| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) over areas (exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m,as directed by Engineer-in-charge. |
| 2 | All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 4 | Providing,Laying, spreading and compacting stone soling of specified sizes in uniform thickness, hand picking, and compacting excuding cost of stone complete job |
| 5 | Providing and laying in position specified grade of cement concrete excluding the cost of centering and , shuttering , All work up to plinth level 1:4:8 (1cement: 4 coarse sand : 8 graded stone aggregate Incld. Carriage |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thickbed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgrouted with fine sand, including necessary excavation, levelling & dressing& finishing the top smooth. |
| 7 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished40 mm thick with 20 mm nominal size stone aggregate |
| 8 | Providing and laying in position machine batched and machine mixed design mixM-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site oflaying but excluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportions as per IS: 9103to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer-in-charge. (Note :- Cementcontent considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately) All works upto plinth level. |
| 9 | Providing and laying in position machine batched and machine mixed design mixM-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site oflaying but excluding the cost of centering, shuttering, finishing andreinforcement, including admixtures in recommended proportions as per IS: 9103to accelerate, retard setting of concrete, improve workability without impairingstrength and durability as per direction of Engineer-in-charge. (Note :- Cementcontent considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately) All works upto plinth level. |
| 10 | centring and shuttering includingstrutting propping etc and removal of form work for |
| 11 | Foundations, footings, bases of columns etc. for mass concrete. |
| 12 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 13 | Suspended floors, roofs, landings, balconies and access platforms |
| 14 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 15 | Columns, pillars, piers, abutments, posts and struts |
| 16 | Stairs, (excluding landings) except spiral-staircases |
| 17 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class Kail wood |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws,excluding panelling which will be paid for separately, all complete as per direction of Engineer-in -charge including 4 mm thick float glass panes, necessary screws. Second class kail wood |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Second class Kail wood |
| 22 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge ofaverage width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws Second class kail wood |
| 23 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 24 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5sqm per liter per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant |
| 25 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete (125x65x2.12) |
| 26 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete (100x58x1.90) |
| 27 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :250x16mm |
| 28 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.150x10m(Door) |
| 29 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete.100x10m(windows) |
| 30 | Providing and fixing bright finished brass handles with screws etc. complete : 100mm |
| 31 | Providing and fixing bright finished brass handles with screws etc. complete : 125mm |
| 32 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diaMetre bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 33 | Providing and laying Vitrified tiles in floor in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS:15622, of approved brand & manufacturer, in all colours andshade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointingwith grey cement slurry @3.3 kg/sqm including grouting the joints with whitecement and matching pigments etc. The tiles must be cut with the zero chippingdiamond cutter only . Laying of tiles will be done with the notch trowel, plier,wedge, clips of required thickness, leveling system and rubber mallet for placingthe tiles gently and easily.Size of Tile 600 x 600 mm |
| 34 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm 300 mm thick AAC blocks in super structure above plinth levelup to floor V level with RCC band at sill level and lintel level with approvedblock laying polymer modified adhesive mortar all complete as per directionof Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 35 | 12 mm cement plaster of mix (1:6) |
| 36 | Structural steel work riveted,bolted or welded in built up sections, trusses andframed work, including eaves boarding and weather boarding complete. |
| 37 | Providing and fixing precoated galvanized iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as perIS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or asdesired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, omplete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 38 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumenwashers complete. |
| 39 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 40 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 41 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer) , of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 42 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge in skirting, risers of steps and dados over 12 mm thick bed of cementMortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingn with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement including king posts of required pattern as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.).\\"6.75kg/Rft |
| 44 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cisternwith manually controlled device (handle lever) conforming to IS : 7231, with allfittings and fixtures complete including cutting and making good the walls andfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 45 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32mm C.P. brass waste of standard pattern, including painting of fittings andbrackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps. |
| 46 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to woodencleats with C.P. brass screws and washers complete. |
| 47 | Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fittings arrangement of approvedquality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effectiveheight of 88 mm, weighing not less than 170 gms |
| 48 | Providing and fixing toilet paper holder C.P. brass |
| 49 | Providing and fixing health faucet with concealed fitting arrangement of approved quality and make. |
| 50 | Providing and fixing 15mm nominal bore C.P brass bib cock of approved quality confirming to IS:8931 |
| 51 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single holebasin mixer of approved quality and make, including painting of fittings andbrackets, cutting and making good the walls wherever required:- (a) WhiteVitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single holebasin mixer |
| 52 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & makeas approved by Engineer in charge.(a) 15 mm nominal dia |
| 53 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS:893115 mm nominal bore |
| 54 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms. |
| 55 | Providing and installation of PUF (Puf Insulated Tanks ) with insulation thickness of 50 mm and density 40 kg/cu.m. UV protected with 0.5'c Change in stored water after 6 hours in continous 50'c or contionously in -20'C with capacity of 1000 Ltrs of Approved Brand As per the directions of engineer incharge Complete Job including carriage upto side of work. |
| 56 | Providing and fixing PTMT grating of approved quality and colour.Circular type |
| 57 | Providing and fixing Floor Traps including all fittings required complete job |
| 58 | Providing and fixing soil, waste and vent pipes : Prince Type B 75 mm dia |
| 59 | Providing and fixing soil, waste and vent pipes : Prince Type B 100 mm dia |
| 60 | Providing and fixing soil, waste and vent pipes : Prince Type B 160 mm dia |
| 61 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing ofpipes & fittings with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making goodthe walls etc.,)s |
| 62 | 15 mm nominal outer dia pipe |
| 63 | 20 mm nominal outer dia pipe |
| 64 | 25 mm nominal outer dia pipe |
| 65 | 32 mm nominal outer dia pipe |
| 66 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 67 | 15mm dia nominal bore |
| 68 | 20mm dia nominal bore |
| 69 | 25mm dia nominal bore |
| 70 | 32mm dia nominal outer dia pipe |
| 71 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 72 | 15mm dia nominal bore |
| 73 | 20mm dia nominal bore |
| 74 | 25mm dia nominal bore |
| 75 | Supply installation testing and commissioning of 1.5 HP water pump for lifting of water |
| 76 | Supply installation testing and commissioning water heater (Gyzer) 25 liter capacity ISI marked . |
| 77 | Providing and fixing kitchen sink including making all connections excluding costof fittings.White glazed fire clay sink of size600x450x250mm |
| 78 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand)finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as perstandard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 79 | Supply and installation of High Quality self Regulating heat Tracer of specialized Heating solution for winter isination of water pipe line including all accessories complete including supply and installation of circuit control panels with RCBO MCB, THERMOSTAT ()-@DEGC power connector - two way - 6 sqm w.p splice connector ,w.p tee connector,end seal,mounting kit-w.p,jb,g pipe strap4\\"and adhesive tape roll (50mm x 20m)f.g adhesive tape of any approved brand as per the directions of engineer in charge complete job. |
| 80 | Supply and fixing of high quality 32 mm thick nitile insulation tube for water pipilines of approved brand 2\\" size rock wool of apparent dencity 128kg per cum on outer side of the nitrile tube of 50mm thickness including aluminium duct clading aluminium sheet guage thickness .46 mm to .71 mm of approved quality and finished as per direction of enginees incharge ( Nitrile Tube 32 mm > Rock wool 50mm > Aluminium duct clading .46mm - .71mm ) |
| 81 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia inclduing Tee, elbow junction Box, fan,box etc |
| 82 | Providing and fixing of radiant floor heating system including all fixtures complete job including all carriages upto the site of work. |
| 83 | SEPTIC TANK AND SOAKAGE PIT Earth work in excavation by mechanical means (Hydraulic excavator) over areas(exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil. |
| 84 | Random rubble masonry with hard stone laid dry in foundation, plinth &wallsLaid with bond stone |
| 85 | Dry stone pitching (any thickness) excluding cost of stones. On Horizontal |
| 86 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 gradedstone aggregate 20 mm nominal size derived from natural sources) |
| 87 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources) |
| 88 | centring and shuttering includingstrutting propping etc and removal of form work for |
| 89 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 90 | Suspended floors, roofs, landings, balconies and access platforms |
| 91 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level:Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 92 | Carriage of sand from source to side of work by mechnical transport 7km including loading unloading complete. |
| 93 | Carriage of crushed aggregate from source to side of work by mechnical transport 25km including loading unloading complete.. Please Enable Macros to View BoQ information |