| 1 | Complete removal of entire existing water proofing treatment in any position including tarfelt, plaster, lean concrete of any thickness, gravels etc. and removing the debries out side MD land complete all as specified and directed. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 3 | M&L for 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) thick rendering in CM 1:4 over concrete surfaces mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. Note: Water Proofing compound shall be measured and paid for seprately as \\"Supply Only\\" |
| 4 | Supply only WPC complete all as specified and as directed. |
| 5 | M&L Acrylic emulsion polymer of acrylic single component low viscosity polymer for preventing leakages over exisitng/New surface of slab, terrace, exterior, interior wall, Chajjas etc as per following procedure :-(a) Surface & surface preparation : Remove all the loose particles, dirt & dust clean by water, wire brush & mechanical cleaning, grease & oil should be cleaned using solvents, if the surface is previously coated with tar, it should be thoroughtly scraped off. The surface should be dry before application. All the cracks and crevices in the concrete slab to be filled with polyurethene based sealent with and including application of PU based primer complete all as specified and directed.(b) Finish paint : Apply water based polyurethenene modified dispersion (single component cold applied, non toxic, VOC compliant) in 03 coats icluding 01 coat of primer of same materials after dillution of water at 50 % or specific primer matching same material as per manufacturers specification complete all as specified and directed. |
| 6 | Dismantling tile work in floors ,hearth of wall tiles ,stone slab of any description and roofs laid in cement mortar including stacking material within 50 metres lead. (for thickness of tiles 10 mm to 25 mm) complete all as specified and directed. |
| 7 | M & L in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 8 | M & L first quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 9 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 10 | M&L for coloured glazed ceramic tiles of size 600mm x 300mm x 7 to 8mm thick of colour and pattern as approved by GE, as in vertical surface, including highlighter tiles as required set and jointed in neat cement slurry using grey cement and pointed in coloured cement to match the colour of tiles over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed. |
| 11 | M&L for Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick complete all as specified and directed. |
| 12 | M&L for Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete all as specified and directed. |
| 13 | M & L for granite 18mm thick black/red colour (of any type) work (table rubbed, and polished) in staircase steps, jambs, pillars, window-cills, cooking platforms, flooring and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl Screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes complete all as specified and as directed. |
| 14 | M&L for Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : With Modular bricks complete all as specified and directed. |
| 15 | S & F Machine cut cuddappa stone slab one side polished 20 to 25mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 20mm screed bed in cement mortar (1:6) complete all as specified and as directed.. |
| 16 | S & F Metal Frame Suspended Ceiling which includes perimeter channel of size 0.50mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with the Perimeter of ceiling, Screw fix to brick/ block wall / Partitions with the help of nylon sleeves then Suspending intermediate channel of size (0.80mm thick with two equal flanges each 15mm) from the soffit at 900mm Centres with ceiling angle (0.50mm x 10mm x 25mm) fixed to soffit with the help of soffit cleat and Rawl Plug then a Ceiling Section 0.50mm thick having web of 80mm and two flanges of 26mm each with leps of 10.5mm are then fixed to the intermediate channel and direction perpendicular to the intermediate channel at 457mm C/C. Single layer of 12mm thick Plaster board. (Strong Core and Strong Paper Bonding) is then screw to Ceiling Section with the help of 25mm Drywall Screw at 300mm interval complete all as specified and directed. |
| 17 | M & L 12 mm thick decorative Gyproc grey waterproof gypsum board fixed to timber frame work or metal frame with screws, as in suspended ceiling complete all as specified and directed. |
| 18 | M & L for providing and fixing 10 mm thick plaster of paris ceiling ( gypsum unhydrus ) to flat suface over second class soft wood fillets or metal frame and reinforced with GI wire mesh complete all as specified and directed. |
| 19 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 20 | S&F 12mm thick glossy/Matte Finish solid waterproof MDF board for wall panelling including necessary all fixing arrangement in timber framework exc 13 Sqcm but not exc 25 Sqcm in section as per requirement at site for fixing the items fitted in position to wall minimum screws size 120mm complete all as specified and directed. |
| 21 | S&F for Modular kitchen cabinet and wall mounted cabinet comprising of and including necessary all other fixing arrangement and screws as per requirement at site etc. All cabinet made of 18mm thick factory made moulding glossy/matte finish solid waterproof MDF board with all groove ,and outer side and top side shall be of 18mm thick prelam coloured solid MDF board, for fixing the items fitted in position and complete all as specified and directed. |
| 22 | S&F 12mm thick factory made moulding glossy/Matte Finish solid waterproof MDF board for kitchen wall cabinet back side and etc. comprising of with and including necessary all other fixing arrangement as per requirement at site. For fixing the items fitted in position to wall minimum screws size 120mm complete all as specified and directed. |
| 23 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc.of area 3 sq. metres and below complete and stacking within 50 metres lead complete all as specified and directed. |
| 24 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead area beyond 3 sq. metres complete all as specified and directed. |
| 25 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile B Fixing with adjustable lugs with split end tail to each jamb complete all as specified and directed. |
| 26 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in door frame filling and similar work filling complete all as specified and directed. |
| 27 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, complete all as specified and directedNote:- Butt hinges and necessary screws shall be paid separately) 12 mm thick plain grade -1, medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT- I, IS : 3087 marked, bonded with BWP type synthetic resin adhesive as per IS : 848 |
| 28 | M&L for 0.9 mm thick decorative laminate type 1,of surface finish, colour and pattern as approved, fixed with approved adhesives as per manufacturer's instructions complete all as specified and directed. |
| 29 | S& F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 30 | S&F aluminium anodised barrel tower bolts of extruded section 200 mm long. complete all as specified and directed. |
| 31 | S&F aluminium handles, anodised, cast type, of size 150 mm complete all as specified and directed. |
| 32 | S & F 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed. |
| 33 | S&F in repairs 25mm dia powder coated aluminium alloy curtain rails/draping rods of approved quality fixed to wall with suitable brackets & decorative end dome to rails complete all as specified and directed. |
| 34 | S&F three track sliding window with 4mm thick tinted glass in two shutter and one shutter using stainless steel wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing including good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified and directed and including taking down old steel windows. Series of aluminium section as per Jindal is (a) Bottom frame - 20620 (b) Top frame & vertical - 20621 (c) Handle (side) - 20606 (d) Shutter inter lock - 20724 (e) Shutter top & Bottom - 20844 (f) Glazing clips - 19352. |
| 35 | M& L for Silicon sealant for sealing of existing window aluminium frame with penetration depth 10 mm and 10 mm wide using sealant gun finished in triangular shape complete all as specified and as directed. |
| 36 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws with powder coated aluminium (minimum thickness of powder coating 50 micron) as per TD drawings complete all as specified and directed. |
| 37 | S&F For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 38 | M&L for Sheet tinted glass, selected quality, in squares exc 0.5 sq. m each pane 6.3mm Thick of approved colour in doors, partition fixed with and including rubber beading complete all as specified and directed. |
| 39 | Supply and fix in repair for aluminium powder coated partition using ‘Jindal’ aluminium SP/ DP section or equivalent make as specified with 5mm thick tinted/plain glass, PVC rubber beading fixed with glazing clips etc complete all as specified and as directed. Sections : SP (Single partition) - 20033, DP (Double partition) - 20034,Glazing clips - 4407 |
| 40 | S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 41 | Taking up or down steel tubing 15mm bore and connections including removal to store complete all as specified & directed. |
| 42 | All as per item herein above but 20 mm bore pipe complete all as specified and as directed. |
| 43 | S&F for steel water tubes, 20mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floor, complete including taking up or down steel tubing and connections complete all as specified and directed. |
| 44 | Providing and fixing 15mm bore concealled Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of jointscomplete all as specified and directed. |
| 45 | M&L for cutting chases, pinning in stone, concrete block walls making good to facings where required and pointing in cement mortar 1:3 to concealed water tubing and making good complete all as specified and directed. |
| 46 | S&F stainless steel kitchen sink with drainage board of overall size 915x460mm and bowl size 410x330x160mm with plugs,washers and wastes with including bedding in cement mortar to dwarf wall or including fixing cantilever brackets including removal of existing sink along complete all as specified and directed. |
| 47 | M&L for 100mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete complete all as specified and as directed. |
| 48 | S&F in repairs Bib taps fancy type long body chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as directed. |
| 49 | S&F PVC (SWR) junction, (Single Tee) equal or unequal 110 mm bore complete all as specified and directed. |
| 50 | S&F PVC (SWR) junction, (Single Tee) equal or unequal 75mm bore complete all as specified and directed. |
| 51 | S&F PVC (SWR) bends any radius 110 mm bore complete all as specified and directed. |
| 52 | S&F PVC (SWR) bends any radius 75 mm bore with trap door complete all as specified and directed. |
| 53 | S & F PVC (SWR) vent cowl 110mm Bore complete all as specified and directed. |
| 54 | S & F PVC (SWR) vent cowl 75mm Bore complete all as specified and directed. |
| 55 | S & F stainless steel grating dome 125mm dia complete all as specified and directed. |
| 56 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 57 | CEMENT PLASTER (IN COARSE SAND) 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) complete all as specified and directed. |
| 58 | CEMENT PLASTER (IN COARSE SAND) 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) complete all as specified and directed. |
| 59 | M&L for Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the old /new plastered wall surface to prepare the surface even and smooth complete all as specified and directed. |
| 60 | M & L for two coats of Oil Bound distemper with first quality Acrelic distemper (Ready Made) having VOC content less than 50gm/list of approved brand over one coat of primer on newly prepared surfaces to give even shade complete all as specified and as directed. |
| 61 | M&L for applying Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed. |
| 62 | E/M PORTION Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittingh etc removing etc removing materials for taking credit and making good distrubed surfaces of walls, floors and roofs etc complete all as specified and directed. |
| 63 | Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc complete all as specified and directed. |
| 64 | Taking down carefully unserviceable DBs any type/size with MCCBs/MCBs/Isolator etc and disconnecting and making good disturbed surface complete all as specified and directed. Please Enable Macros to View BoQ information |
| 65 | Taking down carefully unserviceable DBs any type/size with MCCBs/MCBs/Isolator etc and disconnecting and making good disturbed surface complete all as specified and directed. Please Enable Macros to View BoQ information |