| 1 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 2 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. |
| 3 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 4 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs beams columns lintels curved or straight including fitting fixing and stricking out after completion of works (upto roof of ground floor ) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 5 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 6 | Reinforcement(for reinforced cement concrete work) in all sorts of structures incl. distribution bars, stirrups, binders etc of rods incl. supply initial straightening and removal of loose rust (if necessary) cutting to requisite length, hook and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction. a) TOR STEEL FOR GROUND FLOOR |
| 7 | 125 mm thick brick work with (1:4) sand cement morter incl.scafolding, curing etc all complete with 1st class brick |
| 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or rougening of concrete surface, including throating, nosing and drip course where necessary (ground floor) |
| 9 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC |
| 10 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer |
| 11 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. |
| 12 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). |
| 13 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 14 | M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc.(length of straight not less than 230 mm) |
| 15 | Galvanised iron sheet ridging fitted with necessary bolts,screws, washers etc complete.(225mm end lapping) (B) 450 mm lapping each way(c) With 0.80 mm sheet |
| 16 | Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(i) 16 mm dia bolt (b) 450 mm long |
| 17 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.For Rain water |
| 18 | c) Bend 87.5 degree (ii) 110 mm. Dia. |
| 19 | d) Shoe (ii) 110 mm. Dia. |
| 20 | (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor(ii) Grill weighing above 16 Kg./sq.mtr and above |
| 21 | Painting with ready mixed red lead paint of approved make and brand :(a) One coat |
| 22 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :: (b) On steel or other metal surface : With other than high gloss -(iv) Two coats (with any shade except white)Area same as Sl No- 15 |
| 23 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaste board includingG.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mmrespectively and web 27 mm ) along with perimeter of ceiling with G.I.intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thickofsize51.50mmx 26mm fixed to the intermediate channels with the help of connectingclip and in the direction of perpendicular to the intermediate channel of 300 mmc/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section asabove by machine screws. The boards are to be joined and finished with jointingcompound, paper tape and application of top coat etc. as per the direction ofEngineer-in-charge. (The rate includes of cost of all materials including taxes,cost of accessories, fittings and fixtures, scaffolding and labour charges etc.complete)In ground floor |
| 24 | Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor): b) Two Coatsii) Solvent based interior grade Acrylic Primer |
| 25 | Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats) ii) Luxury Quality |
| 26 | Supplying and fixing 240/415 V MCB Isolator ondin rail of existing DBs and necessary connection.Seimens / DP / 25A |
| 27 | Supplying and fixing 240/415 V MCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connectionSeimens / 6-32A / SP |
| 28 | Supplying and fixing 240/415 V change over (MCBmodule) of on din rail of existing DBs/ enclosureand necessary connection.Havells / 25A / DP |
| 29 | Supplying and fixing MCB SS enclosure with IP-20/30protection, powder coated provision for two/four poleMCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting,connection & provision for earthing attachment2 Way |
| 30 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthingattachment.Seimens / 2+8 way [Enclosure (8GB32102RC10)] |
| 31 | Supply & Fixing EI danger board on wall(a) 15 cm x 10 cm (6\\"x4\\") |
| 32 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. |
| 33 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface] (a) Average run 5 mtr |
| 34 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface](a) On Board |
| 35 | (b) Average run 1.5 mtr |
| 36 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Soft Soil [0.6x0.6x3 m] |
| 37 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe |
| 38 | Supply of LED Batten Tube Light Havells / Crompton / Philips or Similar make. |
| 39 | Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. |
| 40 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 41 | 3. AIR-CIRCULATOR FAN (Wall Mounting Type)Supply & Delivery of 230 V, 50 Hz, single phase, 85 watts, 18\\" (450mm), speed 1325 rpm (minimum), Bracket Fan and class of insulation: B, 4 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body with metal back cover. Power Factor not less than 0.9 and minimum air delivery 110 cu.m/min (minimum), including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 42 | 7. LED Flood Light fixture Supplying, installation, Testing & Commissioning of Flood light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours(Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM80 tested) and necessary inter-connections with 1.5 sq mm FR, PVCinsulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below:7.1 System lumen efficacy ≥135 <135 lm/Watt7.1.1 50 Watt Please Enable Macros to View BoQ information |