| 1 | Dismantling and Taking up the following unseviceable/rusted ductile Iron water mains pipes laid in trenches or floor (including all fittings), with spigot and socket ends and lead joints complete all as directed :- |
| 2 | DI pipe 150 mm bore size |
| 3 | DI pipe 100 mm bore size |
| 4 | Supply and laying 150mm dia centrifugally cast (spun) ductile iron pressure pipes with double flanged end, class K-9 conforming to IS-8329/2000 (latest revision) with inside cement mortar lining and metalic zinc coating and outside black bitumen coating and having portland cement properties suitable for gasket joints including suitable size of rubber gasket, nuts, bolts and washer but excluding DI specials complete all as specified and directed. |
| 5 | All as per BoQ Serial item No.2 above but 100mm bore complete all as specified and directed. |
| 6 | M&L for rubber gasket joint for 150mm dia flanged DI pipe with gasket and suitable size of nuts, bolts and washer complete all as specified and directed. |
| 7 | All as per BoQ Serial item No.4 above but 100mm dia pipe, complete all as specified and directed. |
| 8 | Dimantling and taking up of old fittings and supply and fixing DI/CI specials, class K-12, both end flanged or both end spigot/socket or one end flanged and other end spigot/socket, any type such as bends, tapers, reducers, duck foot bend, tee pieces (single and double branch), etc including cutting of pipes for upto 150 mm dia ductile iron pipe (as per site requirement) complete all as specified and directed. |
| 9 | Taking up the following corroded/leakage MS pipes & connected unserviceable valves etc. of any size from trenches/ floors/walls for replacing with necessary fittings and valves etc complete all as specified and directed:- |
| 10 | MS pipe 150 mm bore |
| 11 | MS pipe 100 mm bore |
| 12 | MS pipe 80 mm bore |
| 13 | Supply and laying MS Pipes 150 mm dia heavy grade conforming to IS 1239:1990 with all fittings laid in floors or fixed to walls and ceilings etc including connections of pipe and valve by carrying out necessary welding, suitable size of nuts and bolts, washers etc for fixing rising pipe in high rise bldg and upto 6th floor with & including painting with two coats of synthetic enamel red colour paint over & including a coat of red oxide metal primer painted with electrical spray machine on directed location complete all as specified and directed .Note: (a) Care of labours for working on multistoried bldg shall be the responsibility of the contractor .(b) Pipe jointing material such as flange joints, bends, and supporting clamps on wall shall be measured and paid separately.(c) Self supporting steel scafolding required for working upto 7th floor shall be measured and paid seperately. |
| 14 | All as per BoQ Serial item No.8 above but for working in 7th floor to 12th floor complete all as spd and directed. Note: (a) Care of labours for working on multistoried bldg shall be the responsibility of the contractor.(b) Pipe jointing material such as flange joints, bends, and supporting clamps on wall shall be measured and paid separately.(c) Self supporting steel scafolding required for working from 7th to 12th floor shall be measured and paid seperately. |
| 15 | Supply and laying MS Pipes 80 mm dia heavy grade with flanged end conforming to IS 1239:1990 with all fittings laid in trenches or vertically in ground including necessary connection of pipe, welding/jointing complete all as specified and directed. |
| 16 | Supply and laying MS Pipes 100 mm dia heavy grade with flanged end conforming with all fittings laid in trenches or vertically in ground including necessary connection of pipe, welding/jointing complete all as specified and directed. |
| 17 | Supply and laying MS ERW Pipes 150 mm dia heavy with flanged end grade with all fittings laid in trenches or in ground including necessary connection of pipe, welding/jointing complete all as specified and directed. |
| 18 | Material and labour for construction of masonary inspection pit/valve pit of size 1200mm x 1200mm x 1000mm internally with Sub class \\"B\\" full brick thick brick work in cement mortor (1:6), 15 mm thick full plastering in CM (1:4) internally and externally upto 150mm below the ground level, 150mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregated) as in foundation bed with 150mm all round offset from outer side of brick work, 3 mm thick MS sheet cover with handle and locking arrangement hinged with 50 x 50 x 6 mm angle iron frame embeded in PCC (1:3:6) type C-1 (using 20mm graded stone aggregated) as in copings etc with & including painting with two coats of synthetic enamel paint over & including a coat of red oxide metal primer on steel surfaces including necessary earth work in any type of soil complete all as specified and directed. |
| 19 | S&F in replacement control wiring of MCP and hooter with 2 runs of 1.5 sqmm FRLSH PVC insulated copper conductor wire in 25mm PVC heavy duty casing caping complete all as specified and directed |
| 20 | S&F in replacement break glass type manual call point resettable type MS body fire red in colour complete all as specified and directed |
| 21 | S&F in replacement Mild Steel Fire Alarm Hooter, 24V, 100 M hooter red in colour complete all as specified and directed. |
| 22 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/ laying CI/GI/DI pipes and getting out in any type of soil complete all as specified and directed. |
| 23 | Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 24 | Removing excavated soil at a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 25 | M&L for cutting road/concreate surface for laying of DI/MS pipe not exceeding 150mm bore as directed by engineer-in-charge and making good of disturbed surface with PCC 1:3:6 type to match with the surroundings complete all as specified and directed. |
| 26 | S&F in replacement CI sluice valve of 150 mm dia, with stainless steel spindle conforming to IS:14846, PN 1.6 with matching flanges and connection with nuts, bolts and rubber gaskets complete all as specified and directed. |
| 27 | S&F in replacement ISI marked 150 mm nominal bore cast iron double flanged Non Return Valves as per IS : 5312, part- I, suitable for pressure 15 KG/cm2, including transportation to worksite, supply & fixing nuts, bolts, gaskets and washers etc. including testing complete all as specified and directed |
| 28 | Disconnecting/dismantling of old unsv fire hose box cabinet outdoor type and supply and fixing hose box made of 16 gauge MS Sheet 800mm X 600mm X 250mm (1.2 mm thickness) with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet (1.2mm thickness) duly painted fire red out side and brilliant white inside complete all as specifid and directed. |
| 29 | Disconnecting/ dismantling of old unsv fire hose box cabinet indoor type and suppply and fixing hose box made of 16 gauge MS Sheet 1200mm X 900mm X 450mm (1.20mm thickness). with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet (1.20mm thickness) painted with powder coated paint fire red on external /internal surfaces and fixed on floor/ wall of bldg complete all as specified and directed. Make : Minimax/Firex/Safex |
| 30 | S&F in replacement fire hydrant valve single headed conforming to IS-5290 with 80 NB flanged inlet, 63mm oblique outlet, stainless steel body, CI hand wheel FG-200 as per IS-210, phosphor bronze string IS-7608 complete all as specified and directed. |
| 31 | S&F in replacement rubber hose reel of 20mm external dia and 30 metre long inside the indoor type fire hos box cabinet with reel drum including stainles steel (SS) shut off nozzle conforming to IS 5132 complete all as specified and directed. |
| 32 | S&F in replacement 63 mm dia 15 meter long canvas non-percolating flexible delivery hose conforming to IS 636-1988 complete with SS male and female delivery coupling made conforming to IS 903 complete all as specified and directed. |
| 33 | S&F in replacement branch pipe SS 63mm instantaneous inlet, made threaded outlet,15mm bore nozzle short complete all as specified and directed |
| 34 | S&F in replacement SS adapter for 63 mm fire hydrant valve conforming to IS: 903 complete all as specified and directed. |
| 35 | S&F in replacement fire brigade inlet connection 150 mm dia, 4 way complete all as specified and directed. |
| 36 | S&F in replacement fire hydrant stand post, made up of 80 mm dia heavy duty MS pipe,1.5 mtr height, flanged type stand post position as per site requirment including new fibre board gasket and nut, bolt & washers complete all as specified and directedNote : Fire Hydrant valve shall be measured and paid separately. |
| 37 | S&F in replacement MS bend 150mm dia flange type long bend 90 (degree) with angle holes, nut bolts etc complete all as specified and directed |
| 38 | S&F in replacement flanged joints (complete set of two flange ) suitable for MS pipe 150mm dia with rubber or fibre board gasket, nuts, bolts etc complete all as specified and directed |
| 39 | All as per BoQ Serial item No.33 above but 80mm dia pipe. |
| 40 | M&L for providing plain cement concrete type C-2, (1:3:6) (using 40mm graded stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed. |
| 41 | S&F in replacement MS air release valve suitable for 150mm CI pipe to fix on raising main of respective blocks complete all as specified and directed |
| 42 | M&L for double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of both workers and the buildings having above 20m height complete all as specified and directed |
| 43 | S&F steel U-clamp with nuts and washers suitable for fixing of 150mm MS pipe with MS section /supports etc complete all as specified and directed. |
| 44 | S&F in replacement Sheet glass of 4mm thickness in hose box door, ordinary quality and glazing with oil putty in rectangular shape n exc 0.5 sqm in each pane complete all as specified and directed. |
| 45 | M&L for painting 150mm/100/80 mm bore MS pipe line old including valves fittings etc after removing old paind/rust from the surface by paint removers /scrapers etc over the surface of pipeline and painting with two coats of synthetic enamell red colour paint over & including a coat of red oxide metal primer painted with compressor operated spray machine as directed at location complete all as specified and directed |
| 46 | S&F in replacement Gun metal Gate valve 25mm dia complete all as specified and directed |
| 47 | S&F in replacement Pressure guage 4\\" dial having pressure rating 0-14 Kgs for fire fightiing system complete all as specified and directed. |
| 48 | Taking down carefully electric driven centrifugal pump set of any capacity from MS channels frame in foundation after disconnecting all pipes / main electric supply from motor starter panel and keeping the MS channel frame at site for repairs/painting and carrying the pump set to nearest repairing workshop including bring back after necessary repair complete all as directed. |
| 49 | M&L for overhauling of centrifugal pump installed at pump house with cleaning, greasing, minor repairs to pump & motor including replacement of spares parts like clamps, shaft sleeve, bearing, water ring, inter stage ring, PVC air vent, air release nozzles of brass for pump, water deflector, impeller check nut, body stud bolt & nuts, coupling PVC bush, SS nuts and bolts of iron full thread with washers, gaskets, etc & connected minor accessories including refixing all disconnected spare parts, checking for alignment with motor and reassembling complete all as specified and directed.Note: Major spares like impeller, shaft, stage bushing, coupling, ball bearing will be measured and paid seperately under respective items. |
| 50 | 110 HP 3 Phase . |
| 51 | 20 HP 3 phase . |
| 52 | Dismantling and opening the motor from 110HP pump set in existing position for carrying out to workshop for rewinding work with super enamelled copper wire of suitable gauge as per existing conforming to IS 13730 and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed. |
| 53 | Dismantling and opening the motor from 20HP pump set in existing position for carrying out to workshop for rewinding work with super enamelled copper wire of suitable gauge as per existing conforming to IS 13730 and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same with pump in original position complete all as specified and directed. |
| 54 | S&F in replacement 12 V DC battery 180AH complete all as specified and directed. |
| 55 | Supplying, fixing, testing and commissioning of local fire alarm control and indicating panel with mimic panel with indicating lights etc complete in all respects for proper working of the system and as per specifications. The control wires between the local control panel and the main control panel should be monitored and should give a fault indication at the Main Panel in the event of a fault complete all as specified and directed of the following zone:- |
| 56 | Control Panel 16 Zone |
| 57 | Control Panel 10 Zone |
| 58 | Control Panel 8 Zone |
| 59 | Comprehensive maint of fire fighting installation at Turf View complex for high rise buildings including minor repair of all spare parts of smooth operation/functioning of plant including greasing, cleaning, adjustment, minor repairs of nuts, bolts, washers, etc of centrifugal fire fighting & jockey pump sets etc with other related equipments of he pump house/ installation alongwith valves inlcuding cleaning of inside and outside areas of the respective pump house, replacement of gland packing, maint of suction and delivery pipe line, primary fill up of priming tanks at under mentioned location complete all as specified and directed.Note:- Comprehensive maint also include the fwg:-(i) Pressure testing of fire hydrant at different multistoried building.(ii) Daily maintenance of log sheet for pumping set for both electric and diesel engine driven. |
| 60 | S&F in replacement copper lead for battery consisting of 2 Nos 1.5 mtr long cable of colour red and black having cable size 25 sqmm complete all as specified and directed. |
| 61 | S&F in replacement battery charger of charging capacity of 24 volt 180 AH (2x12Volt) battery dully fixed in panel/wall complete with provn of necessary connection complete all as specified and as directed. |
| 62 | S&F in replacement overload protection relay suitable for FASD starter relay range and current capacity 160 A Max complete all as specified and directed. Note : The relay should have competable with the existing motor starter of different makes. |
| 63 | S&F in replacement 3 pole power contactors 160A, AC-1 and AC-3 95A rating ,415V, 50 HZ complete all as specified and directed. |
| 64 | S&F in replacement 3 pole power contactors 40A, AC3 & 55A, AC1 rating, 415V, 50 HZ and IS/IEC-60947-4-1 suitable for fully automatic star-delta starter complete all as specified and directed. |
| 65 | S&F in replacement MCCB, 415 Volts, 35 KA breaking capacity, 4 pole, 200 Amps complete with adjustable themal and fixed magnetic setting complete all as specified and directed. |
| 66 | S&F in replacement mild steel channel or angle iron 50x50x6 mm grade Fe 310-0 as in base frame for pump foundation complete all as specified and directed. |
| 67 | S&F in replacement Powder Fire Extinguisher (Stored Pressure type) Capacity 09 Kg duly ISI marked conforming to IS: 15683:2006, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30ºC to + 60ºC complete all as specified and directed. |
| 68 | S&F in replacement Automatic Star Delta Starter, 3 Phase, 415 V AC, 7.5HP/5.5KW, Coil Voltage 415 V AC 50Hz with overload relay range 5.5-8.0A, AC3 rating 10A, and contactor LC1D17/16A which mounted on indoor type LT Feeder panel of size (625mm (L) x 325mm(W) x1175mm (H) with MS base channel frame (Without Canopy).The feeder pillar shall be made out of 2.0mm thick CRCA Stainless steel sheet for outer shell and 2.0mm thick for inner doors / partations and 3.00mm thick gland plate and having compartmentalized construction) suitable for 7.5 HP electric driven Centrifugal Fire fighting Jockey Pump complete all as specified and as directed. Location : Pump House of TV near Block No 19 |
| 69 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 metre below normal ground level with top edge of the plate not less then 1.50 metre below normal ground level connected to galvanized earth 32mm x 6 mm GI strip by means of bolts, nuts, check nuts and washers complete up to and including test point made out of 40 x 6mm aluminium flat including excavation in any type of soil for earthing pit, charcoal, common salt 25mm dia medium grade GI watering pipe, PCC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (Part-I) complete all as specified and as directed.NOTE: Main earthing lead & protection pipe 40 mm dia light grade from earth electrode to test point upto 7.5 mm is deemed to be included in quoted unit rate. Please Enable Macros to View BoQ information |