| 1 | Electrification |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | 1.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A |
| 5 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 6 | OD198627/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of 1200 mm commercial LED integrated batten made of extruded Aluminum body and polycarbonate diffuser complete with all accessories etc. 1x 18 w LED fitting with electronic driver, Aluminum heat sink, 6500 K ,50000 Burning Hrs, flicker free , efficiency 2100 lumen efficiency suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, etc fittings directly fixed on wall or ceiling with factory made steel clamp to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. .. Philips make model no. Smart Bright essential BN170 C LED20S-6500 L120 PSU or it's equivalent. |
| 7 | OD346855/2025-2026:Supply conveyance installation testing and commissioning of 2 way wall washer light fittings ,5 W LED E 27 lamp base model no - 800042 , PhilipsLucent 2 way 5W IP 65, aluminium material , anthracite grey colour , dimensions L8xW 6.5xH4.2 cm with LED bulb and required accessories etc as required. |
| 8 | OD346856/2025-2026:Supply conveyance installation testing and commissioning of LED E 27 lamp base type Double head Fancy wall light fittings model - 31426, Philips muziris wall light 2 head , metal, diamension 150x272x227 , rate with 7 W 2 nos LED bulb ,with required accessories etc as required. |
| 9 | OD346857/2025-2026:supply conveyance installation testing and commissioning of 7W LED E 27 type Fancy wall light fittings model - JNL-NKL-WCRB0480SE27E27 with required accessories etc as required (Jaguar makes). |
| 10 | OD198597/2025-2026:Supply and fixing Conveyance, installation, testing and commissioning of 1000 lumen round/ square surface fitting made of Aluminium pressure die cast , having efficacy not less than 110l/w, PHILIPS make:SM295C LED10S-3000 PSU WHSM295C LED10S-3000 PSU WH or equavalent directly on ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required |
| 11 | OD346858/2025-2026:Supply conveyance, installation, testing and commissioning of 1200 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, 4000 to 6000K, pf greater than 0.95, THD less than or equal to 10%, (Chip make Cree/Osram/lumilled/Nichea) and giving connections with 16/0.20 mm 3 core PVC insulatedand sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. Make: Philips/Osram/Havells or its equivalent. |
| 12 | OD346887/2025-2026:Supply conveyance, installation, testing and commissioning of 1800 lumen round/ square(1X1)surface mount fitting made of diecast aluminium, having efficacy not less than 110l/w, 4000 to6000K, pf greater than 0.95, THD less than or equal to 10%, (Chip makeCree/Osram/lumilled/Nichea) and giving connections with 16/0.20 mm 3 core PVC insulatedand sheathed round copper conductor flex wire or extending the original wiring and givingconnections as required. Make: Philips/Osram/Havells or its equivalent. |
| 13 | OD346849/2025-2026:S u p p l y , c o n v e y a n c e , installation, testing and commissioning of 10W LED mirror lamp complete with all accessories and lamps etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(K Lite 1597 or equivalent make ) |
| 14 | OD346942/2025-2026:Supply conveyance installation testing and commissioning of Electronic foot lamp philips make with required accessories etc as required. |
| 15 | OD346851/2025-2026:Supply Conveyance, installation, testing and commissioning of 6W LED bulk headfittings suitable for surface and wall mounting output greater than 115 lumen/W 6500K with IP 66 protection and IK09 protection with power factor greater than 0.95 atfull load, internal surge protection up to 4 KV,and corrosion proof LM6 gradepressure die cast aluminum body & poly carbonate diffuser cover complete withTHD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired upfor use on 230 V AC supply. including fixing as required Philips endura or itsequivalent |
| 16 | OD346922/2025-2026:Supply and installation , Conveyance, installation, testing and commissioning of LED Indoor Wall 7W Picture with E 27 Warm white 4000 K bulb and fittings directly fixed on wall and giving connections as required Philips make Picture light model No31402 or its equivalent etc. as required. |
| 17 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 18 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 19 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 20 | OD347218/2025-2026:Supply, conveyance, installation, testing and commissioning of Decorative Underlight Ceiling Fan ( gold body and Ivory leaf) sweep Size 1235 mm;Speed 320 RPM MOTOR; Air Delivery 220 CMM;Input Power 80 W POWER using standard accessories, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm sweep, Dust proof coating, Auminium blade, double ball bearing with remote control, BLDC 5 star rated ceiling fan complete with300mm down rod , canopies, shackeles and blades working on 140V/285V single phase AC Crompton Uranus its equivalent make etc as required. |
| 21 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 23 | OD350757/2025-2026:Supply and installation , Conveyance, installation, testing and commissioning of LED Wall Lights,4000 K warm for outdoor purpose and all accessories and fitted directly on wall and giving connections as required Philips Robin 6W Black LED Wall Lights or its equivalent etc as required. |
| 24 | 1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 25 | 90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 26 | 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 27 | OD346984/2025-2026:Supply Conveyance, installation , testing and commissioning of exhaust fans (in and out type) of size 225 mm sweep 1350/1400 RPM Exhaust fan in metal frame with metal guard , bird guard including anti corrosive powder coated , working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan as required (almonard or its equivalent) |
| 28 | 1.19:Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 29 | OD347192/2025-2026:Supplying and fixing suitable size metal box in recess with Wired Call Bell with Light & Sound Alert minimum 12 room indication , with switch suitable size with ABS or phenolic laminated sheet cover in front and giving connection as required etc as required. |
| 30 | OD347232/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. modular type 2 module 16A Key tag |
| 31 | 1.24.7:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 32 | OD347305/2025-2026:Supply and fixing of weather proof (IP 66) thermoplastic box having minimum (size180x130x77)for terminating cable and Switch/MCB/Isolotor etc with using suitable din channel etc.as required. Hensel or equivalent make |
| 33 | OD350070/2025-2026:Supply and fixing12 A, 3 pole power Contactors AC 3 rating at 415 V, with AC Coil, and giving connection as required |
| 34 | OD350087/2025-2026:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. USB charger 1500mA Type C-1 Module, etc as required. |
| 35 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 36 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 37 | OD350107/2025-2026:Supply and fixing 20mm corrugated flexible pvc conduit. |
| 38 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 39 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 40 | 1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 41 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 42 | 1.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm |
| 43 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 44 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 45 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 46 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 47 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 48 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 49 | 1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 50 | 1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 51 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 52 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 53 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 54 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 55 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 56 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 57 | 1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 58 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 59 | 90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) |
| 60 | 90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 61 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 62 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 63 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 64 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 65 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 66 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 67 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 68 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 69 | 90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 70 | OD350197/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, color washing etc. including giving necessary connections as required. (excluding cost of HRC fuse links in case of SDF/ SDFCO) ( front handle) 63 A, 4 pole On load changer switch in sheet steel enclosure |
| 71 | 90.12.1.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm |
| 72 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 73 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 74 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 75 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 76 | 9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 77 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 78 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 79 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 80 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 81 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 82 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 83 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 84 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 85 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 86 | OD350417/2025-2026:Supply and providing 25x3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. |
| 87 | OD350434/2025-2026:Supply and providing iron hook for binding service wire |
| 88 | OD350437/2025-2026:Supply and Installation of dust and vermin proof , wall mounting , sintex meter box of size 650x350x250mm suitable for fixing KSEB meter ,fuse units etc, hinged door connection for the front side with compartments if necessary , providing vision panel for the meter component , knock out for cable entry and exit.etc as required. |
| 89 | OD350435/2025-2026:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connections etc. |
| 90 | OD350436/2025-2026:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc |
| 91 | OD351406/2025-2026:Supply and providing Danger 415 V, 125 x 75 mm aluminum anodized legend plates in the existing panel board as required |
| 92 | OD350446/2025-2026:Supply, Conveyance,Testing and Commissioning of vertical wall mounting type 5 star rated 6 litres Instant Water Heater, 3 KW ,copper container with puff insulation and PVC body working on 230 Volt 50 Hz A/C supply , fixing on wall using suitable size anchor bolt / Screws etc and giving connection of water line and electrical supply. (Make Racold 6 litres Instant Water Heater, Pronto Stylo(491213632) or its equivalent). |
| 93 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe |
| 94 | 90.12.1.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm |
| 95 | 90.12.7.12:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp |
| 96 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 97 | OD350769/2025-2026:Supply, conveyance, installation, testing and commissioning of 40W LED post top lantern, body made of PDC aluminium spigot for mounting and heat sink for effective thermal management , IP66, IK10, control gear compartment accessed from top for ease of serviceability. Overall system High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W and L79 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having Circuit protection, Over Voltage protection, Surge Voltage protection upto 10 kV with SPD & other safety test as per IS 15885 Part-2/Sec 13.etc as required. |
| 98 | OD350774/2025-2026:Supply, conveyance, installation, testing and commissioning ofIP65 weather resistance, uses an E27 bulb base (max wattage varies, often 12W), runs on 220- 240V, and features a modern design with frosted glass for soft, diffused light(MODEL NO- Philips Chalet Gate Light (Post Top) or its equivalent)etc as required. |
| 99 | OD351392/2025-2026:Supply, installing and fixing on existing concrete foundation or Piller of Syntex junction box GSJB 1414 with provision for fixing SP/DP MCB for terminating cable |
| 100 | 90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm |
| 101 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 102 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 103 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 104 | OD198601/2025-2026:Supply and installation of ABC type fire extinguisher 5kg capacity consisting of M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30cm long high pressure discharge hose, nozzle etc and fixed on wall with using suitable size anchor fastener/screw with all accessories as required . |
| 105 | OD350784/2025-2026:Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required - 2.50 cm, 4 cm or 5 cm height |
| 106 | OD351282/2025-2026:Supply conveyance Installation testing and commissioning of inverter type wallmounting split AC unit ofthe following ratingsconforming to relevant ISsuitable for operating on230V, 50Hz, single phaseAC supply filled with R -410A or R32 refrigerant gas,high energy efficient, RoHScomplaint, capable ofperforming functions likecooling, dehumidifying, aircirculating, filtering etc. offollowing capacity includingrefrigerant copper piping3mtr with insulation,microprocessor controlwith cordless remotecontrol etc. - 1.5 TR 1 phase3 star rated inverter typesplit AC unit ( Carrier make)( Blue Star/ Daikin / Voltas) ( 1.5TON 3 STAR RATED AC ) |
| 107 | OD351283/2025-2026:Supply and Fixing of 4 KVA voltage stabilizer for split type A/C unit with voltagerange of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent) - |
| 108 | OD351380/2025-2026:Supply and fixing 25mm pvc drain pipe 10kg with all accessories in surface/recessincluding cutting wall and making good the damages etc as required. |
| 109 | OD351379/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA sine inverterworking by 24 Volt DC supply with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% and Short circuit,over/under voltage,surge & spike protections including giving connection etc (EXIDE/LIVEGUARD or equalent ) with supply and fixing of 2 Nos 12V 105 AH fully charged Lead acid Tubular Battery with terminal leads for the existing 2 KVA inverter unit (EXIDE or equivalent) including battery and inverter cabinet etc. as required. Please Enable Macros to View BoQ information |