| 1 | Dismantling of old unserviceable ACSR/AAC conductor from poles and keep in safe custody & handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 2 | Dismantling cross-arms of MS channel or angle sections etc fro poles complete and setting aside safely for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 3 | Dismantling insulator any type and capacity and setting aside safely for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 4 | Dismantling steel poles/struts any size and setting aside for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 5 | Dismantling and taking down HPSV/HPMV/CFL street light fittings of any size and setting aside for for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 6 | Dismantling and taking out old unserviceable XLPE cable any size alongwith DWC pipe and setting aside for for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 7 | Dismantling stay assembly complete(demolition of concrete etc and removing old unserviceable material from site for for handing over to contractor on account of schedule of credit complete all as specified and directed by Engineer-in-Charge. |
| 8 | M & L and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed steel surfaces and two coats of black bituminous paint for portion embedded in concrete, etc complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply , laying connecting and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade in trenches/ passing through pipe/fixing on walls, floors etc including using suitable clamp of cross sectional area 2 core 10 Sqmm Sqmm complete all as specified and directed by Engineer-in-Charge.Note : excavation & earthwork shall be measured and paid seperately. |
| 10 | All as per item 9 above but of the size 4 core 25 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 11 | All as per item 9 above but of the size 3.5 core 120 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed by Engineer-in-Charge. |
| 14 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and making good surface for laying /removing of cable complete all as specified and directed by Engineer-in-Charge. |
| 15 | Soft/loose soil |
| 16 | Hard/dense soil |
| 17 | Excavation in trenches exceeding 1.5m wide and n exc. 3 m in depth for pole foundation/laying cables in Soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge. |
| 18 | Returning filling in excavated soil in trenches, watering and well ramming in layers n exc 25 cm complete all as specified and directed by Engineer-in-Charge. |
| 19 | Removal of surplus excavated spoil to distance n exc 50 metre complete all as specified and directed by Engineer-in-Charge. |
| 20 | M & L for Plain Cement Concrete 1:4:8 type D2 using 40 mm graded stone aggregate nominal mix for plinth blocks of LT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for Plain Cement Concrete 1:3:6 type C1 using 20 mm graded stone aggregate nominal mix for coping of poles including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 22 | M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe for laying of UG cables and making good with Plain Cement Concrete (1:3:6) type C1 (using 20mm grade stone aggregate) complete all as specified and directed by Engineer-in-Charge.Note : Laying of cable/pipes shall be measured and paid seperately. |
| 23 | M & L for GI tubing light grade ISI marked with including all fittings for protection of cable laid in tranches or fixing to pole ducts/road crossing/on wall with suitable size of FI clamp complete of the following sizes :- |
| 24 | 40mm dia bore |
| 25 | 50mm dia bore |
| 26 | Supply and fixing LED street light fitting 70 watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F of PVC insulated cable with copper condcutor 1.5 sqmm three core drwan through pole from pole junction box to street light connector and testing complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F street light bracket made out of 40mm dia light grade GI pipe of 1.5metre long bend to shape including pole bracket made out of MS strip 40x5 mm flat, nut bolts, washers etc and fixed on wall/pole complete all as specified and directed by Engineer-in-Charge. |
| 29 | M & L for fabrication of PVC junction box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one number of MCB (SP) 10 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and directed by Engineer-in-Charge. |
| 30 | M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25m below normal ground level with top edge of the earth plate not less than 1.5m deep below normal ground level connected to galvanised iron strip 32 x 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC 1:3:6 type C1 earth chamber of outer dimension 54 x 54 x 30 cm and internal diamension 30 x 30 x 30 cm with RCC 1:2:4 type B1 cover reinforced of size 54 x 54 x 10cm with 6mm dia mild steel round bar @ 15cm c/c both way and 8 mm dia mild roud bard handle adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site all as specified in plate No 3 of SSR Part-I complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply, installation, testing and commissioning in replacement weather and vermin proof factory made CPRI approved LT feeder pillar box,IP65 out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above round suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and Aldrop locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.8 x 1.5 x 0.6 Mtr (approx) including connecting the following:- Location (SS-4) |
| 32 | (a) Aluminum bus bar rectangular 800 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b) MCCB 4 pole 630 A thermal magnetic release, adjustable type, 50 kA,ICS=100%ICU - 01 No (I/C)(c) MCCB 4 pole 400 A thermal magnetic release adjustable type, 36 kA ,ICS=100%ICU- 02 No (O/G)(d) MCCB 4 pole 200 A thermal magnetic release, adjustable type, 25 kA,ICS=100%ICU- 01 No (O/G )(e) MCCB 4 pole 100 A thermal magnetic release,adjustable type, 16 kA,ICS=100%ICU-02 No (O/G )(f) MCCB 4 pole 63 A thermal magnetic release, adjustable type, 16 kA,ICS=100%ICU-01 No (O/G)(g) MCCB 4 pole 32 A thermal magnetic release adjustable type, 16 kA,ICS=100%ICU - 01 No (O/G) |
| 33 | (h) Three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil - 01 No(i) Digital timer switch with inbuilt backup operated on 415 volts AC 50Hz, - 01 No(j) Digital volt meter 0-500 V -1 No(k) Digital ammeter 0-600 Amps - 1 No (l) Phase indicator lamp LED Type - 1 Set (m) MCB SP 6-32A - 03 No (for street light phase separation)(n) Provision of cubicle to accommodate the above mentioned accessories. (o) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 34 | Supply, installation, testing and commissioning in replacement weather and vermin proof factory made CPRI approved LT feeder pillar box,IP65 out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above round suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and Aldrop locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.2 x 1 x 0.6 Mtr (approx) including connecting the following:- Location (Near hockey ground) |
| 35 | (a) Aluminum bus bar rectangular 500 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b) MCCB 4 pole 315 A thermal magnetic release, adjustable type, 36 kA,ICS=100%ICU- 01 No (I/C)(c) MCCB 4 pole 250 A thermal magnetic release, adjustable type, 25 kA,ICS=100%ICU- 01 Nos (O/G)(d) MCCB 4 pole 100 A thermal magnetic release, adjustable type, 16 kA,ICS=100%ICU- 01 Nos (O/G)(e) MCCB 4 pole 63 A thermal magnetic release, adjustable type, 16 kA,ICS=100%ICU-01No (O/G) |
| 36 | (f) Digital volt meter 0-500 V -1 No (g) Digital ammeter 0-600 Amps - 1 No (h) Phase indicator lamp LED Type - 1 Set(i) Provision of cubicle to accommodate the above mentioned accessories.(j) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 37 | Supply, installation, testing and commissioning in replacement weather and vermin proof factory made CPRI approved LT feeder pillar box, IP65 out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above round suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and Aldrop locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.5 x 1.2 x 0.6 Mtr (approx) including connecting the following:- Location (Near Lake) |
| 38 | (a) aluminium bus bar rectangular 500 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b MCCB 4 pole 315 A thermal magnetic release adjustable type, 36 kA ,ICS=100%ICU- 01 No (I/C)(c) MCCB 4 pole 250 A thermal magnetic release, adjustable type, 25 kA,ICS=100%ICU- 01 Nos (O/G)(d) MCCB 4 pole 100 A thermal magnetic release, adjustable type, 25 kA,ICS=100%ICU- 02 No (O/G for FP-435 & spare)(g) Digital volt meter 0-500 V -1 No |
| 39 | (h) Digital ammeter 0-600 Amps - 1 No(j) Phase indicator lamp LED Type - 1 Set (k) Provision of cubicle to accommodate the above mentioned accessories.(l) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. |
| 40 | Supply, installation, testing and commissioning in replacement weather and vermin proof factory made CPRI approved LT feeder pillar box,IP65 out door cubicle/KIOSK type totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm grouted in CM, 45 cm below ground level and 60 cm above round suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and Aldrop locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminum bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set, size 1.8 x 1.2 x 0.6 Mtr (approx) including connecting the following:- Location (Near bhosari gate) |
| 41 | (a) Aluminium bus bar rectangular 400 Amps full for phase and half for neutral mounted on epoxy insulators with colour coding PVC sleeves.-01 job(b) MCCB 4 pole 250 A thermal magnetic release, adjustable type, 25 kA,ICS=100%ICU- 01 No (I/C)(c) MCCB 4 pole 100 A thermal magnetic release, adjustable type, 16 kA,ICS=100%ICU-02 No (O/G)(c) MCCB 4 pole 63 A thermal magnetic release, adjustable type, 16 kA,ICS=100%ICU-02 No (O/G)(d) Digital volt meter 0-500 V -1 No (e) Digital ammeter 0-600 Amps - 1 No |
| 42 | (f) Phase indicator lamp LED Type - 1 Set (g) Provision of cubicle to accommodate the above mentioned accessories. (h) Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable. Please Enable Macros to View BoQ information |