| 1 | Building & Sainatary Work Based on BSR PWD - 2022, Jaipur Circle, Electric Work Based on BSR PWD 2022, Jaipur Circle, Part -A Civil Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 3 | P.C.C. IN FOUNDATION :- Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 gradeed stone aggregate 40 mm nominal size). |
| 4 | R/R stone masonary for foundation and plinth in cement sand mortar above 30 CM thick wall in : cement mortar 1:6 (1 cement : 6 sand) |
| 5 | Random Rubble stone masonry with hard stone in superstructureabove plinth level anduptofive level above 30cm. thick walls in |
| 6 | Copping -Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 7 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required excluding the cost of centering, shuttering and reinforcement . M20 Grade Nominal Mix. |
| 8 | Kharanja - Random Rubble dry stone kharaja under floor |
| 9 | PCC: Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:3:6(1 cement:3 Coarse sand :6 graded stone aggregate 20 mm nominal size).M 10 grade nominal mix |
| 10 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required Partly fixed and partly openable [ fixed area not to exceed 33%] |
| 11 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 12 | Guard Bar - Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 12mmx12mm |
| 13 | Internal Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick Sqm |
| 14 | External Plaster :- Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick Sqm |
| 15 | 6 mm thick cement plaster to celling of mix 1:3 ( 1Cement :3Fine sand) |
| 16 | Providing and fixing M.S. sheet 1mm thick double leaf door shutter windows in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint |
| 17 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 18 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant. 110mm dia |
| 19 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 20 | Nano technology water proofing, thermal insulation protection coating : Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. 15.28.2 Nano technology water proofing, thermal insulation protection coating 9 layer process for increasing life of building and damage control protection for walls.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in 2 coats non silicon based thermal insulation coating highly elasticity in nature with 2 coats with 1000 micron thickness 2 top coats of anti slippery, natural transparent high shine chemical for better life of the treatment. Nano technology water proofing or anti stain protection coating 5-7 layer process for increasing life of all stone fascia/facades/flooring or stone building and damage control protection, life 7-9 years, warranty 5 years-- before coating washing of stone and degreasing of that area is done 1 coat. (Removing of algae/moss/blackness/stains/rust etc. is extra) then after drying doing 1 coat of Nono technology hydrophobic prime. After this on dry area Nano technology water proofing treatment in 3 coats wet on wet. In case of anti stain treatment 2 top coats of anti stain, anti slippery, natural transparent high shine or matt chemical treatment is done. BSR_B15 S |
| 21 | Chequred precast cement concrete tiles 22 mm thick in footpath &courtyard jointed with meat cement slurry mixed with pigment to match the shade of shade of tiles including rubbing and cleaning etc.complete on 20mm thick bed of cement mortar 1:4 ( 1cement : 4 coarse sand ) Light shade using shade cement. |
| 22 | 120cm. high fencing with angle iron posts 50x50x6mm. placedat every 3 Mtr. apart 30cm. in ground embedded in cementconcrete 1:3:6 (30x30x45cm) corner & every tenth posts to bestrutted with 50x50x6mm angle iron provided with fourhorizontal lines and two diagonals of black barbed wirebetween two posts fitted and fixed with G.I. staple includingearth work in excavation etc. complete Extra for using galvanized barbed wire instead of black barbed wire.Add Extra if barbed wire fencing is done on wall upto height of 3.00 Mtr. |
| 23 | Internal Finishing: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 24 | Internal Finishing: Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats ) |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 26 | Exterior finishing :- Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision Old Work |
| 27 | Painting with enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. |
| 28 | Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. |
| 29 | Part -B, Electrical Work. |
| 30 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . , Short point (up to 3 mtr.) |
| 31 | Medium point (up to 6 mtr) |
| 32 | Long point (up to 10 mtr) |
| 33 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSROn board |
| 34 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR25mm |
| 35 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm |
| 36 | 2 x 2.5 Sqm |
| 37 | P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 38 | P & F ISI marked (IS:3854)3/6pin 16 amp. flush type non modular socket with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |