| 1 | SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 2 | Construction of married accn for SGT and below three storey (G+2) block of 06 Qtrs complete all as specified and as shown on drawings. |
| 3 | Construction of garrages for block of three (03) cars and three (03) scooter single storey including ramp complete all as specified and as shown on drawings. |
| 4 | Construction of service toilet single storey complete all as specified and as shown on drawings. |
| 5 | Construction of pump house building complete all as specified and as shown on drawings. |
| 6 | Construction of under ground sump, 25000 ltr capacity complete all as specified and as shown on drawings. |
| 7 | NOTE: Schedule ‘A’ Part II to XVI under Ser No 2.01 to 2.15 are Prepriced by MES. |
| 8 | Lump sum price worked out by the Contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II |
| 9 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part III |
| 10 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION SUPPLY\\" as listed in Schedule ‘A’ Part IV |
| 11 | Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT\\" as listed in Schedule ‘A’ Part V |
| 12 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part VI |
| 13 | Lump sum price worked out by the Contractor for “AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Part VII |
| 14 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part VIII |
| 15 | Lump sum price worked out by the Contractor for “HOT WATER SUPPLY” as listed in Schedule ‘A’ Part IX |
| 16 | Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING\\" as listed in Schedule ‘A’ Part X |
| 17 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part XI |
| 18 | Lump sum price worked out by the Contractor for “DG SET WORKS” as listed in Schedule ‘A’ Part-XII |
| 19 | Lump sum price worked out by the Contractor for “CHILDREN PARK WORK” as listed in Schedule ‘A’ Part-XIII |
| 20 | Lump sum price worked out by the Contractor for “VERMICOMPOST WORK” as listed in Schedule ‘A’ Part-XIV |
| 21 | Lump sum price worked out by the Contractor for “GRASS PAVER WORK” as listed in Schedule ‘A’ Part-XV |
| 22 | Lump sum price worked out by the Contractor for “ARBORICULTURE WORK” as listed in Schedule ‘A’ Part-XVI |
| 23 | SCHEDULE `A' PART - XII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only. |
| 24 | “INTERNAL ELECTRIC SUPPLY\\" |
| 25 | Supply and fix blank plate one module complete all as specified and directed by Engr in Charge. |
| 26 | Supply and fixing Metal flush box 8 module complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fix, LED bulb 7 Watt, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fixing LED building security light fitting 25 Watt 230 V AC outdoor type with high-pressure die-cast aluminum housing and heat-resistant complete with driver, lamp bracket with impact and corrosion-resistant, including thermal management in multiple optics, complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and fix TV coaxial connector type F-1 modular design for cable installation of white colour combines functionally with a sleek design complete all as specified and directed by Engineer-in-charge. |
| 30 | \\"EXTERNAL WATER SUPPLY\\" |
| 31 | Supply, laying, jointing & testing 65mm bore Steel tubes 'medium grade', ISI marked galvanized with all fittings, laid in trenches or fixed to wall, complete all as specified and directed by Engr in Charge. |
| 32 | Supply & fix Foot valve of size 65 mm Kirloskar Make, IS 4038, Cat No. CI FOOT VALVE (IS1538 T-4 & 6), PN0.2 Flg FF IS 1538 Tbl 486, (or equivalent model of approved make) Cast Iron BODY, Cast Iron Door, complete all as specified and directed by engineer in charge. |
| 33 | S&F Monoblock electric driven pump and install complete upto 2 HP, 3 phase, 415V, size 40×50 mm, flatter efficiency curve and wide voltage design, dynamically balanced rotating parts, design to prevent overloading and inclusive of starter and foundation and complete all as specified and directed by engineer in charge. (1 working and 1 standby) |
| 34 | M&L masonry valve pit of size 900×600×1000 mm (internal size) PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation, brick wall with sub class ‘B’ bricks built in CM 1:6 PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping rendering in CM (1:4), 15 mm thick including provision of MS sheet cover 2 mm thick fixed to MS angle frame made out of 50×50×6 mm thick with 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and locking arrangements including dismantling old one with necessary excavation and earth work in any type of soil complete, complete all as specified and directed by engineer in charge. |
| 35 | M&L masonry valve pit of size 450×450×600 mm (internal size) PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation, brick wall with sub class ‘B’ bricks built in CM 1:6 PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping rendering in CM (1:4), 15 mm thick including provision of MS sheet cover 2 mm thick fixed to MS angle frame made out of 50×50×6 mm thick with 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and locking arrangements including dismantling old one with necessary excavation and earth work in any type of soil complete, complete all as specified and directed by engineer in charge. |
| 36 | Supply and fix Tee of size 150/100 of DI suitable at site and complete all as specified and directed by engineer in charge. |
| 37 | M&L for cutting existing CI/DI pipe line of 150 mm dia in situ for taking branch connection of 100 mm dia in position using DI/GI special fittings of required size like, flanged tee/socketed tee/socketed/spigot tail piece of suitable size including necessary earthwork, complete all as specified and directed by engineer in charge. Note: DI/GI special fittings shall be measured and paid separately under relevant item. |
| 38 | M&L for boring holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine or by using manual manpower and boring tools including passing HDPE casing pipe of dia 150 mm and passing water pipe line GI/MS pipe upto 100/63/50 mm dia, using welded/socketed joints under roads/hardstandings/floors etc, complete all as specified and directed by engineer in charge. Note 1: Any damage to existing electric cables/telephone/signal cable/water/gas pipe line during boring under roads/floors shall be rectified by the contractor at his own cost without any delay within 24 hours to avoid affect on services.Note 2: MS/GI Pipe shall be measured and paid separately under relevant items of work. |
| 39 | \\"RAIN WATER HARVESTING\\" |
| 40 | M&L for drilling 200 mm dia bore holes by DHT cum rotary method at any depth in any type of soil upto 40m depth from natural ground level and including removal of surplus soil to a distance not exc 50m complete all as specified and as directed (Trial bores of 200mm dia upto 200 mtr depth below ground level if any kind of soil strata incl. hard stone/ boulder incl. elec loging, MS cap, MS plate iron clanf reducing socket etc.) complete all as specified and directed by engineer in charge. |
| 41 | M&L for RCC NP3 pipe 200mm dia laid on 150mm thick PCC bed 1:4:8 (Type D2) with excavation including manholes and complete sewer line functional complete all as specified and directed by engineer in charge. |
| 42 | M&L PVC pipe 200mm dia of pressure rating 6 Kg/Sqcm laid in recharge pit all as specified and directed complete all as specified and directed by engineer in charge. |
| 43 | M&L PVC perforated pipe 200mm dia of pressure rating 6 Kg/Sqcm laid in recharge pit complete all as specified and directed by engineer in charge. |
| 44 | \\"EXTERNAL ELECTRIC SUPPLY\\" |
| 45 | Supply, installation, testing & commissioning of 11kV, 630 Amps, 21KA/3 sec. Non-Extensible Ring Main Unit indoor type Compact switchgear consisting of 1 nos. fixed motorized Vacuum Circuit Breaker Module and 2 Nos. fixed motorized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C × 3R 95 sq.mm Aluminium XLPE cable. - 1 No.(a) Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 compliant). (b) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (c) SF6 Gas pressure indicator. (d) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO. (e) CT shall be minimum 40/1-1A, 2.5VA, core-1 is 0.5 & core 2 is 5P20 - 3 nos. (f) Single Phase Bus PT 11000V/1.732/110V/1.732, Class 0.5, Burden: 10VA - 3 nos. (g) 2×12V, 26AH Battery with Dual Charger - 1 Set. (h) Multifunction Meter with RS485 port for reading Amp, Volt, PF, Hz, KWAH, KVARH, KW, KVA, KVAR. (j) All modules of the RMU shall be suitable for cable termination of 3C × 95 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set, Incoming-01 Nos & outgoing-02 Nos. Complete all as specified and directed by engineer in charge. |
| 46 | Supply, installed, commissioning and testing of outdoor type LT panel board of Suitable Size according to Incoming and Outgoing MCCB, outdoor cubical type kiosk. Factory made (CPRI approved) double door type on front & back side openable with locking arrangement, main panel board fabricated out of CRCA MS sheet 3.15 mm Thick, 50×50×6 mm angle iron and Tee-section frame, dust and vermin proof. Complete with Aluminium bus bar 4 Nos 250 Amps capacity in horizontal position mounted on porcelain insulators, totally enclosed, chamber for protection 3 phase 440 volt with suitable size of PVC insulated copper cable control wiring duly mounted on IPCC (1:2:4) foundation/platform of height 450mm with suitable size of bolts, nuts & washers. The panel board shall be Powder coated with synthetic enamel paint over a coat of red oxide zinc chrome primer complete including the following, complete all as specified and directed by engineer in charge. (i) Incoming MCCB 415 volts, 4 pole 25 KA 200 Amps – 01 Nos (ii) Outgoing MCCB 415 volts, 4 pole 16 KA 125 Amps – 06 Nos. (iii) Digital Volt meter 0-500 volt – 01 Nos. (iv) Amp meter 0-500 Amps with in-built CT’s and selector switch – 01 set also with three phase indicating lamp. (v) Three Phase Road light timer + Contactor 40 Amp + MCB TP 40 Amp – 01 Nos. |
| 47 | S&F SMC based outdoor type junction box pole hinged (L) mounted having four Nos Aluminium bus bar of suitable size for cable connection and looping including MCB SP 06 Amps, C curve, 10KA, fixed to pole/wall with necessary clamps, nuts, bolts, etc., complete all as specified and directed by engineer in charge. |
| 48 | Supply & fixing Cable route indicator for LT cable, made out of CI circular shape 150mm dia, 3mm thick with engraved letter “MES LT CABLE” with provision of 500 mm long, single leg stand of angle iron 40×40×5mm, welded/riveted on back side of plate, fixed and grouted in position with PCC(1:3:6), type C-1, concrete block of size (150×150×200mm) including painting path indicator & exposed surfaces of angle iron with two coats of aluminium paint and fixed along the route of LT cable one each after every 50-60 mtr distance/turning points complete all as specified and directed by Engg in chrg. |
| 49 | Supply and fixing Steel wire re-inforced factory made cement concrete type B1 (1:2:4) (20 mm graded aggregate) in precast cable route indicator of size 600×450×50 mm rounded top and duly engraved Danger “SKELETON” Symbol on top side and below engraved in capital letters in three lines as in 1st line “DANGER”, 2nd line “MES 11KV”, 3rd line “HT CABLE”. The complete slab painted in white synthetic paint, engraved “SKELETON” in red color and engraved letters in Yellow color complete as directed and grouting in ground with PCC type C-1, block of appx size one cubic Feet along the route of HT cable and one each after every 50-60 mtr distance/turning points complete all as specified and directed by Engg in chrg. |
| 50 | \\"DG SET\\" |
| 51 | Supply, installation, testing and commissioning of silent diesel engine driven generating set of capacity 5 kVA, 3-phase, 50 Hz, 415 volts, electric start, comprising diesel engine conforming to IS:10001 / IS:10002, coupled with brushless synchronous alternator conforming to IS:13364, complete with foundation as per OEM’s design, genset-mounted control panel with necessary meters and protections, and sound-proof acoustic canopy conforming to prevailing noise norms, including all accessories and connected works, complete all as specified and directed by engineer in charge. |
| 52 | “GRASS PAVER WORK” |
| 53 | Supply and fixing of precast grass concrete Paver Block any shape and size of 60 mm thickness set on compacted earth and joined with suitable earth including supply and plantation of grass selection I variety by dibbling root method complete including all the materials, labour, T&P, manure, fertilizers, other additives etc required for the activities for completion of said work and also shown in the note here-in-below:-Note:The following activities are to be carried out at site for planting of grass and the rate quoted against this item shall be deemed to include the cost of same, including necessary material, labour and T&P complete :(a) Anti-termite treatment : Providing and spraying BHC powder over soil over the area / lawn where grass to be provided(b) Dressing and levelling the soil to the required gradient and slope on completion of operation as mentioned in (a) above.(c) Well decayed Okhala manure in the proportion 3:1 (3 part soil : 1 part manure) shall be mixed with soil where grass to be planted. (d) Poring of water as required till completion of Phase-I work |
| 54 | \\"ARBORICULTURE WORK\\" |
| 55 | Supply only and stacking of good earth as approved by GE/Engr-In-Charge at site brought by the contractor outside of MOD land at his own arrangement including royalty and deposited on natural ground by trimming it properly and filling upto 30 cm depth. Earth measured in stacks will be reduced by 20% of volume including for payment. |
| 56 | Supply only, stacking and dumping manure of neem cake and cow dung of good qualities screened through sieve of IS designation 4.75mm as approved by GE Engr-In-Charge including carriage outside from MOD land (manure measured in stacks will be reduced by 8% for payment) |
| 57 | Mixing with earth, sludge or manure (neem cake and cow dung in ratio 1:10 by volume) in proportion. All as specified and directed by Engr-in Charge. |
| 58 | Digging holes in ordinary soil and filling the good earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after deduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :- (a) Holes 60cm dia and 60cm deep (200 Nos) (b) Holes 120cm dia and 1.20m deep (800 Nos) |
| 59 | Grassing with natural carpet grass selection No.1 grass including watering till the grass forms a thick lawn fit free from weeds and fit for mowing including supply of good earth and manure if needed (in rows 7.5 cm apart in either direction). Maintenance of the lawn incl watering, cleaning, weeding, fertilisation, watchup to avoid animal entry, cutting of lawns, hedge, creeper, ground cover, shrubs trees and remain responsible for replacement of dead plants, shrubs, grass and other casualties all as specified and directed by engr in charge. |
| 60 | Maintenance of Arboriculture for one year, including spreading of cow dung or chemical, removal of waste leafs and supply water and replace dry plants after completion of Phase-1. |
| 61 | Provision of plants at site, stacking and plantation with good earth mixing with manure including watering till the plants grown healthy permanent plants (pernial) as specified of following species. All plants/ shrubs must be approved before planting. Maintenance of the lawn incl watering, cleaning, weeding including supply of good earth and manure if needed, watchup to avoid animal entry, cutting of lawns, hedge, creeper, ground cover, shrubs trees and remain responsible for replacement of dead plants shrubs and other casualties all as specified and directed by engr in charge for one year since the completion of the work :- |
| 62 | Ficus pandas (4’-5’) |
| 63 | Ficus Benjamina 4-4.5 (1.20m to 1.35m) height well developed. |
| 64 | Ficus vaigetea |
| 65 | Bottle Palm (3’-4’) |
| 66 | Caliesteuman latus ansao (golden bottle brush) |
| 67 | Plumeria alba autifolia Please Enable Macros to View BoQ information |