| 1 | Providing motor and Electrification |
| 2 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 3 | 90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet |
| 4 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 5 | OD45822/2026-2027:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 100milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 6 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 7 | 90.14.24.2:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. |
| 8 | OD27565/2026-2027:Supply and fixing Digital multi functional meter |
| 9 | OD49369/2026-2027:Supply,installation,testing and commissioning of 5HP vertical open well submersible motor pump set 2900 RPM at rated voltage,3 phase 415v,50Hz AC Supply at max 125 Head range of model 6 stage 5DX/6, Deccan make (Bronze impeller and star/Delta connection) equivalent delivery size 50mm having discharge 10500 LPH at 89 mtr head using leak proof materials as required and suspended on 1 run 10mm stainless steel rope including fixing 80 sedulous ASTM delivery pipe connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary supports on both sides of the motor including giving connections as per the direction at site.(5 star rated). |
| 10 | OD45687/2026-2027:S & F Motor starters of the following ratings.L&T MK1,DOL Motor starter Relay scale 11-18A ,360V with isz5 380V Single phasing preventer ,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL).Cat:No:SS96211COCO. |
| 11 | OD27571/2026-2027:Supply and fixing Single phasing cum dry running preventer relay. |
| 12 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 13 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 14 | OD27580/2026-2027:Supply and providing Red,Green,Blue,Yellow,Orange colours LED indicators ,AC/DC 22.5mm cut out dia. |
| 15 | 2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N |
| 16 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 17 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 18 | OD27570/2026-2027:Supply and providing 25x3mm brass Nut and Bolt as required. |
| 19 | OD27558/2026-2027:Supply and providing 25x6mm brass Nut and Bolt as required. |
| 20 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 21 | OD27568/2026-2027:Providing and fixing 2x25x3mm GI strip on surface or in recess for connections etc as required. |
| 22 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 23 | 1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm |
| 24 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 25 | 1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 26 | OD27562/2026-2027:Supply and laying 12mm or nearest size GARFIL/GARWARE nylon rope |
| 27 | OD27557/2026-2027:Supply and laying 10mm or nearest size stainless steel rope. |
| 28 | OD27556/2026-2027:Supply and fixing 63A,HRC fuse with HRC fuse link with connections in existing Meter board. |
| 29 | OD27581/2026-2027:Supply and fixing 63A 2 way neutral link mounted on DMC/SMC base with connections,in existing meter board. |
| 30 | OD27573/2026-2027:Supplying and fixing 1 amp to 2 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 31 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 32 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 33 | OD27575/2026-2027:Supply and providing 9W LED lamp in the existing fittings as required. |
| 34 | OD27563/2026-2027:Supply and installation of dust and vermin proof,3 phase syntax Meter Board (GS-MB-5628) and to fix KSEB Meters,fuse units,etc as required(560x280 IP 55)including fixing it on wall,making good the damages colour washing etc. as required. |
| 35 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 36 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 37 | OD27576/2026-2027:Aluminium anodized Danger Notice Board of size 200X150mm with inscriptions (both in English and Malayalam) and conventional Skull and Bone in Rad colour. |
| 38 | OD27579/2026-2027:Supply and fixing suitable pressure gauge in the delivery side of the pump |
| 39 | OD27564/2026-2027:Supply and Providing 50 mm dia Full way Wheel valve( GM -ISI ) |
| 40 | OD27569/2026-2027:Supply,threading,laying and jointing of 50mm dia 80 sedulous ASTM pipe approved make with specials as delivery pipe using required leak proofing materials etc as required. |
| 41 | OD27566/2026-2027:Supply and providing 50mm flange set |
| 42 | OD46319/2026-2027:Supply and providing 65 mm flange set |
| 43 | OD46318/2026-2027:Supply,installation,testing and commissioning of 65 mm KARTAR DI NRV F/E GM SEAT PN16 in the existing PVC/ASTM Pipe.(Gun metal mechanism and Cast Iron Body. |
| 44 | OD27574/2026-2027:Supply and fixing flat iron clamps made of 40x6mm flat iron clamp of 40cm with suitable size bolt and nut for fixing delivery pipe on top of the well including painting as required. |
| 45 | OD27577/2026-2027:Providing ,Laying and fixing 50 dia GI pipe (Medium class) for supporting the delivery pipe on the top of the well , the pipe placing across the well and clamping each other using required accessories etc. |
| 46 | OD27572/2026-2027:Supply and providing suitable iron hook grouted on wall for binding the service wire. |
| 47 | OD27567/2026-2027:Charges for procurement,preparation and submission of application for availing Single/Three phase KSEB service connection with necessary sketch.Test and completion report,stamp fee etc.including necessary liaison work as required. |
| 48 | 90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps |
| 49 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 50 | 1.17.32:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 6 sq. mm |
| 51 | 1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm Please Enable Macros to View BoQ information |