| 1 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed. |
| 2 | Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 3 | Dismantling floor, hearth and wall tiling including cement mortar bedding (but excluding backing), removing rubbish off the premises complete all as directed. |
| 4 | Demolition of brick or stone masonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick ( Below or above ground) complete all as specified and directed. |
| 6 | S&F 0.63 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. |
| 7 | S&F Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed. |
| 8 | S &F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour as approved by AGE(I) having tensile strength of 550 Mpa as in ridges,valley complete all as specified and as directed. |
| 9 | M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work and including dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed. |
| 10 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 11 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed. |
| 12 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as \\"Supply only\\". |
| 13 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Supply only integral water proofing compound complete all as specified and as directed. |
| 15 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 16 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 17 | S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid including taking down old one complete all as specified and as directed. |
| 18 | S&F for 4mm thick vaneered decorative plywood, grade 1 (with BWR resin) with decorative face on one side fixed with nails to timber frame work including taking out old plywood of any description complete all as specified and as directed. |
| 19 | M & L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layers in 15mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 20 | M & L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layers in 10mm thick screed bed in cement motar 1:3, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed. |
| 21 | M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 22 | Taking down chowkats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm complete all as specified and directed. |
| 23 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from frame) complete all as specified and directed. |
| 24 | S&F Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 25 | S&F three track Anodised aluminium sliding window with approved make of following extruded section of anodised glazed shutter as per standard engineering practices including all other accessories complete like 5mm thick glass panes, rubber beading etc complete all as specified and as directed. Aluminium section A series are as under:-(i) Shutter bottom& top :-37.5x15x1.3mm thick(ii) Shutter interlock :- 37.5x23x1.3mm thick(iii) Shutter side(Handle):- 37.5x23x1.3mm Thick(iv) Frame bottom 75x26x1mm thick(v) frame top and sides:175x26x1mm thick. |
| 26 | S & F Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necssary joining cleats,glazing clips,ruber neoprene packing, handle 2 Nos in Each door, hinges, anodised aluminium snap bidding, screw etc. complete all as specified and directed. |
| 27 | S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around theopening, all complete as per requirement and direction of Engineerin-charge. |
| 28 | S & F 5.5mm thick sheet glass, ordinary quality and square exc 0.5 sqm in each pane complete all as specified and as directed. |
| 29 | S&F 2nd class hardwood plain, solid, straight chowkatsand frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned atjoints complete all as specified and as directed. |
| 30 | S&F 30mm thick flush shutter, Flush shutters, solid coreconstruction, with block board core and plywood face panels, commercial type on both sides face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed. |
| 31 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 32 | S & F 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed. |
| 33 | S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 34 | S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 35 | S&F in repair 19/20mm harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed. |
| 36 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to woodtrusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 37 | S&F aluminium (diacast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed. |
| 38 | S & F floor door stopper of aluminium alloy body and tongue, overall length of cover plate 140 mm anodised with hard drawn steel spring, fixed in floors complete all as specified and as directed. |
| 39 | S & F 500 litres capacity rotational moulded(Three Layer) polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed including dismantling of old tank of any description complete all as specified and as directed. |
| 40 | S&F in repairs, 20mm bore, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for union complete all as specified and directed. |
| 41 | M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 42 | M&L for preparation of old painted steel surfaces of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paints complete all as specified and as directed. |
| 43 | M&L for preparation of old wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel complete all as specified and as directed. |
| 44 | M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed. |
| 45 | M&L for complete removal of existing treatment of wall and preparation of treated surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed. |
| 46 | M&L for complete removal of existing treatment of wall and preparation of treated and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 47 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 48 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed. |
| 49 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends, complete all as specified and directed. |
| 50 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 51 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FR-LSH cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed. |
| 52 | All as per item serial No 51 here-in-before but for One 3 pin 5 Amp socket combination on independent board with other switches. |
| 53 | All as per item serial No 51 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board. |
| 54 | S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed. |
| 55 | S & F switch socket combination outlet 3 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed. |
| 56 | S & F switch socket combination, multipurpose, 2 in 1, 3 pin, 15 & 16 Amp flush type complete all as specified and as directed. |
| 57 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 58 | S & F in repairs LED tube fittings1x20W, 220V, with necessary fittings and fixtures including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as directed. |
| 59 | S & F in repairsLED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. |
| 60 | S & F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. |
| 61 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amp rating copper bus bar complete all as specified and as directed. |
| 62 | S&F MCBs, SPN/DP 40 to 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 63 | S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 64 | M&L for house service GI bracket(Hook type) made out of 40 mm bore medium grade GI Pipe of length 3m and one No 90 degree bend fixing with clamps, nuts and bolts, MS hooks,stay etc, including dismantling old one complete all as specified and as directed. |
| 65 | S&F 1100 volts grade heavy duty flat cable of size 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 66 | M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I and including taking down of old ones, complete all as specified and directed. Please Enable Macros to View BoQ information |