| 1 | Dismantling posts or struts (wood,steel or RCC.) any section,including taking out embedded portion and making good disturbed natural ground, complete all as specified and directed. |
| 2 | Excavating in post holes(or similer holes) each n exc 0.5 cum getting out,returning filling in and raming earth or broken rubble mixed with earth around,in layers not exceeding 25 cm, complete all as specified and directed. |
| 3 | M&L for cement concrete type C-2 1:3:6 using 40mm graded stone aggergate as in foundations filling and mass concrete, complete all as specified and directed. |
| 4 | S&F mild steel work posts and struts in fencing including cutting tops to shape as directed ,drilling holes,notching for wires, etc, flat iron fillets(for securing wire mesh etc.) including all necessary drilling,bolting or riveting etc.and similer work conforming to Fe-290 Gde E-165 (For Fencing), complete all as specified and directed. |
| 5 | S&F in Repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strainging bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or stel pins, etc, complete all as specified and directed. (each line wire to be measured) |
| 6 | Dismantling fencing wire mesh,any type (for Chain link Fencing), complete all as specified and directed. |
| 7 | Supply only chain link MS galvanated fencing any size fixed to any type of stander rail n exc 3 kg per sqm, complete all as specified and directed. |
| 8 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. |
| 9 | S&F mild steel security chain link fencing 60mmx60mm with PVC coated mesh made out of 3mm dia MS wire and 1.00mm thick PVC coating throughout fixed to RCC post including binding wire complete all as specfied and directed. |
| 10 | S&F Tie bars with screwed ends, nuts, washers and mild steel paltes for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed. |
| 11 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10 cm long diameter of the neck in 5 to 10 mm, complete all as specified and directed. |
| 12 | S&F Mild steel Round bars 10mm dia and over,cut to length, bent to shape required, complete all as specified and directed. |
| 13 | Dismantling wrought iron work or mild steel work of any description, complete all as specified and directed. |
| 14 | S&F Framed mild steel work of grade E-165 (Fe-290) as in framed work such as doors, gates or frame for cooler stand with gusset plates, rails, braces etc, drilled for fixing of sheeting or other covering of door etc, to be prepared for hanging or sliding etc including either hooks and hinges or steel hanging door fittings and hanging and fixing, complete all as specified and directed |
| 15 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc; under 40 sq. cm in each section, fixed in any position as in framed work complete all as specified and directed |
| 16 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 17 | S&F Pre painted galvatume aluminum zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 18 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed |
| 19 | Preparation of old decorated surface of steel/Iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 20 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins, arches, pillars etc, complete all as specified and directed. |
| 21 | M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4) complete all as specified and directed. |
| 22 | All as per item no 21 above but using old bricks retrieved from demolition above including cleaning and removal of mortar from old bricks etc complete all as specified and directed. |
| 23 | Taking down cement plaster on brick walls of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 24 | M&L for rendering 15 mm thick in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and fair. complete all as specified and directed |
| 25 | M&L preparation of new plastered or unplastered surfaces and applying two coats of cement based paint over a coat of chalk white primer on walls. complete all as specified and directed |
| 26 | Demolition of un-reinforced cement concrete in any position complete all as specified and directed |
| 27 | M&L for 40 mm thick cement concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in roof, sub base of flooring,surface finished rough to receive floor topping, complete all as specified and directed. |
| 28 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in lintels upto 1.50 metre clear span,cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works, complete all as specified and directed. |
| 29 | Demolition of reinforced cement concrete (reinforce-ment cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing debris outside MD land, complete all as specified and directed. |
| 30 | M&L RCC nominal mix 1:2:4 type B1 using 20mm graded aggregate as in Precast cover slab , shelves and similar articles and setting in cement mortar of 1:6 complete with joints to match, complete all as specified and directed. |
| 31 | M&L for Cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection/path, 75mm thick, surfaces finished even and fair without using extra cement as in plinth protection/path including provision of construction joints, complete all as specified and directed. |
| 32 | M&L for 50mm thick Cement concrete type D-2, 1:4:8 as in sub base complete all as specified and directed |
| 33 | M&L for Sand filling under floors or in foundation complete all as specified and directed |
| 34 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade with grey cement & no pigment complete all as specified and directed |
| 35 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed |
| 36 | M&Lfor Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry With grey cement and pigments in floors over 15 mm thick screed bed 1:6 complete all as specified and directed. |
| 37 | M&L for Granite(of any type) tiles18- 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick plaster as in back coat CM 1:4 complete including making circular gas pipe hole, moulding at corners and polishing type complete all as specified and directed. |
| 38 | M & L for non skid coloured ceramic endura tiles heavy duty for outdoor 7 to 8 mm thick , area of each tile exceeding 0.06 sq m but not exceeding 0.11Sq m in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over include 15 mm thick cement screed in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and as directed. |
| 39 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever equired, complete all as specified and directed. |
| 40 | M & L for providing precast cement concrete louvers and jalies, 25 mm thick type B0 1:2:4 (12.5mm graded aggregate) (measured solid), Set in CM 1:4 including all moulding but excluding frames, complete all as specified and directed. |
| 41 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete , using extra cement , including forms , moulds, mitred/ stopped ends etc, complete all as specified and directed. Please Enable Macros to View BoQ information |