| 1 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 2 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed. |
| 3 | Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed. |
| 4 | M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed. |
| 5 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick ( Below or above ground) complete all as specified and directed. |
| 7 | M&L for providing 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base, complete all as specified and directed. |
| 8 | M&L for chequered cement concrete tiles 20cmx20cmx25mm in floor, with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over and including 15mm thick screed bed in cement mortar (1:6) complete all as specified and as directed. |
| 9 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed. |
| 10 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed. |
| 11 | M &L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valley complete all as specified and as directed. |
| 12 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work and including dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed. |
| 13 | S&F for 4mm thick, plywood (No. of ply3), grade BWR,type BB, fixed with nails to timber frame work on wall including taking out old plywood of any description complete all as specified and as directed. |
| 14 | S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid and including demolition of old one complete all as specified and as directed. |
| 15 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 16 | S&F rolled mild steel, Fe 410-W (Gde E-250) quality - A, joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed. |
| 17 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracketframing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe 410-W (Gde E-250) quality - A,., complete all as specified and directed. |
| 18 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 19 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 20 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 21 | Supply only integral water proofing compound complete all as specified and as directed. |
| 22 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 23 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 24 | M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 25 | M&L for preparation of old wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel complete all as specified and as directed. |
| 26 | M & L for preparation of new steel surface over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 27 | M&L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed. |
| 28 | Demolition of cement concrete (unreinforced) of any description and in any position provided, complete all as specified and directed. |
| 29 | M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed. |
| 30 | Taking down shutters of any description n exc 1 sq.m each complete all as specified and as directed. |
| 31 | Taking down shutters of any description exc 1 sq.m and n exc 2 sq. m each complete all as specified and as directed. |
| 32 | S&F Factory made 30mm thick flush shutter solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified and as directed. |
| 33 | S&F 30mm thick factory made second class hard wood glazed and skeleton shutters for windows,ventilators, etc. are provided with stiles and rails, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (without sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed. |
| 34 | S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 35 | S & F 100 mm size butt hinges, heavy weight, cold rolled mild steel, and fixed, complete all as specified and as directed. |
| 36 | S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 37 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 38 | S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 39 | S&F in repairs, harrison rails 19/20mm dia, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 40 | S & F in repairs, Vitreous China Squatting Pan\\"Orissa pattern\\" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed. |
| 41 | S & F in repairs,10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets, 15mm dia PVC connection pipe etc complete all as specified and as directed. |
| 42 | S & F in repairs, vitreous china wash hand basin, white flat back size 550 mm x 400 mm including brackets including pillar tap, 15 mm bore chromium plated, cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe,15mm dia PVC connection pipe complete all as specified and as directed. |
| 43 | S&F in repairs, bib taps 15mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as specified and directed. |
| 44 | S&F in repairs, stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe. |
| 45 | S & F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking out old tube of any description complete all as specified and as directed. |
| 46 | S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including taking out old tube of any description complete all as specified and as directed. |
| 47 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 48 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 49 | All as per item serial No 48 here-in-before but for One 3 pin 5 Amp socket combination on independent board with other switches. |
| 50 | All as per item serial No 48 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 15/16 Amp socket outlet on independent board. |
| 51 | S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 52 | S & F switch socket combination outlet 3pin, 2-in-1, 5 Amp flush type complete all as specified and as directed. |
| 53 | S & F switch socket combination, multipurpose, 2 in 1, 3pin, 5 & 16 Amp flush type complete all as specified and as directed. |
| 54 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 55 | S & F in repair LED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as directed. |
| 56 | S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 57 | S&F MCBs, SPN/DP 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 58 | S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 59 | M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: For payment purposes, 2 runs of main cable (each of 1RM) 1 run of earth continuity cable (1RM) and one run of conduit (1RM) all together shall be considered as \\"1RM\\". Please Enable Macros to View BoQ information |