| 1 | Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in hard / dense soil complete all as specified and directed. |
| 3 | Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m from straight point outside of MOD land complete all as specified and directed. |
| 5 | M & L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 6 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 7 | M&L Hard core of broken stone boulders of gauge n exc 63 mm, deposited spread and leveled in layers n exc 15 cm thick, watered and rammed to true surface complete all as specified and directed. |
| 8 | M & L for 100 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base, floors and pavings etc. including using plate type electric vibrator complete all as specified and directed. |
| 9 | M & L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) complete all as specified and directed. |
| 10 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in stirrups complete all as specified and directed. |
| 11 | M&L TMT bars 5mm and over upto and including 8mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified. |
| 12 | Formwork to sides of plinth beams, foundation and similar works vertical or to batter etc finising of surfaces rough complete all as specified and directed. |
| 13 | M& L reinforcement cement concrete, (nominal mix) type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in lintels over1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work, complete all as specified and directed. |
| 14 | Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board in ceiling fixed with screw as per manufacturers instructions size 595mm x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) at any height complete all as specified and as directed. |
| 15 | S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 grade St-240 complete all as specified and directed. |
| 16 | S & F Mild Steel plates (plain or chequred ) channels, square cut to notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. |
| 17 | M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 18 | S & F moulded pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 19 | S & F moulded pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in eaves sheeting /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 20 | S&F aluminium coloured powder coated window and ventilator shutters, fixed tyoe without sash bar, aluminium section weighing 0.55 kg/m including necesssary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc complete all as specified and directed. |
| 21 | S&F aluminium coloured powder coated door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 22 | M&L Anodised aluminium frame powder coating Minimum thickness 50 micron for doors windows,with one or more rebates including cleat for fixing etc complete all as specified and directed. |
| 23 | S&F of Aluminium composite panel (ACP) of 3/4mm thick sheet coated mirror glossy finish/ Natural wood finish of approved colour, pattern & design & as required shape like rectangular, trapezoidal or tapered curved shape (colour, shade, texture as per sample approved by GE and sample kept in GE office) with Poly Vinylidene Fluoride (PVDF) of flat panel that consist of two thin aluminium sheets (0.5mm thick) bonded to a non-aluminium core of flat sandwich panel is a structure of three layer aluminium core bonded between two sheets of required size fixed with heavy duty screws on aluminium chanel rectangular section of size 38mm X 25mm thickness 2mm for vertical & horizontal frame work or equivalant section with respect to weight, and used for external cladding or facades, partition, false ceiling, signage, etc. The joints to be filled with silicon seelant of translucent, white or black in colour with the help of portable punch machine work pneumatically after cutting the carners and edges. A protective film on ACP is removed after installation complete all as specified and directed. |
| 24 | S & F aluminium deco grills conforming to DG-104 grade complete all as specified and directed. |
| 25 | S&F 5.5 mm thick plain or tinted glass, ordinary quality including rubber gasket for packing and fixed to aluminium doors/window/partition incl necessary cutting / moulding and chamferring of edges for service window/counters complete all as specified and directed. |
| 26 | S&F brass body mortice lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specified and directed. |
| 27 | S& F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 28 | M&L brick work in CM 1:6 with using old size sub class `B ` brick straight or curved on plan exceeding 6.0mtr mean radius complete all as specified and directed. |
| 29 | M&L for 15 mm thick cement plaster in cement mortar 1:6 surfaces on fair face of brick work and finished even and smooth w/o using extra cement complete all as specified. |
| 30 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as directed and specified. |
| 31 | Material & labour for preparation of new plastered surfaces and applying two coat of exterior grade modified antifungal water based weather proof acrylic emulsion dirt cleaning property paints on wall, fins, facias, chajjas over a coat of primer incl 1mm thick wall care putty etc upto and including 4th storyed high building complete all as specified and as directed. |
| 32 | M&L for preparation of new plastered surfaces of walls, and applying two coats of two coat of 1st quality oil emulsion distemper over a coat of primer incl 1mm thick wall care putty on walls complete all as specified and directed. |
| 33 | M & L 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate),as in plinth protections/hastanding complete all as specified and directed. |
| 34 | M&L for kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match th shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 35 | All as per item no 34 above but as in skirting/dado complete all as specified and directed. |
| 36 | S&F non skid coloured ceramic tiles area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm and 7mm thick as in floor set & jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:4 complete all as specified and as directed. |
| 37 | S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved and 100mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping complete all as specified and directed. |
| 38 | M&L Sand filling under floors or in foundation including watering and consolidtion complete all as specified and directed. |
| 39 | M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate) as in grouting of angle posts, pillars ,coping, plinth courses,parapets and raillings etc including necessary form work complete all as specified and directed. Please Enable Macros to View BoQ information |
| 40 | M&L for PCC 1:2:4 type B-1, (using 20mm graded stone aggregate) as in grouting of angle posts, pillars ,coping, plinth courses,parapets and raillings etc including necessary form work complete all as specified and directed. Please Enable Macros to View BoQ information |