|
| 1 | Supply of 3 core 2.5 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. | Supply of 3 core 2.5 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. |
| 2 | Supply of 4 core 4 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. | Supply of 4 core 4 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. |
| 3 | Supply of 4 core 10 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. | Supply of 4 core 10 sqmm, FR LSH PVC Insulated Industrial Grade Copper Conductor Flexible Cables, 1100 Volts Conforming to IS 694. |
| 4 | Supply of 3 to 3.5 mtr telescopic boom arm suitable for Time watch boom barrier | Supply of 3 to 3.5 mtr telescopic boom arm suitable for Time watch boom barrier |
| 5 | Supply of 400mm sweep pedestal fan with plastic body and blades, height adjustable with standard accessories suitable for operation on 230V, Single phase AC Supply etc., as required | Supply of 400mm sweep pedestal fan with plastic body and blades, height adjustable with standard accessories suitable for operation on 230V, Single phase AC Supply etc., as required |
| 6 | Supply of 400mm sweep wall fan with plastic body, mounting arrangement with standard accessories suitable for operation on 230V,Single phase AC Supply etc., as required. | Supply of 400mm sweep wall fan with plastic body, mounting arrangement with standard accessories suitable for operation on 230V,Single phase AC Supply etc., as required. |
| 7 | Supply of following, C curve, miniature circuit breaker suitable for operation on 230 415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 6 A to 32 A SP MCB | Supply of following, C curve, miniature circuit breaker suitable for operation on 230/415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 6 A to 32 A SP MCB |
| 8 | Supply of following, C curve, miniature circuit breaker suitable for operation on 230 415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 20 A DP MCB | Supply of following, C curve, miniature circuit breaker suitable for operation on 230/415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 20 A DP MCB |
| 9 | Supply of following, C curve, miniature circuit breaker suitable for operation on 230 415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 20 A TP MCB | Supply of following, C curve, miniature circuit breaker suitable for operation on 230/415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 20 A TP MCB |
| 10 | Supply of following, C curve, miniature circuit breaker suitable for operation on 230 415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 40 A FP MCB | Supply of following, C curve, miniature circuit breaker suitable for operation on 230/415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 40 A FP MCB |
| 11 | Supply of following, C curve, miniature circuit breaker suitable for operation on 230 415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 63 A FP MCB | Supply of following, C curve, miniature circuit breaker suitable for operation on 230/415 V, AC supply, 10 kA breaking capacity of following poles etc. as required. 63 A FP MCB |
| 12 | Supply of 40 A, double pole, residual current circuit breaker RCCB, having a sensitivity current 100 mA suitable for operation on 230 V, Single Phase AC supply etc. as required. | Supply of 40 A, double pole, residual current circuit breaker RCCB, having a sensitivity current 100 mA suitable for operation on 230 V, Single Phase AC supply etc. as required. |
| 13 | Supply of 63 A, four pole, 415 volts, residual current circuit breaker RCCB, having a sensitivity current 300 mA suitable for operation on 415 V, Single Phase AC supply etc. as required. | Supply of 63 A, four pole, 415 volts, residual current circuit breaker RCCB, having a sensitivity current 300 mA suitable for operation on 415 V, Single Phase AC supply etc. as required. |
| 14 | Supply of IRO Pro UO R Relay C and S make.Under Voltage Over Voltage Relay. | Supply of IRO Pro UO/R Relay C and S make.Under Voltage / Over Voltage Relay. |
| 15 | Supply of four pole, contactor with AC 1 rating 40A and 230V AC coil voltage | Supply of four pole, contactor with AC 1 rating 40A and 230V AC coil voltage |
| 16 | Supply of 2no plus 2nc 10A, contactor with 24V DC coil. | Supply of 2no + 2nc 10A, contactor with 24V DC coil. |
| 17 | Supply of 2no Contractor with 24 V DC coil. Make Schneider Model A9C20132 or equivalent | Supply of 2no Contractor with 24 V DC coil. Make Schneider Model A9C20132 or equivalent |
| 18 | Supply of 2MP Dome Camera suitable for existing CCTV system. Make Honeywell, Part no Impact I HEE2PL LP | Supply of 2MP Dome Camera suitable for existing CCTV system. Make Honeywell, Part no Impact I HEE2PL LP |
| 19 | Supply of 2MP Bullet Camera suitable for existing CCTV system. Make Honeywell, Part no Impact I HIBB2PI LP | Supply of 2MP Bullet Camera suitable for existing CCTV system. Make Honeywell, Part no Impact I HIBB2PI LP |
| 20 | Supply of Media Converter suitable for existing CCTV System. Make TRICOM | Supply of Media Converter suitable for existing CCTV System. Make TRICOM |
| 21 | Supply of POE switch 8 port suitable for existing CCTV System. Make Dlink. | Supply of POE switch 8 port suitable for existing CCTV System. Make Dlink. |
| 22 | Supply of SIM based GSM Autodialer along with 24V 2amp SMPS suitable for existing fire alarm system including . Make pinnacle. | Supply of SIM based GSM Autodialer along with 24V 2amp SMPS suitable for existing fire alarm system including . Make pinnacle. |