|
| 1 | Part-A : Civil Work Based on BSR 2022, PWD Rajasthan |
| 2 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer-in-charge. |
| 3 | Demolishing mud phuska/ Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 50 meters lead. |
| 4 | Dismantling stone slab roofing over wooden karries and battens (dismantling karries and battens to be paid for separately) including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: |
| 5 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 6 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: |
| 7 | Brick masonry with F.P.S. bricks of class designation 75 in foundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) Add extra over item of brick work with class designation 100 in substitution of class designation 75 : Quantity in Cum. |
| 8 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 9 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 10 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 11 | Steel:-P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor five leve TMT bars (Conforming of relevent IS Code). |
| 12 | Providing and fixing M.S. sheet 1mm thick double leaf door shutter windows in angle iron frame 35x35x5 mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 13 | Glazed Window : Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13 x 3 mm , 10cm long embeded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement: 3 Course sand : 6 gradred stoneaggregate 20mm nominal size )or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4 mm thick with copper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer , excluding cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable ( fixed area not to exceed 33% ) |
| 14 | Wire Gauge Supplying & fixing fixed wire Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at not exceeding 150mm distance. 14 mesh X 24 Gauge |
| 15 | Guard Bars: Providing and fixing square bars or other flat welded to window/ventilators etc., Guard bar 12 x12mm |
| 16 | Polished Blue Kota Stone slab in steps, walls, pillars having fine machine cut edges laid on 12mm (Av.) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete : 20 mm thick slab area upto 900 Sq.Cm. |
| 17 | Polished Blue Kota Stone flooring skirting, laid over 20 mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing For area of each slab up to 2001 to 5000 Sq. Cm : 25 mm thick slab. |
| 18 | Internal Plaster : Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish: 12 mm thick |
| 19 | External Plaster : Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished 20 mm thick |
| 20 | P/L in position Cement concrete i/c curing,compaction etc of sp. Grade excluding the cost of C/S in superstructure with Cement concrete 1: 2: 4 (1 cement: 2 Course sand: 4 Greded stone aggregate 20 mm nominal size) |
| 21 | Providing & applying Three coat of Acrylic Water Proof membrane having sunlight and UV resistant properties over waterproofing slurry coat , initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 parts of clean water, over which applying 2 coats at 2 Hrs .intervals each with diluting 1 part of chemical with 20% of clean water for total thickness of 400 to 450 microns (covering area 0.9 Sq.M/Kg of chemical including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractor's labour, tools, machinery etc, complete as directed by Engineer in Charge. |
| 22 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 23 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia |
| 24 | Pipe Clip 110 mm dia |
| 25 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) |
| 26 | Interior finishing :- Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer. |
| 27 | Exterior finishing :- Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 28 | PART-C (Electric Work) Based on BSR 2022, PWD RAJ. |
| 29 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceiling rose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 30 | Short point (up to 3 mtr.) |
| 31 | Medium point (up to 6 mtr) |
| 32 | Long point (up to 10 mtr) |
| 33 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 34 | On board |
| 35 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 36 | 2 x 1.5 sq. mm |
| 37 | 2 x 2.5 sq. mm |
| 38 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR. |
| 39 | 4' LED Tube shape fixture 18/20 W (Polycarbonate Base) |
| 40 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Un-armoured 4.0 Sq. mm 2 core |
| 41 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 42 | 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 43 | Providing & Fixing of non modular socket size flush type 180 watt rotary minimum 5 step fan regulator as per PWD specification for electrical Works, ISI marked (IS:11037) made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 44 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |