supplying and fixing of 415 V, 32 A per way, double door, 4-way HTPN MCB DB with IP-43 protection (Make - Legrand/ Itus/Schneider/Siemens), concealed in the wall after cutting the wall & mending well the damages to original finish incl. interconnection with a suitable size of copper wire and neutral link & provision for earthing attachment. [14/D-10] |
| 16 | S & F of 240 V, 6 to16 A per way 2+10 Way double-door SPN MCB Distribution Board (Make - Legrand / Siemens/ ABB Itus / Schneider) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. [13/D-10] |
| 17 | S & F of the single door 240 V, 2-way SP MCB SS enclosure (powder coated) with IP-43 protection (Make - Legrand/Schneider/ABB/Siemens), concealed in the wall after cutting the wall & mending well the damages to the original finish incl. connection & provision for earthing attachment. [11/D-9] |
| 18 | Distribution wiring in 1.1 KV grade, 3 x 1.5 sq. mm, 'FR' PVC insulated & unsheathed, single core, stranded copper wire (Brand - Finolex / RR Kabel / Havells) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fanpoints with switch (Anchor make) fixed on sheet metal (16 SWG) switchboard in wall complete with 3 nos. suitable size “Ph, N & E” copper bar incl. bakelite top cover (3 mm thick) incl. 175 mm x 100 mm x 65 mm inspection box, making an earthing attachment, painting the MS box and mending the damages to the original finish. The polythene pipe in the ceiling portion should be laid after the wood shuttering work and before the roof casting. Average run - 9 Mtr. [2(a)(v)/E-9] |
| 19 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand - Finolex / RR Kabel / Havells) partly in 20 mm size MMS PVC rigid conduit (Make - Precision) for ceiling portion only and in 19 mm bore, 3 mm thick polythene pipe for horizontal & vertical run embedded in wall to light/fan/call bell points with Switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switchboard in wall complete with 3 nos. suitable size “Ph, N & E” copper bar incl. bakelite top cover (3 mm thick) incl. 175 mm x 100 mm x 65 mm inspection box, making an earthing attachment, painting the MS box and mending the damages to the original finish (only PVC Rigid Conduit on the ceiling and the remaining portion concealed). Average run - 9 Mtr. [5(e)/E-15] |
| 20 | Distribution wiring in 1.1 KV grade 3 X 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand - Finolex / RR Kabel / Havells) in 20 mm size MMS PVC rigid conduit (Make - Precision)on wall surface to light/fan/call bell points with switch (Anchor) fixed on MS CRC sheet metal (16 SWG) switchboard complete with 3 nos. suitable size “Ph, N & E” copper bar incl. bakelite top cover (3 mm thick) flushed in wall and 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box, mending well the damages to original finish - Average run 9 Mtr. [2(e)/E-14] |
| 21 | Distribution wiring in 1.1 KV grade 3 x 1.5 sq. mm single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand - Finolex / RR Kabel / Havells) to 6 A flush type plug socket & switch fixed on MS CRC sheet metal switchboard (16 SWG) embedded in wall complete with 3 mm thick bakelite top cover, painting the MS box and mending good the damages to original finish - On Board. [4(a)(i)/E-10] |
| 22 | S & F of 240 V, 6 A plug socket - 3 nos. with separate 6 A switch (Anchor) - 3 nos. on SM switchboard, embedded in wall, incl. S & F 200 mm x 150 mm x 65 mm MS (16 SWG) switchboard and bakelite top cover of 3 mm thick by brass screws after making housing for the switch by cutting the bakelite cover and making necessary connections as required. [10(c)/E-4] & [14 (a),15(a)/E-5] |
| 23 | S & F of 240 V, 20 A plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switchboard embedded in wall incl. S & F 150 mm x 100 mm x 65 mm MS (16S WG) switchboard and bakelite/perspex top cover of 3 mm thick by brass screws after making housing for the switch by cutting bakelite/perspex cover and making necessary connections as required. E-6/22 |
| 24 | S & F of 240 V, 3 nos. 6 A & 1 no 20 A plug socket with separate 3 nos. 6 A & 1 no. 20 A piano key type switch with indicator & 16 A kit-kat fuse unit (Anchor) on sheet metal switch board embedded in wall incl. S&F of 240 mm X 200 mm X 65 mm MS (16 SWG) switch board and bakelite top cover of 3 mm. thick by brass screw and making necessary connection as required. E-7/25 |
| 25 | Supplying and drawing 1.1 KV Gr. single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand - Finolex / RR Kabel / Havells) of the following sizes in the pre-laid polythene pipe as per GS.3 x 1.5 sq. mm [1(b)/E-9] |
| 26 | 2 x 2.5 sq. mm + 1 x 1.5 sq. mm [1(s)/E-9] |
| 27 | 2 x 6 sq. mm + 1 x 4 sq. mm [1(y)/E- 9] |
| 28 | 4 x 16 sq. mm + 2 x 10 sq. mm [1(g1)/E- 9] |
| 29 | S & F of bakelite / perspex top cover on existing inspection board by brass screws --100 mm x 100 mm x 65 mm [12(a)/E-5] |
| 30 | 150 mm x 100 mm x 65 mm [13(b)/E-4] |
| 31 | 175 mm x 100 mm x 65 mm [13(c)/E-4] |
| 32 | Supplying and delivering the Armoured Cables with XLPE/PVC insulated, designed for 1.1 kV Gr., Stranded Aluminium Conductor, high tensile galvanised steel wire/strip armour for mechanical protection and PVC/FR PVC outer sheathing power cable (Make - Havells / Universal / RR Kabel) of the following sizes as per IS 7098 Part - 1/2011 with up-to-date amendments ----4 core 6 sq. mm |
| 33 | 4 core 70 sq. mm |
| 34 | Supplying & fixing of 50 mm dia medium gauge GI pipe (Make - Jindal/Bansal) protection with necessary fittings and jointing materials as required. [11(d)/F-6] |
| 35 | Cutting below the Pacca/Concrete Road with necessary tools & tackles for installation of 50 mm dia GI pipe, including filling the vacant space between pipe and road with soil and mending the damages as per the direction of EIC. |
| 36 | Laying of the following cables on the wall/surface incl. S & F MS saddles/clamps with earthing attachment in 10 SWG GI (Hot-Dip) Wire, making holes etc. as necessary mending good damages and painting. 4 core 6 sq. mm. [2(b)/F-1] |
| 37 | 4 core 70 sq. mm cable. [2(d)/F-1] |
| 38 | Laying of following sizes cables after cutting floor/pavement/wall and making holes incl., including embedding the cable at an average depth as below and mending well the damages to original finish incl. removing the rubbish ------4 core 6 sq. mm at an average depth of 75 mm in floor/pavement/wall, etc. [5(i)/F-3] |
| 39 | 4 core 70 sq. mm at an average depth of 100 mm in floor/pavement/wall etc. [5(ii)/F-3] |
| 40 | Laying of one no. 4 core 70 sq. mm cable in the underground trench of 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) nos. bricks per metre, including filling the space between the bricks and cable and also the trench with shifted soil, levelling up and restoring surface duly rammed. [1(b)/F-2] |
| 41 | Laying of 4 core 70 sq. mm cable through existing GI Pipe / open masonry trench. [3(b)/F-2 ] |
| 42 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of the following XLPE/PVC armoured cables as below :4 core 6 sq mm [7(c)/F-4] |
| 43 | 4 core 70 sq. mm [7(c)/F-4] |
| 44 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core 6 sq. mm cable [8(b)(x)/F-5] |
| 45 | 4 core 70 sq. mm cable [8(b-xvii)/F-5] |
| 46 | Excavation of soil for the installation of Earth Electrode with filling & ramming for soft soil. [1(a)/G-1] |
| 47 | Earthing with 50 mm dia GI pipe (Tata Medium), 3.64 mm thick x 3.04 Mt. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mt. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mt. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mt. below the ground level. [2(a)/G-1] |
| 48 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2)] |
| 49 | S & F of earth busbar of galvanised (Hot Dip) MS flat 40 mm x 6 mm on the wall, having clearance of 6 mm from the wall, including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators, etc. as required. [4(b)/G-2] |
| 50 | Connecting the equipment's body to the earth busbar, including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required, and connection to the equipment, including drilling holes, with bolts, nuts, washers, etc. [5(d)/G-3] |
| 51 | Supplying and fixing 415 V, 125 A FP MCCB of breaking capacity 36 kA with adjustable thermal and fixed magnetic setting in VTPN DB and necessary connection. (Make - Legrand / ABB / Schneider). [10/D-8] |
| 52 | Supplying and fixing 240/415 V, 6/10/16/20/25/32 A SP/DP/TP/FP MCB of breaking capacity 10 kA & C characteristics (Make - Legrand / Siemens / Schneider) on din rail of VTPN, HTPN and SPN DBs and necessary connections. [7/D-6]240 V, 16/20/25/32 A SP MCB |
| 53 | 240 V, 20/25/32 A DP MCB |
| 54 | 415 V, 63 A TP MCB |
| 55 | 415 V, 63 A FP MCB |
| 56 | Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [9/F-5]2 x 2.5 sq. mm + 1 x 1.5 sq. mm |
| 57 | 2 x 6 sq. mm + 1 x 4 sq. mm [1(y)/E- 9] |
| 58 | 4 x 16 sq. mm + 2 x 10 sq. mm |
| 59 | Supply of box type, 4 ft. long, single T-8 LED tube light fittings complete with all accessories [Make - Phillips, Cat No. - TMC 502 P 1 x T-LED 22 W / Wipro, Cat No. WIO912208]. [NS] including |
| 60 | Supply of 4 ft. long 18/20 Watt, polycarbonate LED T-8 lamp (Make - Philips Master LED tube model no. 18W 865 T8 I 2100 lm / Wipro, Cat No. LL13-181-65SESL/ Crompton]. [NS] |
| 61 | Supply & delivery of 230 V, 50 Hz, single phase, 58 watts, 56\\" (1400 mm) Sweep, speed 300 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019. (Usha/Orient/Crompton with P2 Capacitor |
| 62 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts, 9\\" (230 mm) sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9, and a minimum air delivery of 650 cmh (minimum), including a capacitor with a safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohms, suitable for compliance with IS 374:2019.(EPC) |
| 63 | Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Air-Circulator adjustable Pedestal Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and a minimum air delivery of 110 cu.m/min (minimum), including a capacitor with safety pin, nut bolts, washers, temperature rise=75 degrees C (max.), insulation resistance more than 2 megohms, suitable for Compliant to IS 374:2019 and external connections with 1.5 sq. mm FR, PVC insulated copper conductor single core cable and earthing, etc., as required. (EPC/Crompton/Usha) |
| 64 | SITC of 120 Watt Street light LED fixture powder coated pressure die cast aluminium body finish with corrosion-resistant fasteners (SS hardware) & silicon gasket for proper sealing with the driver as per the requirement, with the driver efficiency >80%, Input Voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0 ° to 50 ° C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L, N, E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than the lamp rating, and at least 2 drivers for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and overvoltage protection, a high-efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not be more than the specified rating, and the fixture shall be of the relevant BIS standard, complete in all respects, and LED Chips of SMD mid to high-power (2.5 to 4 watts for 200 watts and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 5 years OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test reports, except L80, should be from a 3rd-party NABL-accredited lab, as per BIS, and shall be submitted. Shape size and CCT shall be as approved by the Engineer-in-Charge as per the requirements. System lumen efficacy ≥135 lm/Watt. (Philips/Wipro/Crompton) |
| 65 | SITC of 150 Watt Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L, N, E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating & and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 5700°K /6000°K/6500°K, Maximum power consumption should not be more than the specified rating, and Fixture shall be of relevant BIS standard complete in all respects and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc., as required with minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test reports, except L80, should be from a 3rd-party NABL-accredited lab as per BIS, and shall be submitted. Shape size and CCT shall be as approved by the Engineer-in-Charge as per the requirements. System lumen efficacy shall be as below: 7.1 System lumen efficacy ≥135 <135 lm/Watt (Philips/Wipro/Crompton) |
| 66 | Fixing only single / twin LED light fitting suspended 25 cm bellow the ceiling with 2 nos. 20 mm dia EI conduit (16 SWG) supports fixed with “L” type (100 +75) mm x 25 mm x 3 mm thick MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size 4 nos nut-bolt and making connection by PVC insulated stranded copper wire (3 x 1.5 sq. mm up to 1 mt. length through the polythene pipe) with mending good damages to original finish incl. S&F the fixing materials, panting etc as required. NS |
| 67 | S & F additional 2 nos. 20 mm dia EI conduit (16 SWG) supports, PVC insulated stranded copper wire (3 x 1.5 sq. mm through the polythene pipe) & panting etc as required for extra suspension of fitting exceeding 25 cm. NS |
| 68 | Fixing only 225 cm (9\\") exhaust fan after making holes in the wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making the connection. [28(a)/C-4] |
| 69 | S & Fixing Al. louver shutter/cowl for 225 cm (9\\") dia exhaust fan on the wall with necy. bolts & nuts (6 mm dia x 62 mm long). [30(a)/D-14] |
| 70 | Making of a 9-inch diameter round shape iron grill made from 25 mm x 3 mm flat iron to be fixed on the outside wall, in front of the hole for the exhaust fan, including mending the damages as required. |
| 71 | Fixing only outdoor type LED light fitting complete with all accessories to be fixed/projected from the wall of the building by making holes, providing clamping arrangement, S&F 40 mm dia and 1.5 Mtr. long GI pipe (ISI-Medium) having suitable bend, necy. GI reducer, making connections with 3 core 1.5 sq. mm PVC insulated stranded copper cable from loop box, mending good damages to wall incl. painting etc. as required. [18/C-3] |
| 72 | Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure. [20(a)/C-3]. |
| 73 | S & F of 1.20 mm (18 SWG) thick, GI waterproof type looping cable box (200 mm x 150 mm x 100 mm deep) comprising of one 240 V, 16 A kit-kat fuse unit, 4 nos. 16 A stud type connectors, hinged top cover with rubber gasket and mechanical locking arrangement, earthing terminal with the lug etc. on the pole above the muffing with S&F 2 nos. flat iron clamp sets made with 20 mm x 3 mm thick flat iron bar with nut-bolt etc. suitable for fixing above-mentioned loop box on the pole including painting with anticorrosive paint. (H5/5) |
| 74 | S&F of Philips GreenLED Ultima Square surface mounted LED downlight complete with all accessories suspended from ceiling with all accessories (Philips: SM25C LED 12S-6500 PSU WH or Crompton-LCDSPLN-S-12 CDL) |
| 75 | Supply of 240 V, BC type 12 W LED lamp to the lamp point [Make - Philips/ Wipro/ Crompton]. |
| 76 | Supplying & fixing socket and step type electronic Fan Regulator (Anchor make) on existing sheet metal switchboard with bakelite top cover by screws after making housing for regulator knob by cutting bakelite top cover including making necessary connections etc. [18(a) /E-6] Please Enable Macros to View BoQ information |