| 1 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 2 | Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35 x15 x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately.) |
| 3 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall |
| 4 | screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 5 | 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I, |
| 6 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under,including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In Charge. |
| 7 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metre lead. |
| 8 | For thickness of tiles above 25 mm and upto 40 mm |
| 9 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 10 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of |
| 11 | G.S. Sheet |
| 12 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 13 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 14 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 15 | Local best quality Teak wood |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 17 | Local best quality Teak wood |
| 18 | 35 mm thick shutters |
| 19 | Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, window and clerestory window shutters (Area of opening of glass panes excluding portion inside rebate shall be measured) |
| 20 | 5.5mm thick instead of 4mm thick |
| 21 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 23 | Water thinnable cement primer |
| 24 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: |
| 25 | One or more coats on old work |
| 26 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 27 | Old work (one or more coats) |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 29 | One or more coats on old work |
| 30 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, screws etc. to suit shutter thickness complete |
| 31 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required,embedding in floors and cover plates with brass pivot and single piece M.S. sheet embedding in floors and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge |
| 32 | With stainless steel cover plate |
| 33 | Providingand fixing ISImarkedoxidisedM.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 34 | 250x10 mm |
| 35 | ProvidingandfixingISImarkedoxidisedM.S.slidingdoorboltswith screws etc. complete |
| 36 | 300x16 mm |
| 37 | Providing and fixing ISI marked oxidised M.S.handle conforming to IS 4992 with necessary screws etc. complete |
| 38 | 125mm |
| 39 | Providing and fixing WPC Door |
| 40 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required. |
| 41 | grating, frames, guard bar, railing, brackets, gates and similar works |
| 42 | Providing and fixing cement fiber board 6mm thick |
| 43 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 44 | Local best quality Tolhao wood. |
| 45 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge |
| 46 | Local best quality Tolhao wood. |
| 47 | 35 mm thick shutters |
| 48 | Providing and fixing vinyl flooring including labour charge. Please Enable Macros to View BoQ information |