| 1 | Building & Sainatary Work Based on BSR PWD - 2022, Jaipur Circle, Electric Work Based on BSR PWD 2022, Jaipur Circle, Part -A Civil Work |
| 2 | Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 3 | Lintel Beam : Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 4 | slab & beam:providing and laying in position spwcified grade of cement concrete for RCC structural elements up to floor five level including curing,compaction,finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints and cost of plastizers ( if required) excluding the cost of centering shuttering and reneforcement for brams suppended flore roofs griders having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, starecase and spiral starecase etc. M20 grade Nominal mix / Design mix |
| 5 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 6 | P/F reinforcement for RCC work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete upto floor five leveTMT bars (Conforming of relevent IS Code). |
| 7 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 8 | Providing and fixing M.S. sheet 1mm thick double leaf door shutter windows in angle iron frame 35x35x5 mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 9 | Glazed Window : Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13 x 3 mm , 10cm long embeded in cement concrete block 15 x 10 x 10 cm of 1:3:6 (1 cement: 3 Course sand : 6 gradred stoneaggregate 20mm nominal size )or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4 mm thick with copper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer , excluding cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable ( fixed area not to exceed 33% ) |
| 10 | Wire Gauge Supplying & fixing fixed wire Gauge to the Metal frame of rolled section by metal beading 20X3mm with suitable screw at not exceeding 150mm distance. 14 mesh X 24 Gauge |
| 11 | Guard Bars: Providing and fixing square bars or other flat welded to window/ventilators etc., Guard bar 12 x12mm |
| 12 | kota stone slab flooring 25 mm thick over 20mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 Course sand ) for area 2001 to 5000 sq. Cm |
| 13 | kota stone slabs 25 mm thick in risers and steps skirting, dado and pillars laid on 12 mm (average)thick cement mortar 1:3 (1 cement: 3 Course sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs , including rubbing and polishing complete For area of each slab upto 2001 sq. Cm |
| 14 | Internal Plaster : Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish: 12mm thick |
| 15 | External Plaster : Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished 20 mm thick |
| 16 | Plaster(Ceiling): 6 mm thick cement plaster to ceiling of mix 1:3 (1 cement: 3 fine sand) |
| 17 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. South Zed Black (Above 3601 Cm2 Slabs) |
| 18 | Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 19 | Gola Providing gola 75mm x 75mm in cement concrete 1:2:4(1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge) including finished with cement mortar 1:3(1 cement: 2 fine sand) as per standard design. |
| 20 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 21 | Internal Finishing: Wall painting with plastic emulsion paint of approved brandand manufacture to give an even shade including allscaffolding:Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. |
| 22 | Internal Finishing: Wall painting with plastic emulsion paint of approved brandand manufacture to give an even shade including allscaffolding: Old work (One or more coats ) |
| 23 | Exterior finishing :- Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision New Work |
| 24 | Exterior finishing :- Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision Old Work |
| 25 | PANTING ON DOORS & WINDOWS :- Painting with syntheitic enamel paint of approved brand and manufacture in all shade to give an even shade new steel work (2 or more coat on new work). |
| 26 | Copping: Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls(any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, copping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M20 grade nominal Mix 1:1.5:3(1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 27 | Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as perdirection of Engineer-in-charge. 1: 3: 6 or richer mix |
| 28 | Dismantling old plaster or skirting, raking out joints andcleaning the surface for plaster including disposal of rubbishto the dumping ground within 50 meter lead. |
| 29 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 30 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia |
| 31 | Pipe Clip 110 mm dia |
| 32 | Providing and fixing in CM 1:4 double paitam (rebated) stone door window and ventilator frames of approved quarry. Size 100X75 mm |
| 33 | PART-B (sanitary Work) |
| 34 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40 mm C.P. waste coupling C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor.(WVC Lab sink (I.S 2556 mark) size 530 X430X180 mm) |
| 35 | P & F chromium plated Swan-neck Laboratory Cock of approved quality/make: One Way. |
| 36 | P & F Bib Cock (IS : 8931 Mark) superior quality of approved make.C.P. Brass 400 gm, 15 mm nominal bore. |
| 37 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.Brass wt. 400 gm, 15 mm |
| 38 | P & F Inlet connection (Angle Valves) Superior quality of approved make C.P. Intel connection 15 mm brass (IS : 8931) |
| 39 | P & F 15 mm dia connection pipe of approved quality make PVC Pipes with nuts 450 mm. |
| 40 | P & F Full way valve (IS : 778 Mark) or wheel valve of approved make. Gun metal 15 mm nominal bore. |
| 41 | P & F Stop cock (IS:8931 Mark),Superior quality and of approved mark: Brass 400 gm. 15 mm nominal bore |
| 42 | P & F PVC Storage Tank ISI Marked ( IS : 12701) indicating the BIS license No. of approved make with cover , 25mm dia 1 M long G.I. overflow pipe & 25 cm long wash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity |
| 43 | Supply & Fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size.15 mm dia nominal bore |
| 44 | P&F GI Pipes (External Work) with GI fittings excluding union (SI: 1239 Mark) including trenching and refilling each etc. 15 mm dia nominal bore B Class |
| 45 | Providing & Fixing Ist quality standard White, gray, ivory,fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 and IS: 15622 of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls and piller) |
| 46 | PART -C, (Electric Work) |
| 47 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . , Short point (up to 3 mtr.) |
| 48 | Medium point (up to 6 mtr) |
| 49 | Long point (up to 10 mtr) |
| 50 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . on board |
| 51 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . MMS (9537 P-111)PVC condute.25mm. |
| 52 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 2 x1.5 sqmm |
| 53 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 2 x2.5 sqmm |
| 54 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .6A TO 32A rating. |
| 55 | Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .IP-43 DOUBLE DOOR (SINGLE PHASE).8WAY (8O/G+2I/C) |
| 56 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 57 | Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing |
| 58 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:- (a) Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I / IS :7098 P - I (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . (c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Un-armoured 6 sqmm 4 core |
| 59 | Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 1200mm sweep 3 star |
| 60 | Providing & Fixing of ISI marked (IS:1258) 6 amp batten/angle lamp holder as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 61 | P & F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 62 | Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. , label holding facility , IP 20 contact protection and fitted with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 30/40 amp rating . |
| 63 | Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .5 step fan regulator 100 watt 1 Module. 5 step fan regulator 100 watt 1 Module |
| 64 | Providing & Fixing of ISI marked (IS :3854) 6 amp. flush type non modular switch as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, minimum width of switch toggle ( PUSH PART ) should not less then 18 mm, brass terminal & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 65 | Providing & Fixing of of 3 pin 6 amp. flush type non modular socket as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |