| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.(a) Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form forWeather shed, Chajjas, corbels etc., including edges |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.(a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | 12 mm cement plaster of mix1:4 (1 cement: 4 coarse sand) |
| 8 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 9 | 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) |
| 10 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 11 | White washing with lime to give an even shade (a) New work (three or more coats) |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (a) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 13 | Finishing walls with water proofing cement paint of required shade :(a) New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 14 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:(a) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 15 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :(a) Of area 3 sq. metres and below |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:(a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 17 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(Note: Butt hinges and necessary screws shall be paid separately)(a) Second class teak wood35 mm thick shutters |
| 18 | Paintting with oil type wood preservative of approved brand and manufacture:(a) New work (two or more coats) |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 20 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 21 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.(a) Bend 87.5°110 mm bend |
| 22 | (b) Shoe (Plain)110 mm Shoe each |
| 23 | Regrading terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of thenew tiles or brick excluded), all complete as per direction of Engineer-in- Charge. |
| 24 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 25 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
| 26 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x 250 mm |
| 27 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall(a)15 mm dia nominal bore |
| 28 | (b)20 mm dia nominal bore |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc., complete.a)Size of Tile 600x600 mm |
| 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sgm including pointing the joints with white cement and matching pigment etc., complete. |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to 1S: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(a) Fixed to steel windows by welding |
| 33 | Providing and fixing bright finished brass casement window fastener withnecessary screws etc. complete. |
| 34 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nutsand screws etc. complete (Copper oxidised as per IS 1378)300x16 mm |
| 35 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : a) In 75x75 mm deep chase |
| 36 | Making khurras 45x45 cm with average minimum thickness of 5 cm cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finishedwith 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coatof neat cement, rounding the edges and making and finishing the outletcomplete. |
| 37 | Total Rs. 3,09,834.06 |
| 38 | GST correction factor @ 0.973 =Rs. 3,01,468.54 |
| 39 | Cost index 4.03% |
| 40 | Total Civil Work ‘A’ Rs. 3,13,617.73 |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 42 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(Group A) |
| 43 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. |
| 44 | 3*1.5 Sq mm |
| 45 | 3*4 Sq mm |
| 46 | 3*6 Sq mm |
| 47 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 48 | 5/6 A switch |
| 49 | 15/16A switch |
| 50 | 3 pin 5/6 A socket outlet |
| 51 | 6 pin 15/16 A socket outlet |
| 52 | Bell push |
| 53 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 54 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 55 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V. complete as required. |
| 56 | Supplying and fixing of 3mm thick phenolic laminates sheet |
| 57 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheetsteel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 58 | For 8 way, Double door SPN MCBDB |
| 59 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 60 | 8 way , Double door |
| 61 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 62 | Single pole |
| 63 | Double pole |
| 64 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 65 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 66 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 67 | Total (A+B) (Civil Works + Electrical Works) Rs. 3,69,833.73 Please Enable Macros to View BoQ information |