| 1 | Dismantling of ACSR or AAC conductors and removing old material from site for taking credit. |
| 2 | Dismantling insulators any type, any size and revoming old material from site for taking credit |
| 3 | Dismantling cross arms of MS channel or angle sections etc complete and removing old material from site for taking credit |
| 4 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable all as specified and directed by Engr in charge as in |
| 5 | (a) Soft/loose soil |
| 6 | (b) Hard/dense soil |
| 7 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified. |
| 8 | Removal of surplus excavated soil to distance n exc 50 metre all as specified and directed |
| 9 | M & L for bituminous road cutting to a width of 30 cm and depth 45 cm length up to 6 mtr for laying of pipe for laying of UG cables and making good with PCC (1:3:6) type cI (using 20mm grade stone aggregate) |
| 10 | Supplying and laying GI tubing light grade of size 50mm dia bore for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed by Engr-in-charge. |
| 11 | Supply , laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc incl connection with proper sizes lugs and gland, suitable clamp of cross sectional area 4 core 25 Sqmm |
| 12 | All as per item 9 above but of the size 3.5 core 50 Sqmm |
| 13 | All as per item 9 above but of the size 3.5 core 70 Sqmm |
| 14 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified. |
| 15 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified. |
| 16 | Supplying and laying GI tubing Light grade of size 32 mm dia bore for encasing cables for mechanical protection , laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed by Engr-in-charge. |
| 17 | M&L PCC(1:3:6) type C-1 using 20mm graded broken stone aggregates as in foundadion filling and mass concrete ( for coping above ground level in stay poles or any other directed site ) including Dismentaling of old PCC of any type complite all as specific and directed by Engr-in-Charge. |
| 18 | M & L and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed 410-SP-22 ( 8.5 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms /Service bracket, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc complete . |
| 19 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box IP 65, out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 30 cm below ground level and 40 cm above ground level suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with ALDRAF LOCKING ARRANGEMENT, consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.0 x 0.8 x 0.5 Mtr (approx) and with danger sign board on the outside door including connecting the following:- Location - Near Officer mess 108 Engr Regt |
| 20 | (a) Aluminium bus bar rectangular 400 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b) MCCB 160 Amps, 4 Pole, 415 Volts, 50 Hz , 35 KA Ics=100% Icu - 01 No ( Incoming) (c) MCCB 100 Amps, 4 Pole, 415 Volts, 50 Hz , 25 KA Ics=100% Icu - 02 No ( Outgoing) (d) MCCB 32 Amps, 4 Pole, 415 Volts, 50 Hz , 16 KA Ics=100% Icu - 01 No ( Outgoing) (e) RYB LED Indicator Lamp- Set of Three-01(f) Volt meter 0-500 Volt with selector switch(g) Amp meter 0-600 Amp with selector switch with CT-03 Nos(h) Three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil - 01 N0(k) Digital timer switch with inbuilt backup current capacity 16 Amps operated on 415 volts AC 50Hz, - 02 No(i) Provision of cubicle to accommodate the above mentioned accessories.(j) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 21 | Supply, installation, testing and commissioning weather and vermin proof factory made CPRI approved LT feeder pillar box IP 65, out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 30 cm below ground level and 50 cm above from ground level, suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with ALDRAF LOCKING ARRANGEMENT, consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.0 x 0.8 x 0.5 Mtr (approx) and with danger sign board on the outside door including connecting the following:- Location - Near 108 Engr Regt Sub Stn ARN Road |
| 22 | (a) Aluminium bus bar rectangular 200 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b) MCCB 100 Amps, 4P, 415 Volts, 50 Hz , 25 KA Ics=100% Icu - 01 No ( Incoming) (c) MCCB 63 Amps, 4P, 415 Volts, 50 Hz , 16 KA Ics=100% Icu - 02 No ( Outgoing) (d) MCCB 32 Amps, 4P, 415 Volts, 50 Hz , 16 KA Ics=100% Icu - 02 No ( Outgoing) (e) RYB LED Indicator Lamp- Set of Three-01(f) Volt meter 0-500 Volt with selector switch(g) Amp meter 0-600 Amp with selector switch with CT-03 Nos(h) Three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil Make - 02 N0(k) Digital timer switch with inbuilt backup current capacity 16 Amps operated on 415 volts AC 50Hz, - 02 No(i) Provision of cubicle to accommodate the above mentioned accessories.(j) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable |
| 23 | M & L for fabrication of junction box of Size 250X200X100 made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 10 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex. |
| 24 | S&F of PVC insulated cable with copper condcutor 1.5 sqmm three core drwan through pole from pole junction box to street light connector and testing complete. |
| 25 | M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iton strip of 25 x 4 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 CM made of RCC 1:3:6 with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site all as specified in plate No 3 of SSR Part-I and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |