| 1 | Panel |
| 2 | 90.14.1.1Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame) |
| 3 | 90.14.3.1Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 4 | 90.14.5Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 5 | 90.14.6Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. asrequired. |
| 6 | 90.14.7 Supply and providing copper earth bus in the panel board |
| 7 | 90.14.2.2Supply and providing 3mm SMC sheet as shrouding for bus interconnection /terminations etc. including required nut & bolt etc. |
| 8 | OD222078/2025-2026Providing and fixing following capacity open execution tye FN (TPN) dis connector fuse switch unit inside the existing panel board with 315A ISI marked DIN fuse links including drilling holes in cubicle panel, making connections, etc. as required. 400 Amp TP & N SDF |
| 9 | OD222178/2025-2026Providing and fixing following capacity TP&N inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required.125A TPN Isolator |
| 10 | OD222179/2025-2026Providing and fixing following capacity TP&N inside the existing panel board including drilling holes in cubicle panel, making connections, etc. as required. 400A TPN Isolator |
| 11 | OD222177/2025-2026Supply and fixing LED indicator Red, Green, Black, Yellow, Orange colors 22.5 mm cut out |
| 12 | OD222176/2025-2026Supply and fixing LED indicator Blue color 22.5 mm cut out |
| 13 | OD222838/2025-2026supply and fixing 20A fuse holder with 2A link using suitable nut bolt etc. asrequired. |
| 14 | 90.6.4.1Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 15 | OD309766/2025-2026 Labour charge for dismantling the existing 3.5X 185 and 4X25 sq.mm Aluminium UG cable from the panel and change over, remove the gland, earth connections etc.from the panel, re terminating cable in the newly proposed panel and giving connections etc.as required. |
| 16 | 9.1.27Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm) |
| 17 | 9.1.34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 18 | 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG) |
| 19 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 20 | 90.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG) |
| 21 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 22 | 90.6.10.1Supply and fixing of following sizes of light gauge PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 23 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 24 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm |
| 25 | OD222175/2025-2026Preparation of necessary forms,documents,drawings etc.for approval and energisation certificate from the Electrical Inspectorate. |
| 26 | OD222174/2025-2026Providing additional sheets of drawing layout as required |
| 27 | Fire Panel Automation |
| 28 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 29 | 90.6.4.1Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 30 | 90.6.5.3Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.00 sq mm |
| 31 | 90.6.5.4Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm |
| 32 | OD256906/2025-2026Labour charge of control wiring for automation of AMF panel and fire pump panel |
| 33 | 90.6.5.5Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 2.50 sq mm |
| 34 | OD298405/2025-2026Supply and providing On delay timer 240VAC/24VAC/DC and giving connection. |
| 35 | 90.12.24.1Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm |
| 36 | OD296894/2025-2026Supply and fixing 100A fuse holder suitable for providing cylindrical HRC fuse link including providing 80A HRC fuse link |
| 37 | OD309760/2025-2026Supplying and fixing 2A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 38 | OD300685/2025-2026Supply and providing controll relay contactor and MXo22E/equivalent and givingconnection. |
| 39 | OD309811/2025-2026Labour charge for commissioning the whole system with proper testing usingrequired items Please Enable Macros to View BoQ information |