| 1 | Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent Addressable Muliticriteria Type Detector having twin LED’s for 360 degree viewing angle & hard Addressable having rotary decade addresss which is from 01-99. LED on the detector shall blink each time the sensor is scanned by the FACP. If the FACP determines the sensor is in alarm, the FACP will command the sensor LED to remain on to indicate the same. Each Sensor will be capable of being tested for alarm via command from the FACP. Each sensor shall respond to FACPs can with the Information about its type for identification all as specified and directed. |
| 2 | Supply,Installation,Testing & Commissioning of UL/EN Listed Fault Isolator Module. This unit shall be placed on the loop preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring. All the other detectors shall remain functional because of the Class A wiring of the loop. The isolator shall not utilize an address and shall be built into the detector base wherever required all as specified and directed. |
| 3 | Supply,Installation,Testing&Commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting glass break type having Rotary Decade Switces for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standard sand Duly Approved by EN54 /LPCB /VDS /UL/ BSA complete all as specified and directed. |
| 4 | Supply,Installation,Testing & Commissioning of Response Indicator for above false ceiling detectors & detectors installed inside cabins.Response indicators with all accessories shall be as per technical specification complete all as specified and directed. |
| 5 | Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent addressable Output module having facility to activate AHU,Lifts etc.having option of RAIL or Surface MountingwithTri Color LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 complete as required as per specification complete all as specified and as directed. |
| 6 | Supply,Installation,Testing & Commissioning of UL/EN Listed Intelligent addressable Input module for monitoring purpose having option of RAIL or Surface Mounting withTri Color LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 dully approved to GEAGE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed. |
| 7 | Supply,Installation,Testing & Commissioning of the Alarm Repeater /Annunciator Panel shall display fire /fault messages simultaneously with the FACP. It shall be capable of interfacing with the FACP on a single RS485Bus.The panel shall be capable of operating on 24V DC supply. The panel shall have a 2x40 character back light alphanumeric LCD display, which shall display date, time & description of alarm / trouble events that are displayed in the FACP with an inbuilt buzzer to indicate fault/fire alarm.It shall have control keys for Sound, Silence,Mute and to reset the FACP from the repeater station complete all as specified and as directed. |
| 8 | Supply,Installation,Testing & Commissioning of UL/EN Listed loop powered Sounder CUM Strobe complete as required as per specification Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed. NOTE: NO additional power supply and control module shall be required to trigger the sounders. |
| 9 | Supply,Installation,Testing & Commissioning of UL/EN Listed Analog addressable Fire Alarm system,having the capacity of 99 devices & 99 detectors per loop.The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 999 events. Further,the panel must be able to automatically switch ON/OFF respective control module whenever any alarm is triggered.The panel should have in built common Alarm,Fault and monitored sounder output. The panel shall have a alphanumeric LCD display and having minimum160 Characters in the display. A minimum of two on-board sounder circuits shall be provided.The sounder out puts shall be fully programmable, monitored and short-circuit protected.The panel shall have a built in power supply and battery charger, 24V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm condition and complete as required as per specification.The fire alarm panel should be network able upto 99panel & repeater panel. A walk test option shall be provided for convenient testing of detectors and alarm initiating devices without continually having to reset the panel.The fire alarm panel shall be compatible for hardware / software integration of PA System.The panel shall provide a flexible way of performing complex cause-and-effect programming.The fire alarm control panel shall have the ability to automatically invoke different operating modes according to the time of day.The control panel shall be capable of expansion. Capacity of upto five analogue addressable detection loops,using five plug-in loop driver modules shall be available.The control panel shall support upto five analogue addressable loops with the capability to control 495 analogue sensors and 495 addressable modules giving the maximum capacity of 990 addresses in case of five loop panel. Each mode shall have adjustable startand finish times. 20number zonal fire indicators(LED’s) and 20 number zonal fault/test/disabled(LED’s) shall be provided.The fire alarm control panel shall have three user control levels. A dedicated RS232 port shall be available for both connections to a local printer and upload /download of configuration data via the manufacturer’s standard PC programming tool.The FACP shall have the provision to integrate with two way fire fighter control system.The FACP shall be able to supervise individual detectors for proper performance as well as to give pin point location of Fire or Fault alarm and initiate alarms as well as facility for cutting off of AHU’s and Electrical Power is also tobe included.The panel shall be compatible with IBMS system with MODBUS protocol. EN54/UL/LPCB approved complete all as specified and directed. |
| 10 | Supply and installation of Loop driver card complete all as specified and directed. |
| 11 | Supply and installation of RS 485 Communication module complete all as specified and directed. |
| 12 | Supply and installation of Modbus TCP/IP interface module. Requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed. |
| 13 | Supplying, drawing, connecting, testing & commissioning of 2 core, 1.5 sq. mm. stranded copper conductor, PVC insulated PVC sheathed,aluminium myler tape shielded FRLS wire in draw through existing conduit complete all as specified and directed. |
| 14 | Supply and laying of 25 mm Dia rigid steel conduit fixing on wall/roof/ceiling etc including concealed in wall and securing with proper saddle and making good disturbed surface and well finishing (For Fire Detection) all accessories complete all as specified and directed. |
| 15 | S&F false ceiling with Semi perforated 12mm thick acoustical false ceiling, (fire retardant and sound absorbent) micro regular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595mmx595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 475 (Part 4) -1970 and light code description unit rate No 429 Sub Head : 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint -T runners of size 15mmx32mm of length 300mm, cross -T of size 15mmx32mm of length 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @80 grams per sqmm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85mmx25mmx2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall /partition with the help of plastic rawl plugs at 450mm centre to canter and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction |
| 16 | S&F for solid PVC wall panelling decorative type consisting of 5 mm th plain colour PVC pre-laminated sheet inclusive of solvent cement and and fixing at site on PVC frame/wooden frame as per specification and drawing, complete all as specified and directed. |
| 17 | S&F for 5 mm thick PVC sheet fillets of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing, complete all as specified and directed. |
| 18 | S&F in position wall panelling at all heights (fire retardant and sound absorbent) with GRG ( Glass Fibre Reinforced Gypsum) panels/tiles of 10 mm thick fully perforated suitable for acoustic purpose of size 595mm x 595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRC 0.70 to 0.85 as per IS 8225:1987, Non combustible as per BS 476 (Part 4)-1970 and light Reflectance of 75% to 85% (Minimum), comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanising @ 120 grams per square metre including both sides) i.e vertical studs of size 48mm x 34mm x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel section of nickel coated size 50mm x 32 mm fixed to the floor and ceiling at 600 centres using 12 mm dia, 50 mm long wedge type expanded zinc alloy dash fasteners with 10 mm bolt. The same channel is then to be fixed in horizontal direction at 600 centre to centre so as to form a grid of 600 x 600 mm. Glass wool of 50 mm thickness is then to be inserted in the slots and finally GRG ( Glass Reinforced Gypsum) non combustible panels/tiles are to be screw fixed with self tapping pan head nickle coated mild steel screws of size 13 x 3.2 mm on this grid leaving an even groove of 1 mm between the panels. The joint between the panels are to be duly jointed and finished using recommended jointing compound and fibre joint tape roll 50 mmm wide (90 meter) roll and two coats of primer suitable for panelling as per manufacturer's specifications as per direction. |
| 19 | M&L for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38mm x 24 mm , cross Tee 29mm x 24 mm and wall angle 24mm x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted cement fiber board size 595mm x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per at any height complete all as specified and directed. |
| 20 | M&L for rendering 10mm thick plaster on internal surfaces of brick work/stone work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement and also including taking down of old/existing rendering surfaces complete all as specified and as directed. |
| 21 | M&L for preparation of new surfaces of walls, and applying two coats of distemper oil emulsion over a coat of alkali resistant primer over and incl 1 mm thick wall care putty on wall surface complete all as specified and directed. |
| 22 | M&L for preparation of old surfaces of walls, and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. Please Enable Macros to View BoQ information |