| 1 | Demolition of cement concrete (unreinforced) in roof/terrace other than ground floor etc, including existing roof treatment of any description not exceeding 15cm thickness as directed and specified. |
| 2 | M&L for rendering 10mm thick in cement mortar 1:3 mixed with integral water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement all as specified and direct. |
| 3 | M&L for 25mm thick cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in roof top etc complete all as specified |
| 4 | Supply & providing water proofing roof treatment with polymeric standard water proofing membrane, Aqua flex manufactured by M/s Bengal Bitumen, MULTIPLAS STANDARD, manufactured by STP TEXAS Ltd/ Hyperplas manufactured by IWL Ltd or equivalent as approved by EIC, having 10 years guarantee for water tightness complete all as specified and described as under:-(a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufacturer's specification complete all as specified and directed.(b) Supply & providing water proofing with 3 mm thick APP polymeric proofing membrane of 3Kg/Sqm HYPERPLAS STANDARD/ MULTIPLAS STANDARD consisting of 100 micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed (c) Aluminium bituminous paint @0.15 Kg/Sqm shall be applied over the APP membrane surface. NOTE:- The work of water proofing treatment shall be got executed only through authorised applicator certified by Manufacturer's. |
| 5 | Dismantling of Asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings etc complete all as specified and as directed. |
| 6 | S&F 0.50mm thick (including coated thickness) pre-colour pre- profiled (Galvalume/zinkalume) sheets of required colour and design having tensile strength of 550 Mpa as in roof sheeting/sunshade/ wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer / profile maker instruction complete all as specified and as directed. |
| 7 | Dismantling of timber scantlings as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in un-framed work complete all as specified and directed. |
| 8 | M&L in for MS steel Hollow Section work in tubular trussles, purlins, rafter, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc, complete using ERW or induction butt welded tubes conforming IS-4963,1993 and IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 9 | M&L in for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming IS-1161-1979 grade ST-240 complete all as specified and as directed. |
| 10 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed |
| 11 | S&F for Anodised aluminium snap grid size (605mmx605mm) frame work for false ceiling with Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.(Make: ISI and Equivalent) |
| 12 | M&L for Exposed metal frame ceiling with 4mm calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) complete all as specified.(Make: ISI and Equivalent) |
| 13 | S&F PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet 8 to 10 mm hollow section inclusive of solvent cement and fixing at site on PVC frame as per specifications and Manufacturer instruction, including taking down of old board, complete all as specified and directed. |
| 14 | S&F PVC Ceiling Lining (False Ceiling) incl frame work for PVC Ceiling consisting of 5mm thick Plain colour PVC sheet 8 to 10 mm hollow section inclusive of solvent cement and fixing at site on frame work as per requirement on site complete all as specified |
| 15 | S&F Gypsum Board 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre on GI frame work for seamless ceiling comprising of GI perimeter chennel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm susoended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with clips of 10.5mm fixed to the intermediate channel at 457mm centre to centre inluding finishing the joint of face board with specially formulatted jointing compound and 48 mm wide fibre tape to provide seamless finish Ceiling shall be sealed at joints and finished with jointing compound etc complete including finishing the exposed surfaces of false ceiling with two coats of plastic emulsion paint over a coat of primer complete all as specified and directed. |
| 16 | Providing and fixing PVC SHEET WALL PANELLING of thickness 5mm ( ±0.25 ) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm ( ±0.25 ) thick Prelam PVC sheet. The panel & strips shall be Density of 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company. The strips should have in their center a grove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm ( ±0.25 ) thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement. This wall panaling consisting of PVC insulated panels having wall thickness of 2mm ( ±0.2 ) PVC sheet of Density 600 Kg /Cbm Manufactured by an ISO-9001-2015 certified Company, and the desired thickness of EPS ( Dependent on the Insulation Required ) screwed into the wall using screws of adequate length. The screws shall be placed at a distance of 150mm and shall be 25mm from the edge of the insulated panel on all four sides of the panel. The PVC Strips of 5mm ( ± 0.25 ) thick PVC Sheet of width 75mm feathered at the edges shall be stuck using solvent cement adhesive at the places where two panels are joined, so as to cover the screw of both the panels, using solvent cement. 900 heat bent strips of 5mm thick PVC sheets of width 75mm x 75mm feathered at the edges shall be stuck at wall joints / pillars etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. (Make- RAJSHRI or equivalent as approved by GE) |
| 17 | S&F 12mm thick Frosted Toughned Glass fixed on patch hinges/pivot for smooth functioning in door shutter including stainless steel handle of 8 inches long and mortice locking arrangement complete all as specified and as directed |
| 18 | S&F up to 10mm thick Polycarbonate sheet in dome structure/similar condition with rubber neoprene/similar packing material fixed and packed with sheet including dismantling of existing sheeting complete all as specified and as directed. |
| 19 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 20 | Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 21 | M&L for rendering 15mm thick in CM 1:4 on External faces (Exposed to weather) of brick or concrete surface of wall with liquid water proofing compound @ 200 ml per bag and finished even and smooth without using extra cement complete all as specified and as directed. Note:-(a) The Cost of Liquid water proofing compound included in the iteam and not to be paid separately |
| 22 | M&L for rendering 10 mm thick in CM ( 1:6 ) on Internal faces of brick or concrete surface of wall and finished even and smooth without using extra cement complete all as specified and as directed |
| 23 | M&L for rendering 5mm thick in ceiling CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 24 | M&L for applying two coats of first quality oil emulsion distember over a coat of primer over a coat of Acrylic / Water proofing wall Putty on walls complete all as specified . Note:- Putty shall be measured and paid seperately under relevant item. |
| 25 | Material and labour for New plastered surfaces of wall,pillasters, cornices etc precoat treatment apply two coats of Anti fungal weather coat aacrylic emulsion paint over a one coat of wall care acrylic putty and apply coat of primer (X2) complete all as specified and directed Make of Arcylic emulsion weather coat paint :- Asian (Apex Ultima), Berger (Super coat) or ICI Dulux (weather shield) Make of primer :- Asian (X2) or Equivalent Note :- (a) Each stage i.e preparation of surfaces,application of primer,application of first coat. application of second coat will be got passed from Engr-in-Charge (b) Written Warranty for four years or as per manufacturer's instructions, whichever is more is required to be furnished by contractor for this item (c) Putty shall be measured and paid seperately under relevant item. |
| 26 | Preparation of old decorated surfaces of wall including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying one coat of exterior weather proof water base emulsion paint white/coloured over primer of same make white cement based putty (where it is required in patches) all as specified and directed. Putty shall be measured and paid seperately under relevent item).Make Asian- Apex or Equivalent |
| 27 | Preparation of old decorated surfaces of wall including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying and applying two coat of Acrylic Smooth exterior paint of required shade (@ 1.67 ltr/10 sqm) over over a coat of primer(@ 2.20 kg/10 sqm) same make base white cement based putty (where it is required in patches)all as specified and directed. Make Asian- Apex or Equivalent. Putty shall be measured and paid seperately under respective item) |
| 28 | M&L three coats of white washing on newly/Old plastered or concrete celling sufaces incuding preparation of surfaces. |
| 29 | M&L for removal of complete existing treatment of Internal/External wall and surface finished even and smooth with sand paper complete all as specified and directed. Note: Complete Removal is to be carried out upto 15.00m height .The contractor is advised to visit the site before quoting the tender.The rate quoted by contractor will deemned to be inclusive of necessary sacffolding work etc required at site. |
| 30 | M&L for preparation of newly plastered surface of wall and and applying 2mm thick Acrylic / water proofing wall putty in two coats (each coat not less than 1mm thick ) and surface finished even and smooth with sand paper complete all as specified Please Enable Macros to View BoQ information |