| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 6 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 3 x 1.5 sq. mm |
| 9 | 3 x 2.5 sq. mm |
| 10 | 3 x 4 sq. mm |
| 11 | 6 x 6 sq. mm |
| 12 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 13 | 20 mm |
| 14 | 25 mm |
| 15 | 32 mm |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 17 | 5/6 A switch |
| 18 | 15/16 A switch |
| 19 | 3 pin 5/6 A socket outlet |
| 20 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 21 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 23 | 1 or 2 Module (75mmX75mm) |
| 24 | 3 Module (100mmX75mm) |
| 25 | 4 Module (125mmX75mm) |
| 26 | 6 Module (200mmX75mm) |
| 27 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 28 | 6 way , Double door |
| 29 | 8 way , Double door |
| 30 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 31 | 4 way (4 + 12), Double door |
| 32 | 12 way (4 + 36), Double door |
| 33 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Single pole |
| 35 | Double pole |
| 36 | Triple pole |
| 37 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 38 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 41 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 42 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 43 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 44 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 45 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 46 | 4 X 50 sq. mm (35mm) |
| 47 | Supplying and fixing of 16 Amps Modular Socket with Shutter, 3 Module including connection, etc., as required. on existing modular cover plate. Make:Legrand Myrius Equivalent |
| 48 | Supplying and fixing 100A, 16kA, 4 pole (Three pole and Neutral), 415 V, Moulded casing circuit breaker (MCCB) with thermal magnetic protection unit in the existing Panel / MCCB DB , complete with connections, testing and commissioning etc, as required. |
| 49 | Supplying and fixing 160A, 25kA, 4 Pole , 415V MCCB with thermal magnetic protection release including spreader in the existing LT panel complete with making necessary connections, testing and commissioning etc. as required. The work includes dismantling/removal of the existing 250A TP MCCB from the cubicle, modification of existing mounting arrangement, busbar extension/modification, provision of suitable copper/aluminium strips, drilling/cutting works, fixing of hylem sheets/insulation barriers, hardware fittings, supports and all allied works required for proper installation of the new MCCB in the existing cubicle complete as required. |
| 50 | Supply and fixing of Rotary Handle Extended ROM suitable for switches rated up to 250A including necessory arrangement for fixing on existing panel etc. as required. |
| 51 | Supplying and fixing 63 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCCB DB, complete with connections, testing and commissioning etc. as required. |
| 52 | Supplying and fixing 63 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Four pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required. |
| 53 | Supplying and fixing 16 A to 32 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Four pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required. |
| 54 | Supply Installation Testing and Commissioning of 28W 1200 mm sweep BLDC ceiling fan with input voltage range (140-285V), 380 rpm, Air delivery 235 m3/min, required length, painted down rod (GI) providing including connections etc. as required. |
| 55 | Providing and fixing fan hooks (S-Type), including drilling on the ceiling, making good the damages etc, as required. |
| 56 | Supply and fixing LED luminaire, complete with side holders and all other connecting equipments etc, as required.(T8 LED-Crompton TCS-726-20-65-SL-DP-NWH or compatible (4ft)-) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 57 | Supply and fixing of Box type tube fittings (Batten ), complete with side holders etc, as required.(Batten- Crompton ECO DIJB12LT8-20 1XT8 or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 58 | Supply and fixing of Box type tube fittings (Batten ) compatible for fixing 2 T8 LED tube light, complete with side holders etc, as required.(BattenCROMPTON - IIS-341-NWH or compatible) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 59 | Supply and fixing of surface mounting type (square type),or nearest size of 18 W, 1800 lm, 5700K, CRI >80, Efficacy >100 lm/watt, THD <10% cool white LED luminaire with white flat light opal diffuser, Robust PDC aluminum housing with LEDs complete with all accessories etc, as required. (Crompton -PEARL NIOS - S LCDSPLN-S-18-CDL or equivalent ) *** Bidder should submit OEM warranty certificate minimum 02 year or above along with supply of product at site. |
| 60 | Supplying and making end termination of PVC insulated copper conductor 4 x 16 + 2x6 sqmm submain wiring with suitable size Copper lugs etc as required. |
| 61 | Supplying and making end termination of PVC insulated copper conductor 4 x 10 + 2x6 sqmm submain wiring with suitable size Copper lugs etc as required. |
| 62 | Supplying and making end termination of PVC insulated copper conductor 2x6+ 1x6 sqmm submain wiring with suitable size Copper lugs etc as required. |
| 63 | Supply of 1.1 kV grade 4C x 50 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable(as per IS ) as required. |
| 64 | Supplying and fixing the identification details of cables and Distribution boards details with vinyl stickers/Paint on existing 4 nos of DB etc. as required. |
| 65 | Supplying and fixing 8 SWG copper wire on surface or in recess for loop earthing as required. |
| 66 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for 4 way Double door VTPN MCCB DB , 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. |
| 67 | Supplying and fixing 3 phase 4 way (4+12) double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB) |
| 68 | Supplying and fixing 4 pole MCB metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required. |
| 69 | Charges for removing the existing light fittings / fans and points, (All wires & PVC conduits) making good the damages of the wall / floor including painting other accessories without any damage and conveyance of the material to the godown etc, as required. |
| 70 | Removing of point wiring including cealing rose, conduit, wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard. |
| 71 | Removing of submain wiring including conduit, wires, clamps etc. as required and handing over to the store/yard. |
| 72 | Removing of switch board of any size including wires, switches(modular/piano type) switch board, clamps, GI/plastic box etc. as required and handing over to the store/yard. |
| 73 | Electrical Schematic drawing in Autocad and pdf format along with physical copy of the same for Electrical Inspectorate apptooval (along with seal, signature and License details of A class contractor) and complete assistance in obtaining the neccessory approval from the Electrical Inspectorate, ensuring that all compliance requirements and procedures are properly followed etc as required Please Enable Macros to View BoQ information |