| 1 | Material and labour for scraping the rusted surface of LT panel/feeder pillar any descreption/size (approx size 2 to 4 Sqm) and applying the primer coat of red oxide and painting on surface of LT Panels/feeder pillars 2 coats of super enamal paint grey/sky blue/existing colour with sparygun including writing of LT panel numbers in appropriate size of letters complete all as specified. |
| 2 | Supply and Fixing in replacement of Mild steel sliding door bolts plate type, stove enamelled black, with bright bolt not less than 12mm dia, 200mm long bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed on Front and rear side of the Doors of LT panel board complete all as specified. |
| 3 | Material and labour for repairing/replacing the broken hinges of LT panel shutters with stainless steel hinges of 200mm long by welding/bracing with nut bolts of existing LT panels shutters of any descreption complete all as specified. |
| 4 | M&L for replacement of LT panel / feeder pillar boxes front side or back side corroded / damaged double doors of size upto 1.50 m*1.50 m each by cutting, bending, welding MS sheet to suit with the existing MCCB's including providing hinges ,door locking system complete all as specified. |
| 5 | Supply, laying, testing & commissioing of 16 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing and taking down old U/S cable complete all as specified and as directedNote :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule. |
| 6 | All as per Ser No 5 above but size 10 sqmm 4 core |
| 7 | All as per Ser No 5 above but size 16 sqmm 4 core |
| 8 | All as per Ser No 5 above but size 25 sqmm 4 core |
| 9 | All as per Ser No 5 above but size 35 sqmm 3.5 core |
| 10 | All as per Ser No 5 above but size 50 sqmm 3.5 core |
| 11 | All as per Ser No 5 above but size 70 sqmm 3.5 core |
| 12 | All as per Ser No 5 above but size 95 sqmm 3.5 core |
| 13 | All as per Ser No 5 above but size 120 sqmm 3.5 core |
| 14 | All as per Ser No 5 above but size 185 sqmm 3.5 core |
| 15 | All as per Ser No 5 above but size 300 sqmm 3.5 core |
| 16 | Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified. |
| 17 | M&L for tibba sand locally available sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified. |
| 18 | M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50 mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified. |
| 19 | Laying only Old quarry faced stone slab retrived from respective items of sch complete all as specified. |
| 20 | Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified. |
| 21 | Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified. |
| 22 | Supply and fixing in replacement GI Pipe light grade 100 mm dia with necessary accessories/ fittings with pole/wall by iron clamps for cable protections/pole for crossing of culverts/nallah and all as specified and directed sizes:- |
| 23 | All as per ser item No 22 above but of size 80 mm dia |
| 24 | All as per ser item No 22 above but of size 50 mm dia |
| 25 | All as per ser item No 22 above but of size 40 mm dia |
| 26 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified. |
| 27 | Boring under road and foot path for inserting 40/50/80 mm bore GI tubing for drawing UG cable, complete all as specified. NOTE- GI Pipe to be paid in separate items complete all as specified. |
| 28 | Arranging fault locating machine to locate the fault in underground elect power cables of any length and any type of 1100 Volts grade LT cable and pin point the fault and testing of the cable after locating fault and cutting the cable at fault to check healthiness of cable before and after including excavation and earth work in any type of soil complete.Note :- Cable joints will be measured and paid separately under respective items of schedule. |
| 29 | Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core |
| 30 | All as per ser item No 29 above but of size 50-70 Sqmm x 3.5 core |
| 31 | All as per ser item No 29 above but of size 95-120 Sqmm x 3.5 core |
| 32 | All as per ser item No 29 above but of size 150-185 Sqmm x 3.5 core |
| 33 | All as per ser item No 29 above but of size 240-300 Sqmm x 3.5 core |
| 34 | Supply, fixing and testing end joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 10-35 Sqmm x 3.5 core |
| 35 | All as per ser item No 34 above but of size 50-70 Sqmm x 3.5 core |
| 36 | All as per ser item No 34 above but of size 95-120 Sqmm x 3.5 core |
| 37 | All as per ser item No 34 above but of size 150-185 Sqmm x 3.5 core |
| 38 | All as per ser item No 34 above but of size 300-500 Sqmm x 3.5 core |
| 39 | Material and labour for disconnecting power supply from LT ACB of cap. 630/800/1000 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and testing and putting on load complete all as specified. |
| 40 | Material and labour for disconnecting power supply from LT ACB of cap. 2500 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and testing and putting on load complete all as specified. |
| 41 | Material and labour for replacement of under voltage relay 230V 50 Hz AC supply suitable for 630A/800A/1000A capacity as required in existing ACB complete all as specified. |
| 42 | Material and labour for replacement of Shunt relay 230V 50 Hz AC supply suitable for 630A/800A ACB complete all as specified. |
| 43 | Material and labour for replacement of moving/fix contact suitable for 630A/1000A ACB complete all as specified. |
| 44 | Material and labour for replacement of charging Spring suitable for 630A/800A ACB complete all as specified. |
| 45 | Material and labour for replacement of Arc chute suitable for 630A/1000A ACB complete all as specified. |
| 46 | Material and labour for replacement of Limit Switch suitable for 630A/1000A ACB complete all as specified. |
| 47 | Material and labour for replacement of under voltage relay / Shunt relay 230V 50 Hz AC supply suitable for 1500/2500A capacity as required in existing ACB complete all as specified. |
| 48 | Material and labour for replacement of moving/fix contact suitable for 1500A/2500A ACB complete all as specified. |
| 49 | Material and labour for replacement of charging Spring suitable for 1500A/2500A ACB complete all as specified. |
| 50 | Material and labour for replacement of Arc chute suitable for 1500A/2500A ACB complete all as specified. |
| 51 | Material and labour for replacement of Limit Switch suitable for 1500A/2500A ACB complete all as specified. |
| 52 | S&F in replacement of MCCB,4 pole 63 Amp 16 KA , suitable for 415 volts, 50HZ 3 Phase, with adjustable Thermal & fixed magnetic,, over load and short circuit setting in existing LT panel/feeder pillar by requried modification in panel complete all as specified. |
| 53 | All as per ser item No 52 above but of capacity 100 Amps,4pole 415 volts 25 KA |
| 54 | All as per ser item No 52 above but of capacity 125 Amps,4pole 415 volts 25 KA |
| 55 | All as per ser item No 52 above but of capacity 160 Amps,4pole 415 volts 36KA |
| 56 | All as per ser item No 52 above but of capacity 200 Amps,4pole 415 volts 36KA |
| 57 | All as per ser item No 52 above but of capacity 250 Amps,4pole 415 volts 36KA |
| 58 | All as per ser item No 52 above but of capacity 315 Amps,4pole 415 volts 36KA |
| 59 | All as per ser item No 52 above but of capacity 400 Amps,4pole 415 volts 36KA |
| 60 | All as per ser item No 52 above but of capacity 630 Amps,4pole 415 volts 50KA |
| 61 | Material and labour for replacement of digital power factor Controller in existing APFC panels of suitable size having range of 1/5 A and 110v/230v/440v with all acessories complete all as specified.. Make : Epcos BR5100 or equivalent. |
| 62 | Suupply and Fixing in replacement of Digital Volt Meter 0-500 V including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 63 | Suupply and Fixing in replacement of Digital Amp Meter 0-250 Amp with CT three nos of same rating including making electric connection by suitable size of multistranded copper conductor with thimbles complete all as specified. |
| 64 | Taking out faulty underground LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of sizes up to 16 Sqm 4 core by excavation and relaying same laocation or any other location rectification of fault and removing of surplus soil.Note: Excavation, stone for cable cover, tibba Sand and earth work will be measured and paid for seperately under respective items of schedule. |
| 65 | All as per srl item 64 here in above but of size 25 Sqmm to 50 Sqmm |
| 66 | All as per srl item 64 here in above but of size 70 Sqmm to 120 Sqmm |
| 67 | All as per srl item 64 here in above but of size 150 Sqmm to 240 Sqmm Please Enable Macros to View BoQ information |
| 68 | All as per srl item 64 here in above but of size 150 Sqmm to 240 Sqmm Please Enable Macros to View BoQ information |