| 1 | Centering and shuttering including strutting, etc. and removal of form for:Suspendedfloors, roofs, landings, balconies and access platform |
| 2 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 3 | Reinforced cement concrete work in walls (any thickness), including attachedpilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry150mm/230mm/300 mm thick with Grade- I AAC blocks in super structureabove plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 6 | Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 7 | providing Solid Wood Exterior Prehung Door Residential/commercial Use Featuring Waterproof And Anti-theft Properties In Customized Sizes |
| 8 | Providing and fixing steel window of size W3 including frame and shutter |
| 9 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 10 | 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost ofmaterials, labour charges etc complete |
| 11 | Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930with screws etc. complete : (Copper oxidized as per IS : 1378).300x20x6 mm |
| 12 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:100x10 mm |
| 13 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete |
| 14 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 15 | Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete asper manufacturer's specification and direction of Engineer-in-chargeExtruded sectionprofile size 48x40 mm |
| 16 | Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and railsmitred and joint at the corners by means of M.S. galvanised/plastic brackets of size75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles ofthe shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm(± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollowsection of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with auPVC multi-chambered single panel of size not less than 620 mm, having over allthickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled verticallyand tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod andfastened with nuts and washers, complete as per manufacturer's specification anddirection of Engineer-in-charge( For W.C. and bathroom door shutter). |
| 17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 500x500 mm |
| 18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 19 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm ormore (thickness to be specified by the manufacturer) of Ist quality conforming to IS:15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete |
| 20 | Providing and fixing vitreous china dual purpose closet suitable for use as squattingpan or European type water closet (Anglo Indian W.C. pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fittings and brackets, 40mm flush bend, 20 mm over flow pipe, with specials of standardmake and mosquito proof coupling of approved municipal design complete, includingpainting of fittings and brackets, cutting and making good the walls and floorswherever required:White vitreous china dual purpose WC pan with white solid plasticseat and lid with white vitreous china flushing cistern and C.P. flush bend |
| 21 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore |
| 22 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore |
| 23 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter |
| 24 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge |
| 25 | Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge |
| 26 | Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge |
| 27 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 |
| 28 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 29 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 30 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 31 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm |
| 32 | LS Amount for Electrification Please Enable Macros to View BoQ information |