| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 2 | For thickness of tiles above 25 mm and upto 40 mm |
| 3 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in charge. |
| 4 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 5 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 6 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge |
| 7 | Unplasticed Polyvinyl - chloride (UPVC) pipe 110 mm outer dia. |
| 8 | 110 mm dia |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering --All work upto plinth level: |
| 10 | 1:4:8 ( 1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 11 | 1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 12 | Providing and laying autoclaved aerated cement blocks masonrywith 100mm thick AAC blocks in super structure above plinth levelupto floor V level in cement mortar 1:4 (1 cement : 4 coarse sand )The rate includes providing and placing in position 2 Nos. 6 mm diaM.S. bars at every third course of masonry work. |
| 13 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete. |
| 14 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand). |
| 15 | Acid and alkali resistant tile. |
| 16 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5sqm and under,including cutting the patch in proper shape, rakingout joints and preparing plastering the wall surface with whitecement based polymer modified self curing mortar, includingdisposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 17 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 18 | All kinds of soil. |
| 19 | Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and lift upto 1.5 m : |
| 20 | All kinds of soil |
| 21 | Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete. |
| 22 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 23 | Construction of granular sub-base by crusher run, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 |
| 24 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 25 | Thermo-Mechanically Treated bars |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 27 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 28 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 29 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 30 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : |
| 31 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 32 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : |
| 33 | 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 34 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 35 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 36 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 37 | Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 38 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : |
| 39 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 40 | 1:3 ( 1 cement : 3 fine sand) |
| 41 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 42 | Electric resistance or induction butt welded tubes. |
| 43 | Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)with zinc coating 120 grams per sqm as per IS: 277, in 240 mpasteel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto12 metre or as desired by Engineer-in charge. The sheet shall befixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with |
| 44 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 45 | Providing and fixing precoated galvanised steel sheet roofingaccessories , Zinc coating 120gsm as per IS: 277 in 240mpa steelgrade, 5-7 microns epoxy primer on both side of the sheet andpolyester top coat 15-18 microns using self drilling/ self tappingscrews or with polymer coated J or L hooks, bolts and nuts and orG.I. seam bolts and nuts, G.I. plain and bitumen washers complete : |
| 46 | Gutter (600 mm over all girth). |
| 47 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 48 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of Ist class teak wood and priming coat with approved steel primer all complete. |
| 49 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 50 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 51 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 52 | New work(two or more coats)over and including priming coat with cement primer:- |
| 53 | Applying priming coat: |
| 54 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works: |
| 55 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with screws etc. complete |
| 56 | 300x16 mm |
| 57 | Providingand fixing ISImarkedoxidisedM.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : |
| 58 | 250x10 mm |
| 59 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : |
| 60 | 125 mm |
| 61 | Laying Reinforced Cement Concrete PipeNP4/prestrssed concrete pipe on first class bedding in single row . (Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) |
| 62 | NP-4 Pipe |
| 63 | 1200 mm dia Please Enable Macros to View BoQ information |