| Sl. No. | Item Description |
| 1 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 125 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge. |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each each as doors, windows and ventilators and removal from site complete all as specified and directed. |
| 3 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid flush door shutter of 30 mm thick , size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long handle complete all specified and directed by Engineer -in-charge. |
| 4 | Supply & Fixing Factory Made 30mm thick Solid WPC ( Wood polymer Composite ) Wiremesh Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension rade ), calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cum , having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter for fixing Mosquito mesh and XTN aluminium mesh together on panel area of door except stiles and rails to be panelled with and including mesh with self tapping round headed scresws at required distance, screws and edges covered with feathered pvc edge beading all around of mesh and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws with and including 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainles steel handles, 125 mm long, (ISI marked) , 01 No. of helical door spring of 300 mm length complete all as specified and as directed by Engineer-in-charge. Note: 1. Material test certificate of all the items and authentication should be compulsory provided by the manufacturing company 2. The rate of 03 Nos door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos stainless steel barrel tower bolts of extrude section, 150mm long (ISI marked), 2 Nos stainles steel handles, 125 mm long, (ISI marked) , 01no. of helical door spring of 300 mm length is inclusive in this item and nothing shall be paid extra on this item..3. The rate of Mosquito mesh and XTN aluminium mesh is included in this item and nothing shall be paid extra on this account. |
| 5 | Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge. |
| 6 | Supply & fixing aluminium anodised sliding door bolts 300mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge. |
| 7 | Supply and fixing anodised aluminium handle, fabricated type 150mm long complete all as specified & directed by Engineer-in-charge. |
| 8 | Supply & fixing repairs 300mm mild steel ordinary rat tail rod springs (helical spring) , including roller & roller plate, fixed with screws/welding to steel frames/chowkats, complete all as specified and as directed by Engineer-in- charge. |
| 9 | Supply and fixing factory made uPVC white colour (Fixed) window / ventilators of area not exceeding 1.00 Sqm each window / ventilator made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 10 | Supply and fixing factory made uPVC white colour casement Sliding) window / ventilators of area exceeding 1.00 Sqm but not exceeding 2.0 sqm each window / ventilator made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 11 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each as doors, windows and ventilators and removal from site complete all as specified and directed. |
| 12 | Material and labour Anodised aluminium grill (anodised transparent of dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 13 | Supply & Fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks to stainless steel wire staple complete all as specified and as directed by Engineer-in-charge. |
| 14 | Supply & fixing for 4 mm thick, sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge. |
| 15 | Material and Labour Forming jambs, etc. to openings , including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in Cement Mortar 1:4 , complete all as specified and directed. |
| 16 | Supply & fixing Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engineer-in-charge. |
| 17 | Material and Labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over with and including one coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-charge. |
| 18 | M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed in CM 1:6 complete all as specified and directed. |
| 19 | Material and Labour for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge. |
| 20 | Material and Labour for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge. |
| 21 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the permises etc. complete all as specified and directed by Engineer-in-charge. |
| 22 | Material and labour for 10 mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces for receiving of wall tiles complete all as specified and directed by Engineer-in-charge. |
| 23 | Material and labour for Screed bed or bedding layer of 1:6 cement mortar 15 mm thick for laying floor finsihes complete all as specified and directed by Engineer-in-charge. |
| 24 | Material and labour for 15mm thick Screed bed or bedding layear in Cement mortar 1:3 on roof surfaces, parapet or vertical beam surface (horizontal or Vertical) finishing the surfaces even and fair complete all as specified and directed by Engineer-in-charge. |
| 25 | Material and labour marble work (Udaipur green slabs) in one piece not less than 18mm to 20 mm thick (table rubbed and polished) as in cooking platforms and like in laid over and including 15 mm thick screed in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade and roundening to the edge of stone slabs on edges etc. complete all as specified and as directed by Engineer-in-charge. |
| 26 | Material and labour for machine cut kota stone slab flooring 20-25 mm thick laid over with and including 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and Labour for 20-25 mm thick Kota stone slab as approved by GE in riser of steps, stairs, skirting,dado etc. over with and including rendering 20 mm hick in cement mortar 1:6, laid and jointed with grey cement slurry @ 3.00 Kg/ Sqm mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed by Engineer-in- charge. |
| 28 | Material and labour for roof treatment:-(a) Removal of any type of existing roof treatment such as brick tiles,mud phuska, APP membran in any number of layer up to orignal RCC roof top slab surface (b) Clean the roof:- Clean the roof: preparation of surface by scrapping and properly cleaning the existing surface by removing loose / uneven particles with wire brushes and other tools, complete in all respect as directed by Engineer-in-charge. (c) Material and labour for applying of liquid water proofing treatment to RCC roof slab described as under: (i) Apply first coat of Fiber reinforced elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 MPa and shall have crack bridging ability upto 2.5 mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree Celsius with 33% dilution as priming coat.(ii) Laying of fiber mesh of 0.3mm thickness weave in leno pattern having weight 45 gm/Sqm and pasting it properly with overlap of 50mm and allow it to dry.(iii) Apply second of undiluted coat @ 0.450ltr/sqm. (iv) Apply third and final coat undiluted @ 0.450 ltr/Sqm as directed by Engr-in-Charge.(d) Ponding Test:- Ponding test shall be done after application of material.Notes :-(a) Application of water proofing treatment will be done by Authorised Applicator only/or in presence of auth rep as approved by GE . Certificate in this regard shall be submitted to Engr-in-Charge.(b) Shifting/removing of any wire/cable/AC unit or other any object as per site requirement and re-fixing the same if needed is deemed to be included in the rate quoted by the contractor. (c) Total removal of vegetation/creepers//small plants/roots from the top of the bldgs to facilitate the work of treatment is also deemed to be included in the rate of contractor. |
| 29 | Material and Labour for 40mm average thick PCC padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair using Liquid water proofing compound complete all as specified and directed. Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ. |
| 30 | Supply only liquid water proofing compound complete all as specified and directed. |
| 31 | Material and labour Brick work with sub class ‘B’ old size burnt clay bricks straight or curved on plan exceeding 6 metre mean radius built in Cement Mortar 1:6, complete all as specified and as directed by Engineer-in-Charge . |
| 32 | Material and labour for Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan to any radius in half brick walls built in Cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 33 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engineer-in-charge. |
| 34 | Material and labour for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 35 | Material and labour for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 36 | Material and labour for rendering 5 mm thick in cement mortar in (1:3) on ceiling and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 37 | Material and labour for applying three coats of white wash on newly plastered or unplastered ceiling surfaces including preparation of surfaces, complete all as specified and as directed by Engineer-in-charge. |
| 38 | Material and labour for preparatoin of old suraces of ceiling and appling one coat of white wash complete all as specified and as directed by Engineer-in-charge. |
| 39 | Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge. |
| 40 | Complete removal of existing treatment on Old Internal wall surfaces of any description, preparation of surface by Mechanised sander having suction vacuum Bag using Smart periodical methodology, complete all as specified and applying the following :-(a) Material and Labour for wall care putty (2mm thick) in two layers (each layer 1mm thick ) on wall surface and smoothening the surface with sand papers / Mechanised sanding etc preparatory to paint as directed complete all as specified(b) Material and Labour for two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on old prepared surface by using Airless spray / Roller complete all as specified.Note:- 1.Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.2. Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 41 | Preparation of new plastered Internal wall surface complete all as specified complete all as specified and applying the following:-(a) Material and Labour wall care putty (2mm thick) in two layers (each layer 1mm thick ) on wall surface and smoothening the surface with sand papers / Mechanised sanding etc prepatory to paint as directed complete all as specified.(b) Material and Labour two coat of acrylic emulsion distemper over a coat of chalk whitening priming by using Airless spray/Roller complete all as specified.Note:- 1.Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.2. Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 42 | Material and Labour for preparation of new surfaces by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and wall care putty (2mm thick) in two layers ( each layer 1mm thick ) complete all as specified and directed.Note : Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 43 | Material & Labour for complete removal of existing treatment of any description on old wall surafce of any description of surface by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and wall care putty (2mm thick) in two layers ( each layer 1mm thick ) over new surfaces.complete all as specified and directed by the Engineer-in-Charge.Note : Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 44 | Supply and fixing in repair bib taps cost copper alloy with crutch or butterfly handle , screwed down , chromium plated screwed for iron pipe or brass ferrul for 15MM bore dia pipe complete all as specified and director. |
| 45 | Supply and fixing 15mm bore Stop valves, fancy type, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 46 | Supply and fixing 15mm bore Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 47 | Supply & fixing Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 25mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. |
| 48 | Supply and Fixing 15mm bore chromium plated, quarter turn Pillar cock screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed by Engineer-in- charge. |
| 49 | Supply & fixing in repairs chromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge. |
| 50 | Supply & fixing in repairs PVC waste pipe of 32/40mm dia with socket suitable for connection to Waste fittings , and of length minimum 75 cm complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply & fixing PVC connections 15mm size with brass nuts of length 450mm complete all as specified and as directed by Engineer-in-charge. |
| 52 | Material and Labour for in repair vitreous china wash down water closet pan wall hanging single piece (with and including flushing cistern EWC) 'P' trap, with and including white coloured closed pattern plastic seat cover, hand faucet , with and including mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge. |
| 53 | Supply and Fixing wash hand basin of size 550mm x 400 mm vitrous China white flat back including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete complete all as specified and as directed by Engineer-in-charge. |
| 54 | Supply and Fixing long neck PVC SWR Type-B P trap size 32mm bore, 300 mm long for wash basins with inlet and outlet including nacessary packing, union and cap and fixed complete all as specified and as directed by Engineer-in-charge. |
| 55 | Supply and fixing in repair stainless steel, Chromium plated, decorative type, soap dish holder of approximate size 160mm x 160mm x 90 mm fixed to wall with rubber plugs complete all as specified and as directed by Engineer-in-Charge. |
| 56 | Supply & fixing in repair Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets,connecting union overall size 915mmx460mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fixing PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and as directed by Engineer-in-charge . |
| 58 | Supply & fixing in repair decorative Curtain rod stainless steel with fixing brackets, stops, rollers etc fancy type in repairs, complete all as specified and as directed by Engineer-in- charge. |
| 59 | Supply & fixing in repair brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fixing in repairs 450mm x 600mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame alround made of PVC channel, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and Fixing 110 mm bore of pipe PVC (SWR) type B pipes single socket 6 Kg/Sq cm in any length with Stack clamps made out of 50mm by 5 mm flat iron and 16mm dia round iron as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD-917 sheet sheet 1/1 of stays, including bolts and nuts and securing ends of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge. including Taking down old AC eaves gutters and rainwater pipes ( of any size and pattern), including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 62 | Supply and fixing 75 mm bore of pipe PVC (SWR) pipes type - A single socket in any length with rubber rung joint fixed to walls with MS clamps of F1 25x3mm or in trenches including Dismantling and discconecting of existing CI/PVC soil vent pipe 75 mm bore fixed to wall, laid in trenches incl all fittings & accessories complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply and Fixing 110 mm bore of pipe PVC (SWR) pipe type A single socketed in any length with rubber ring joint fixed to walls with projected galvanised MS clamps as specified, and also repair to blow holes / spouts and mouth of pipe for leak proof purpose including Taking down old AC eaves gutters and rainwater pipes ( of any size and pattern), including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 64 | Supply and fixing 110 mm bore of pipe PVC (SWR) pipes type - A single socket in anyt length with rubber rung joint laid in trenches or in floors and walls including Dismantling and discconecting of existing CI/PVC soil vent pipe 75 mm bore fixed to wall, laid in trenches incl all fittings & accessories complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply and fixing 110 mm bore of PVC (SWR) type-A bends of any radius, shoe, branch pieces, single (single Y) equal or unequal, tee, vent, cowl, etc fixed to PVC pipes complete all as specified and directed |
| 66 | Supply and fixing 75 mm bore of PVC (SWR) type-A bends of any radius, shoe, branch pieces, single (single Y) equal or unequal, tee, vent, cowl, etc fixed to PVC pipes complete all as specified and directed |
| 67 | Supply and fixing in repair 110 mm PVC (SWR) 'P' or 'S' trap screwed to PVC pipe complete all as specified and directed |
| 68 | Suppying and laying of CPVC pipes of 16mm outer dia, SDR 11 & Plain CPVC SDR 11 fitting in trenches and fixed to walls & ceiling or laid in floors, cutting chases in brick walls girth exc 10 cm but not exc 20 cm wide for concealed water tubing etc and making good in CM 1:3 or PCC 1:2:4 as required including taking sown or up 15 mm bore steel tubing and connection complete all as specified and directed |
| 69 | Suppying and laying of CPVC pipes of 20mm outer dia, SDR 11 & Plain CPVC SDR 11 fitting in trenches and fixed to walls & ceiling or laid in floors, cutting chases in brick walls girth exc 10 cm but not exc 20 cm wide for concealed water tubing etc and making good in CM 1:3 or PCC 1:2:4 as required including taking sown or up 20 mm bore steel tubing and connection complete all as specified and directed |
| 70 | Supply and fixing in repair 100/75 mm dia PVC (SWR) floor trap type B , plain with grating including jointing with solvent cement, 75mm, 100mm dia with grating inlcuding jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply and fixing in replacement three layers 1000 litre HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and as directed by Engineer-in-charge. |
| 72 | Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 73 | Material and labour for RCC (1:2:4) type B1 using 20mm aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge. |
| 74 | Material and labour for Formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) on rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge. |
| 75 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation etc or for shafts , wells, cesspits, manholes , septic tank, for laying of cables , laying of pipes not exceeding 10 Sqm on plan and not exc 1.5 meter depth and getting out in soft/loose soil etc complete all as specified and as directed by Engineer-in- charge. |
| 76 | Returning filling in any type of soil, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm in each layer, complete all as specified and as directed by Engineer-in- charge. |
| 77 | Removing excavated material as in all kind of Soils not exceeding 2.0 Km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in- charge. |
| 78 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete)of any dia set in cement laid in trenches incl all fittings & accessorises complete all as specified and as directed by Engineer-in- charge. |
| 79 | Supply and laying DWCPE (SN 8) drain pipes 200 mm nominal dia as per IS-16098 (Part-II), laid in trenches on bed including all accessories/ fittings/ jointed ring, jointing and testing complete all as specified and as directed by Engineer-in- charge.Note:- Excavation , earth work, bedding and pedestal / anchorage if required shall be measured and paid separately under appropriate item of BOQ/ Sch 'A' |
| 80 | Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed of SGSW drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm. |
| 81 | Material and Labour for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for Internal dia of pipe in 150 mm complete all as specified and as directed by Engineer-in-charge. |
| 82 | Material & labour for Cement Concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for foundations, fillings & mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 83 | Material & Labour for 60 mm thickness, M-35 Grade ,of any shape and size , Factory made Machine pressed precast concrete interlocking paver block with grey cement and no pigment confirming to IS 15658-2006 of complete all as specified and directed by Engineer-in-charge. |
| 84 | Material and Labour for 75 mm thick PCC 1:3:6 , Type C-2 using 40 mm graded stone aggregate as in plinth protection, finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in- charge. |
| 85 | Demolition of cement concrete reinforced of any discription and in any position, including reinforcement cut as required to facilitate and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge. Note:The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. |
| 86 | Material and labour for suspended false ceiling consisting of suitable anodised alumiumum sections of 'Tee' of size not lesss than 22.50 x 22.5 x 0.5 mm Angle of size 22.5 x 22.5 x 0.5 mm & FI as per std engineering practices with 'E' board ceiling boards 4 mm thick in grid of 605 x 605 mm including cutting holes and making good holes for main joist, suspending with 6 mm dia GI wire to roof trusses, purling & rafters etc all as specified and directed. |
| 87 | Supply and fixing for Pre -Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm Thickness of any colour having Tensile strength of 550 MPA as in roof covering fixed with 'L' type or 'J' type or cranked hook bolts all as specified and directed by Engineer-in-Charge. |
| 88 | Supply and fixing for Pre -Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm Thickness of any colour having Tensile strength of 550 MPA as in roof covering fixed with 'L' type or 'J' type or cranked hook bolts all as specified and directed by Engineer-in-Charge. |
| 89 | Material and labour water proofing treatment to parapet wall with PU Elastoseal primer with epoxy primer to seal the pores and enhance the adhesive of the coating, supplying and applying single componet waterproofing liquid membrane based on pure elastomeric polyurethaance resin cold applied of spray/brush applied membrane with an elongation of 650% +- 50 and tensile strnength not less than 2 Mpa, crack brdging abilityy noyt less than 2 mm. No leakage up to five bars of water pressure sore hardness > 50 shore. The minimum thickness to be applied shall be 1.5 mm (overall) in two layers (each layer 750 micron) or as per manufacturer's instructions so as to achieve thickness not less than 1.5 mm |
| 90 | Dismantling water tanks of capacity not exceeding 500 ltr each and removing to store |
| 91 | Dismantling water tanks of capacity exceeding 500 ltr but not exceeding 1000 ltr each and removing to store |
| 92 | Supply and fixing in replacement three layers 500 litre HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and as directed by Engineer-in-charge. |
| 93 | Supply and Fixing in repair Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge. |
| 94 | Material and labour for demolition of concrete as in Roofs, floors (other than ground floors), beams, straircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in- charge. |
| 95 | Material and labour for mild steel TMT bars 6mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 96 | Carefully chipping, removing existing loose / damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer / chipper without damaging the existying sound concrete and exposing old reinforcement upto 10 mm -20 mm beyond corroded reinforcement bars using electricity operated diamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and cleaning all existing reinforcement bars then by air blower, making the edges straight and even and cleaning it by wire brush and Cleaning all exiting reinforcement bars then by air blower, applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs, Providing and application of Zinc rich epoxy anti-corrosive protective coating for reiforcment bars as corrosion protection system in 2 coats to the entire circumference surface of bars, Apply SPR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar, Rebuilding the section of structural damaged RCC/PCC repair to spalling concrete to its original size and shape in layers on 10 mm average thickness in 1st layer then subsequent layers as per requirement by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >=5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and as directed by Engineer-in-charge, Make : Sika- Monotop 122 F/R Forsoc - Renderoc S2/Pidilite Dr Fixit Polymer Mortar HB or equivalent make approved by Engineer-in-charge complete all as specified and as directed by Engineer-in-charge |
| 97 | Material & Labour for complete removal of existing treatment of any description on old wall surafce of any description of surface by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and wall care putty (2mm thick) in two layers ( each layer 1mm thick ) over new surfaces.complete all as specified and directed by the Engineer-in-Charge.Note : Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 98 | Material and Labour for preparation of new surfaces by mechanized sander having suction vacuum bag using smart periodical methodology complete all as specified and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and wall care putty (2mm thick) in two layers ( each layer 1mm thick ) complete all as specified and directed.Note : Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 99 | Complete removal of existing treatment on Old Internal wall surfaces of any description, preparation of surface by Mechanised sander having suction vacuum Bag using Smart periodical methodology, complete all as specified and applying the following :-(a) Material and Labour for wall care putty (2mm thick) in two layers (each layer 1mm thick ) on wall surface and smoothening the surface with sand papers / Mechanised sanding etc preparatory to paint as directed complete all as specified(b) Material and Labour for two coat of acrylic emulsion distemper of approved tint over a coat of acrylic primer on old prepared surface by using Airless spray / Roller complete all as specified.Note:- 1.Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.2. Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 100 | Preparation of new plastered Internal wall surface complete all as specified complete all as specified and applying the following:-(a) Material and Labour wall care putty (2mm thick) in two layers (each layer 1mm thick ) on wall surface and smoothening the surface with sand papers / Mechanised sanding etc prepatory to paint as directed complete all as specified.(b) Material and Labour two coat of acrylic emulsion distemper over a coat of chalk whitening priming by using Airless spray/Roller complete all as specified.Note:- 1.Contractor may use manual scraping tools for complete removal and surface preparation with prior approval of Engr-in-Charge in case of using of Mechanical equipment are not possible.2. Before applying painting (Interior Acrylylic emulsion & Exterior emulsion) in bldgs a sample patch of size 1 mtr x 1 mtr to be done for approval of GE. Painting should be done by using painting roller, mechanically method and as per manufacturer's instructions cost for the same for scaffolding for plastering & painting etc is included in the rates quoted by the contractor. |
| 101 | Material and labour for applying three coats of white wash on newly plastered or unplastered ceiling surfaces including preparation of surfaces, complete all as specified and as directed by Engineer-in- charge. |
| 102 | Material and labour for old surafaces of ceiling and applying one coat of white wash complete all as specified and as directed by Engineer-in- charge. |
| 103 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem , sheet switches, ceiling rose, pendent holder , sockets, fan regulator , bell push, Electronic bell , sunken box except concealed conduit etc. complete all as specified and directed by Engineer-in-charge. Notes:(i) The weight of aluminium scrap , copper scrap and Iron scrap shall be ascertained by BOO as ordered by GE and same duly countersinged by GE shall be enclosed with final Bill. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item no. 112.00 to 116.00 of BoQ. |
| 104 | Material and labour point wiring for one light / fan point controlled by 6 amps one way modular switch switch with 2.5 Sqmm PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including concealed PVC conduit 20 mm dia heavy duty ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush with other switch or independent including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-charge. (Note:- Switches, sockets etc shall be measured and paid for separately under items of Schedule). |
| 105 | One socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and as directed by Engineer-in- charge. |
| 106 | One socket outlet three pin, 6 Amp, on the Independent, with 2.5 Sq. (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, complete all as specified and as directed by Engineer-in- charge. |
| 107 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and as directed by Engineer-in- charge. |
| 108 | One socket outlet three pin, 5/15 Amp, independent, with 4.0 Sq. (nominal area) cable & 4.0 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and as directed by Engineer-in- charge. |
| 109 | Note For Serial Item No 104.00 to 104.04.001. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'2. GI boxes/ Modular flush box shall be fixed flush in position with cement mortar (1:4) complete all as directed. |
| 110 | Supply & Fixing Modular switch one way 6 Amp, one module, 250 volts, one way, complete all as specified and as directed by Engineer-in-charge. |
| 111 | Supply & Fixing Modular switch one way 16 Amp, one module, 250 volts, one way, complete all as specified and as directed by Engineer-in-charge. |
| 112 | Supply & Fixing modular type Socket outlet , multipurpose, 2/3 pin, 6 Amp, two module 250 volts, ISI Marked complete all as specified and as directed by Engineer-in-charge.. |
| 113 | Supply and fixing modular socket outlet multipurpose, 2/3 pin, 6/16 Amps, two module, 250 volts, complete all as specified and as directed by Engineer-in-charge. |
| 114 | Supply and fixing fan regulator, modular type, 5 step, high speed, two module complete all as specified and as directed by Engineer-in-charge. |
| 115 | Supply & fixing ceiling rose surface type PVC polycarbonate isolated body two to three terminal , tp line series 20x50mm, 6 amps three terminal complete all as specified and as directed by Engineer-in- charge. |
| 116 | Supply and fixing in replacement Single Pole and Neutral enclosure with a two pin and earth plug and socket complete with and including one MCB single pole of capacity 20 Amps,'C' curve,10KA , 240 volts complete all as specified and directed by Engineer-in-Charge.Note: The rate of one MCB single pole of capacity 20 Amps,'C' curve, 10KA, 240 volts is included in this item and nothing shall be paid extra on this account. |
| 117 | Supply and Fixing wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 25watt, 6500K, efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver ,complete with and including connection with copper cable of suitable size from ceiling rose to fitting complete all as manufacturer's instructions ,complete as specified and as directed by Engineer-in-charge. |
| 118 | Supply and fixing LED batten fitting 1X10 watt, 6500K, 2 ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environment friendly, energy efficient complete with all light connection all as specified and directed |
| 119 | Supply and Fixing LED Panel Light fitting recessed mounted,square shaped of size 595mm x 595mm x 65mm , 36 (±10%) watt, efficacy not less than 90 lumen/watt , extruded Aluminium/polycarbonate, PC diffusor and inbuilt driver complete as per manufacturer's instructions with and including connection with flexible twin core copper cable of size 23/.00076 from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge. |
| 120 | Supply and Fixing LED Street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection with and including bracket made out with and including 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 25mm x 3 mm MS flat iron with suitable bolt and nuts complete with and including connection with copper cable of suitable size from ceiling rose to fitting complete all as manufacturer's instructions ,as specified and as directed by Engineer-in-charge. Note: The rate of 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 25mm x 3 mm MS flat iron with suitable bolt and nuts is included in this item and nothing shall be paid extra on this account. |
| 121 | Supply and Fixing lamp holder PVC/ polycarbonate type with back plate suitable for batten fitting with self ballast LED retrofit Lamp with PVC body and PC Diffuser 9 watt complete all as specified and as directed by Engineer-in- charge. |
| 122 | Supply and fixing LED 5W Lamp base B-22 complete all as specified and as directed by Engineer-in- charge. |
| 123 | Material and labour in replacement Sub main wiring complete with two single core 6 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH with and including single core 6 sqmm,1100 volts grade, PVC insulated, multi stranded copper conductor cable FRLSH for earth wire in existing PVC concealed conduit (Colour code phase-Red, Neutral-black and Earth as Green) complete all as specified and directed by Engineer-in-charge. Notes:-(a) Three single core 6 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade shall be measured as one length. |
| 124 | Supply and Fixing Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,IP-43 protection, double door, powder coated DB SPN 12 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ. |
| 125 | Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB TPN 4 way, 415 V AC with 63 Amps rated bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ. |
| 126 | Supply & fixing in MCB single pole 6-32 Amp suitable for 240 volt, 10 KA complete including taking down old unserviceable MCB SP complete all as specified and as directed directed by Engineer-in- charge. |
| 127 | Supply & fixing in MCB single pole 40-63 Amp suitable for 240 volt, 10 KA complete including taking down old unserviceable MCB SP complete all as specified and as directed directed by Engineer-in- charge. |
| 128 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 129 | Supply & Fixing Ceiling fan of 1200mm sweep complete with blades, down rods, including electronic regulator (modular type, 120w, 2 module) and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement , with and including serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete complete all as specified and as directed by Engineer-in-charge. |
| 130 | Supplying, laying, jointing & testing, in replacment underground XLPE insulated screen PVC bedded, GI steel strip or wire armoured heavy duty LT electric power cable with aluminium conductor, 1100 volts grade, cross sectional area 35 sqmm 4 core complete all as specified and as directed by Engineer-in-charge. |
| 131 | Supplying, laying, jointing & testing, in replacment underground XLPE insulated screen PVC bedded, GI steel strip or wire armoured heavy duty LT electric power cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core complete all as specified and as directed by Engineer-in-charge. |
| 132 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose) |
| 133 | Supply and laying un-reinforced precast concrete cable cover, class LV type-I, flat size 250 mm x 150 mm x 40 mm for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |