| 1 | Dismantling timber scantlings 40 sqcm and over in section, in any position of framed work complete all as specified and directed. |
| 2 | Dismantaling of Asbestos cement/GI (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 4 | S&F rolled mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410W Grade E 250 complete all as specified and directed. |
| 5 | M & L for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof Ridge, fixed with self tapping screws complete all as specified and directed. |
| 6 | M & L for Pre-painted galvalume aluminium zinc coating GI based Corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof Ridge, fixed with self tapping screws complete all as specified and directed. |
| 7 | Dismantling wall and ceiling board (fiber, pulp, PVC, insulation etc) or insulation boards / slabs / blankets, any thickness including cover fillets complete all as specified and directed. |
| 8 | S & F for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre, size of grid 605mm x 605mm complete all as specified and directed. |
| 9 | S & F for hangers 6 mm dia GI (upto 1200mm length adjusting level fixed to roof/slabs by means of ceiling cleats made out of GI flat 40X30 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 10 | M & L for 6 mm thick Non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / Aluminium framework with screws complete all as specified and directed. Make- Armstrong, Hunterdouglas etc |
| 11 | Dismantling of floor, hearth or walls tiles including cement mortar bedding but not backing and rubbish off permises complete all as specified and directed. |
| 12 | M&L for Mirror polishing on existing marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed. |
| 13 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm & not exceeding 0.38 sqm in floors etc over and including 15mm thick screed bed in CM 1:6 set & jointed in neat cement slurry and pointed with white cement mixed with pigments to match the shade of tiles complete all as specified and directed. |
| 14 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.18 sqm & not exceeding 0.38 Sqm , in vertical surface such as skirtings, dados etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match with shade of tiles over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed. |
| 15 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm & not exceeding 0.18 sqm in floors etc over and including 15mm thick screed bed in CM 1:6 set & jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles complete all as specified and directed. |
| 16 | M&L for glazed ceramics coloured tiles of size 450x300x7mm thick in vertical surfaces such as skirting/dados/wall, etc over and including 10mm thick rendering in cmeent mortar (1:4) set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tiles complete all as specified and directed. |
| 17 | M&L 25 mm thick plain cement concrete (1:2:4), type B-0, using 12.50 mm graded stone aggregate as in floors including finishing the surface rough & even for receiving kota/tiles complete all as specified and directed. |
| 18 | Demolition of brick work built in cement mortar including all quions, arches, pillars, etc complete all as specified and directed. |
| 19 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed. |
| 20 | Taking down cement plaster on wall/ceiling/roof etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 21 | M&L 15 mm thick rendering on fair faces of brick /concrete surfaces in CM (1:6), finished even and smooth (without using extra cement ) complete all as specified and directed. |
| 22 | M&L for rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces, second layer (finishing coat) mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement or as per manufacturer's instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. Note : Liquid WPC will be measured and paid separately. |
| 23 | Supply only water proofing compound (liquid), ISI marked. |
| 24 | Taking down chowkats or frame with shutters of any description (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed. |
| 25 | All as per above item No 24 but exc 1.5 Sqm but n.exc. 4 Sqm each. |
| 26 | Taking down shutter of any description exc 1 sqm and n exc 2 sq. m each and removing to store. |
| 27 | S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed. |
| 28 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 29 | S&F 100 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified. |
| 30 | S&F floor door stopper 140 mm overall length of cover plate of aluminium alloy body and tongue, anodised. With hard drawn spring, fixed in floor complete all as specified and directed. |
| 31 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 32 | S&F in repair Door closer hydraulically regulated cast iron body, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 33 | Dismantling water tanks and removing to store of capacity exc 500 and n exc 1000 ltrs complete all as specified and directed. |
| 34 | S&F Rotational moulded polyethylene water storage tanks in white colour tripple layer (cylindrical vertical with closed top) hoisted and fixed in position of 1000 Ltr capacity complete all as specified and directed. |
| 35 | S&F 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball srewed for iron pipe and fixed (minium weight 20mm-210) gms complete all as specified and directed. |
| 36 | M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 37 | M&L Preparing old steel surfaces exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 38 | M&L for applying 2mm thick Birla / JK Putty in two layers on old wall surfaces including complete removal of existing wall finish of any type with wire brush, brooming, dusting and finally washing with water to clean the surface absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper complete. |
| 39 | M&L preparation of new plastered or unplastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 40 | M & L for preparation of newly plastered surfaces of wall & concrete and applying 2 mm thick wall care putty including preparation complete all as specified and directed. |
| 41 | M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 42 | M&L preparation of new plastered surfaces of wall and applying two coats of weather coat paint (apex) over a coat of primer complete all as specified and directed. |
| 43 | M&L for two coats of weather coat paint (apex) over a coat of primer on wall including preparation of old plastered surfaces complete all as specified and as directed. |
| 44 | S&F in repair plastic water closet seat cover, Cream / white colour, closed pattern with flat bottom and cover and mild steel chromium plated aluminium hinging device for pedestral pattern WC. |
| 45 | S & F in repair aluminium door shutter with following specification:-(a) chowkhat frame of size 63.50x38.10x1.95mm thick weight @ 1.092Kg/RM.(b) Style/Vertical member of size 47.62 x 44.45 x 2.02 mm thick weight @ 1.052Kg/RM(c) Top member of size 47.62 x 44.45 x 2.02 mm thick weight @ 0.974(d) Bottem member of size [email protected]/m(e) Top panel with 5.00 mm thick tinted glass fixing with rubber gasket.(f) Bottom panel with 5 to 6 mm thick Alumnium composite panel thick with clips(g) 100 mm dia round handle disc type -02 nos & Alu tower bolt 200mm - 01 No, Hinges 04 Nos each shutter.(h) Aluminum and PVC beading as per requirment as in fixing for ACP shhet & Glass, jointing cleat including locking arrangement. etc. |
| 46 | S & F in repair aluminium window sliding shutter three track with following specification:-(a) chowkhat frame bottem member of size 92x31.75x1.50mm @ 1.248Kg/RM.(b) chowkhat frame Top & side members sides and member of size 92x31.75x1.50mm @ 1.060Kg/RM.(c) Shutter sides members of size [email protected]/RM(d) Partialy 0.63 mm dia stainless steel wire netting mosquito proof with fixing arrangment.(e) Partialy 5.00 mm thick tinted glass fixing with rubber gasket.(f) Aluminum and PVC beading as per requirment as in fixing for paticle board & Glass, jointing cleat including locking arrangement. etc |
| 47 | M & L for plain cement concrete 1:3:6 type C-0 (using 12.50 mm graded stone aggregate), as in hold fast and similar workd including necessary form work as required complete all as specified and directed. |
| 48 | Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing surfaces complete all as specified and directed. |
| 49 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one light/fan/bell/buzzer / exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 50 | Same as item No. 49 here-in-before but one 3 pin, 5amp socket out let on independent board complete all as specified and directed. |
| 51 | Same as item No. 49 here-in before but 3pin ,5amp socket out let on the same board with other switch complete all as specified and directed. |
| 52 | Same as item No 49 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm. |
| 53 | M&L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 4.0 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring including concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 4 Sqmm FR type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 54 | M&L sub main wiring with two single core PVC insulated & unsheathed cable 6.0 Sqmm (nominal area) FRLS type having multi-stranded copper conductor drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring with and including 6.0 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as earth wire connected to common earth as per IS & cutting chasing for conduit & sinking for boxes & making good to walls disturbed surface & applying finishes to match existing surface complete including taking down of exsting sub main wiring complete all as specified and directed.NOTE : Two runs of 6 Sqmm and one run of 6.0 Sqmm cable and PVC conduit shall be measured as a one unit length. |
| 55 | M&L for sub main wiring with PVC insulated 1100V grade FRLS single core multi stranded copper conductor cable of size 2x4 sqmm + 1x 4 Sqmm as earth continuity cable passing through and including 25/20mm dia PVC concealed conduit all as specified and directed. Note - Two runs of 4sqmm including one run of 4 sqmm including PVC conduit shall be measured as unit length. |
| 56 | S & F for switch piano, flush type, 5 amps, single pole , one way , 230 volt complete all as specified and directed. |
| 57 | S & F for 2/3 pin, 5 Amp/ 6 Amp , socket outlet, flush type, 2 in 1 complete all as specified and directed. |
| 58 | S&F switch socket combination 2 in 1, 6 pin 16Amps multipurpose type 240 volts complete all as specified and directed. |
| 59 | S&F ceiling rose single phase , PVC poly carbonate, insulated body three terminals ISI marked complete all as specified and directed. |
| 60 | S&F sheet metal enclosure for 4 way TPN DB double door 415 Volt with 200 Amp rated bus bar complete with suitable for 1 x 100Amp TPN as incomer and MCB SPN as outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs complete all as specified and directed. |
| 61 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity 63 Amp in the DB with connection testing and commissioning complete all as specified and directed. |
| 62 | S& F for sheet metal enclousre factory made for MCB DB's SPN, 12 way, double door, 240 Volts with 200 Amp rated bus bars including taking down existing unserviceable MCB DB complete all as specified and directed. |
| 63 | S&F MCB SP 240 Volt 6 TO 40 Amp ISI marked conforming to 'B\\" curve, breaking capacity 10 KA complete all as specified and directed. |
| 64 | S&F MCB SPN 40-63 amp 30mA for earth leakage. Over load and short circuit protection ISI marked complete all as specified and directed. |
| 65 | Supply & fixing fan regulator, socket type compatible for BLDC fans ,single phase complete all as specified and directed. |
| 66 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type Extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser , 4 ft,2000lm,voltage protection range 140V -270 V,NW 4000K ,connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make : Philips /bajaj or eqivalent. |
| 67 | Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency warm type PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 68 | Supply, fixing and testing of ceiling fan 1200 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, BEE 5 star rating, ISI marked complete with down rod, canopy, blades, BLDC motor without remote, electronics fan regulator etcwith 5 year on site warranty and connecting up complete including complete connection from ceiling rose to fan including writing of MES Number with synthetic enamel paint and depositing old fan to MES store for further BER complete all as specified and directed. |
| 69 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep ,heavy duty with, blades, and frame and louvers complete all as specified. |
| 70 | S & F Building security/street LED light fitting 35 watt IP-65 protection pressure diecast alluminium body ,heat resistant glass ,including driver and making necessary electric connection with 2.5 sqmm twin core copper wire 1.5 long complete fixed in GI pipe fixed to pole complete all as specified and directed. |
| 71 | S & F Modular metal flush box 1/2 module |
| 72 | S & F Modular metal flush box 3 module |
| 73 | S & F Modular metal flush box 8 modules(Horizontal) |
| 74 | S & F modular white cover plate 1 module |
| 75 | S & F modular white cover plate 2 module |
| 76 | S & F modular white cover plate 3 module |
| 77 | S & F modular white cover plate 8 (Horizontal) modules |
| 78 | Supply & fixing switch modular flush type 6 amps, single pole, one way complete all as specified and directed. |
| 79 | Supply & fixing socket modular flush type suitable for 6 amp, 2/3 module combined 2 module complete all as specified and directed. |
| 80 | Supply & fixing switch modular flush type 16 amps, single pole, one way complete all as specified and directed. |
| 81 | Supply & fixing socket modular flush type suitable for 6/16 A, 2/3 pin combined 2 module complete all as specified and directed. |
| 82 | S& F for sheet metal enclousre factory made for MCB DB's SPN, 8 way, double door, 240 Volts with 200 Amp rated bus bars including taking down existing unserviceable MCB DB complete all as specified and directed. |
| 83 | Supply & fixing fan regulator, modular type, socket type compatible for BLDC fans ,single phase complete all as specified and directed. Please Enable Macros to View BoQ information |