| 1 | Remaining Work of Fire Station |
| 2 | Earth work in excavation in foundation, trenches etc. includingdressing of sides and ramming of bottoms, including getting out theexcavated material, refilling after laying pipe/ foundation anddisposal of surplus excavated material at a lead upto 50m suitablesite as per direction of Engineer for following depths, below naturalground / Road top level |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).below masonary |
| 4 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 5 | Random rubble dry stone Kharanja (soling) under floor. |
| 6 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).below flooring |
| 7 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work upto plinthlevel1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size |
| 8 | P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirtingand steps etc.in different sizes (thickness to be specified bymanufacture) with water absorption less than 0.08% and conformingto IS 15622 of approved make in all colour and shade, laid with 20mm thick CM 1 : 4 including grouting the joints with white cementand matching pigment etc complete.Size 600 mm X 600 mm |
| 9 | Providing and fixing 1st quality MAT & GLOSSY finished ceramictiles colour such as standard white, grey, ivory, fume, red brown,light green, light blue, and other light shades with water absorptionless than or equal to 0.08% confirming to IS : 13753 & IS : 15622 infloor, steps etc laid on bed on neat cement slurry finished with flushpointing in the white cement mixed with pigment to match the shadeof the tile complete (including the cost of cement mortar bed 1:4)Size 300mm x 450mm |
| 10 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 11 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 12 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge |
| 13 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 15 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 16 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting,propping etc. and removal of form forSuspended floors, roofs, landings, balconies and access platform |
| 18 | Providing and laying in position specified grade of reinforced cementconcrete excluding the cost of centring, shuttering, finishing andreinforcement - All work upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 19 | Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets,columns, pillars, piers, abutments, posts and struts etc. upto twostories excluding cost of centring, shuttering, finishing andreinforcement :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size |
| 20 | Reinforced cement concrete work in beams, suspended floors,roofs having slope upto 15° landings, balconies, shelves, chajjas,lintels, bands, plain window sills, staircases and spiral stair casesupto two stories excluding the cost of centring, shuttering, finishingand reinforcementM-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3graded stone aggregate 20 mm nominal size) -As per design mix) |
| 21 | Reinforcement for R.C.C. work at all levels including straightening,cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars. |
| 22 | Cement plastering including T&P, scaffolding, material and completelabour, including cost of water, curing, racking of joints etc. with 12mm cement plaster of mix |
| 23 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) |
| 24 | Providing and fixing factory made Pre-laminated particle board flatpressed three layer or graded wood particle board with one sidedecorative finish and other side balancing lamination conforming toIS: 12823 Grade l Type ll, of approved design, and edges sealedwith water resistant paint and lipped with aluminium 'U' type edgebeading all-round the shutter, including fixing with angle cleat, gripstrip, cadmium plated steel screws including fixing of aluminiumhinges 100x63x4 mm etc. complete as per architectural drawing anddirection of Engineer-in-Charge (Cost of 'U' beading and hinges willbe paid for separately).25 mm thick |
| 25 | Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with PVC/ neoprene gasket etc. completeas per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basicitem)With float glass panes of 5.50 mm thickness |
| 26 | Providing and fixing double action hydraulic floor spring of approvedbrand and manufacture IS : 6315 marked, for doors including cost ofcutting floors as required, embedding in floors and cover plates withbrass pivot and single piece M.S. sheet outer box with slide plateetc. complete as per the direction of Engineer-in-charge. |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases andmaking good the same including testing of joints complete as perdirection of Engineer in-charge.Concealed work including cutting chases and making good thewalls etc.,20 mm nominal outer dia .Pipes |
| 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including allCPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00 m spacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and the cost of cutting chases andmaking good the same including testing of joints complete as perdirection of Engineer in-charge.Concealed work including cutting chases and making good thewalls etc.,25 mm nominal outer dia .Pipes. |
| 29 | Providing and fixing brass stop cock of approved quality |
| 30 | Constructing masonry Chamber 30x30x50 cm, inside with 75 classdesignation brick work in cement mortar 1:4 (1 cement : 4 coarsesand) for stop cock, with C. I. surface box 100x100 x75 mm (inside)with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 finesand:10 graded stone aggregate 40mm nominal size) and insideplastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mmthick finished with a floating coat of neat cement complete as perstandard design |
| 31 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked with cover and suitablelocking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support for tank |
| 32 | Providing and fixing C.P. brass long nose bib cock of approvedquality conforming to IS standards and weighing not less than 810gms.15 mm nominal bore |
| 33 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm drybrick honey comb shaft with bricks of class designation 75 and S.W.drain pipe 100 mm diameter, 1.8 m long complete as per standarddesign |
| 34 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good the walls and floors whereverrequired : |
| 35 | Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes andfittings |
| 36 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chainwith rubber plug, 40 mm C.P. brass waste complete, includingpainting the fittings and brackets, cutting and making good the wallswherever required :36.9.1 White glazed fire clay kitchen sink of size 600x450x250 mm |
| 37 | Providing and fixing P.V.C. low level flushing cistern with manuallycontrolled device (handle lever) conforming to IS : 7231, with allfittings and fixtures complete. |
| 38 | Providing and fixing white vitreous china squatting plate urinal withintegral rim longitudinal flush pipe |
| 39 | Providing and fixing mirror of superior glass (of approved quality)and of required shape and size with plastic moulded frame ofapproved make and shade with 6 mm thick hard board backing |
| 40 | Providing and fixing 12mm thick Pre-laminated particle board flatpressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminium doors,windows shutters and partition frames with C.P. brass / stainlesssteel screws etc. complete as per architectural drawings anddirections of engineer-in-charge |
| 41 | Providing & laying broken glazed titles on roof ( broken glazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30 Kg/Sqm. Of VG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge.back area |
| 42 | Providing and laying four courses water proofing treatment withbitumen felt over roofs consisting of first and third courses of blownbitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ 1.45Kg per square metre of area for each course, second course ofroofing felt type 3 grade-I (hessian based self finished bitumen felt)and fourth and final course of stone grit 6mm and down size or peasizedgravel spread at 6 cubic diameter per square metre includingpreparation of surface but excluding grading complete with :38.8.1 Bitumen felt (hessian base) type 3 grade I conforming to IS : 1322. |
| 43 | Providing & Fixing of IP-20 LED Recessed / Surface Mounted,Round / Sqaure SMD Mid Power LED Downlight with power coateddie-cast aluminum housing with UV Stabilized non yellowishMinimum lumen output 330 lm |
| 44 | Providing & Fixing of following size mounting grid plates with coverplates made from fire retardent UV established high-performanceengineering plastic suitable for all universal metal boxes for frontinstallation & removal direct fit type complete in all respect.All as perpre approved by Engineer in-charge. For additional technicalparameters16/18 Module |
| 45 | Providing & Fixing of following size mounting grid plates with coverplates made from fire retardent UV established high-performanceengineering plastic suitable for all universal metal boxes for frontinstallation & removal direct fit type complete in all respect.All as perpre approved by Engineer in-charge. For additional technicalparameters12 Module |
| 46 | Providing & Fixing of modular type switch/ bell push duly ISI marked(IS :3854) with CM/L no. printed and made out of unbreakable andfire retardant vergin UV Stabilized Polycarbonate with brassterminals and captive screws & silver alloy contact tip with IP-20rating ,minimum width of switch toggle( PUSH PART ) should notless then 20mm, including all as per pre approved by Engineer incharge,making connections, testing etc. as required. For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR10 A one way switch |
| 47 | Providing & Fixing of 400 mm Sweep BLDC technology Oscillatingtype Wall mounting / Pedestal type fans with Three speed, ON andOFF position, Double Wall bearing with front and back 120 or moreribs guard; Three no. blades, noise level should be <= 75 dB,including fixing with anchor bolts, making connection testing etc. asrequired. ( With Remote ) All as per pre approved by Engineer incharge.For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR |
| 48 | SITC of Single Stage, water cooled, High Speed (2880 RPM),Horizontal, Centrifugal, Openwell Submersible pumps set pre filledwith coolent water and fitted with mechanical seal - T/C Vs T/C,Thrust bearing shall be of carbon + S.S.The stator body of singlephase pump shall be of SS and rest of all shall be of cast iron. Allcasting parts should be cathod electro deposition (CED) coated andother construction material should be confirming to IS : 14220: 2018. The overall performance of pump shall confirm to BEE energyefficiency level of 3 star. Valid BEE certificate from OEM must besubmitted for the same. Motor should be IE2 class as per IEC60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011, includingmaking connection etc as required complete in all respect. OEMshall have submit NABL / CPRI / ERDA accrediated lab type testcertificate before execution. All as per pre approved by Engineer incharge.For additional technical parameters of products/ work ,refer Annexure \\"A\\" attached with this BSR0.5 HP, 1-Ø, (7 -15) Mtr, (130 - 72) LPM |
| 49 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper conductor 1.1 kV grade and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virginmaterial PVC conduit & it's ISI marked (IS:3419-1988) accessories,round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box withearth terminal, 10A Modular switch, Modular face plate with gridplate, 3 pin ceiling rose / Holder /3 way connector, screws, makingconnections, testing etc. as required. For specification of copperConductor, Phenolic Laminated sheet's & Electrical/ Wiringaccessories refer Chapter-53, 54 & 56 for additional technicalparameters of product / work refer Annexure 'A' attached with thisShort point (up to 3 mtr.) |
| 50 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper conductor 1.1 kV grade and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virginmaterial PVC conduit & it's ISI marked (IS:3419-1988) accessories,round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box withearth terminal, 10A Modular switch, Modular face plate with gridplate, 3 pin ceiling rose / Holder /3 way connector, screws, makingconnections, testing etc. as required. For specification of copperConductor, Phenolic Laminated sheet's & Electrical/ Wiringaccessories refer Chapter-53, 54 & 56 for additional technicalparameters of product / work refer Annexure 'A' attached with thisMedium point (up to 6 mtr.) |
| 51 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexiblecopper conductor 1.1 kV grade and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virginmaterial PVC conduit & it's ISI marked (IS:3419-1988) accessories,round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box withearth terminal, 10A Modular switch, Modular face plate with gridplate, 3 pin ceiling rose / Holder /3 way connector, screws, makingconnections, testing etc. as required. For specification of copperConductor, Phenolic Laminated sheet's & Electrical/ Wiringaccessories refer Chapter-53, 54 & 56 for additional technicalparameters of product / work refer Annexure 'A' attached with thisLong point (up to 10 mtr.) |
| 52 | Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fanConforming to all the performance requirements laid down in IS374:2019 including all amendments, as applicable ; & Carry BISlicensing (i.e. ISI marking) with down rod up to 80 cm with secondarysupport safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvcinsulated flexible copper conductor making connection testing etc.as required. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR |
| 53 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round ofsize 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100mm length extended on each side . All as per pre approved byEngineer in-charge. For additional technical parameters of product /work refer Annexure 'A' attached with this BSR |
| 54 | Providing & Fixing of Recessed/surface mounting heavy dutyEnclosure made out from Galvanized steel / CRCA sheet not lessthen 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3.powder painted complete with din rail making internal DBterminations with copper lugs, detachable gland plate, includingmaking connections, testing etc. as required.For additional technicalparameters of product / work refer Annexure 'A' attached with this |
| 55 | Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilizationcategory, 4KV impulse withstand voltage, true contact indication,Red colour dolly / lever shall have single mould covering overallpoles for operation , two position din rail mounting, minimum phasetermination capacity of 35sq.mm. IP 20 contact protection and fittedin existing distribution board / sheet including making connections,testing etc. as required. OEM shall have submit NABL / CPRI /ERDA accrediated lab type test reports & All as per pre approvedby Engineer in-charge.For additional technical parameters of product/ work refer Annexure 'A' attached with this BSR |
| 56 | Supplying and fixing of power plug point with Modular accessoriesas per PWD specification for electrical Works, on hot dippedgalvanized modular box of 1.2 mm thick with earthingterminal/connector on surface or in recessed with suitable size ofmodular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socketoutlet (IS:1293) making connection , testing , etc. as required. Forspecification of Wiring accessories refer Chapter-56 related item &For additional technical parameters of product / work refer Annexure'A' attached with this BSR |
| 57 | Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required |
| 58 | Providing, lowering, laying in trenches, aligning, fixing in position andjointing socketed rubber gasket type ISI marked uPVC pipes ofClass III (6 Kg/sqcm) suitable for potable water with rubber ringjoints (as per IS 4985-2000) of following outer dia with allaccessories (excluding specials) complete including all material,labour, hydraulic testing and commissioning as per TechnicalSpecifications and as per direction of Engineer.Note : E/w to be measured and paid separately110 mm dia |
| 59 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete |
| 60 | Finishing walls with Deluxe Multi surface paint system for interiorsand exteriors using Primer as per manufacturers specificationsTwo or more coats applied @ 1.25 ltr/10 sqm. over and includingone coat of Special primer applied @ 0.75 ltr / 10 sqm |
| 61 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters.80x1.25mm M.S. laths with 1.25 mm thick top cover. |
| 62 | Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 16.80 sqm in area |
| 63 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design |
| 64 | Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Please Enable Macros to View BoQ information |