| 1 | 1.0) RMO of IEI installation, Fire Fighting, Fire Alarm with PA system, compound lighting & water supply pump set, maintenance of IEI installation of lift and operation of lift on non-booking days at following sites, as per the inventory, terms & condition and deploying the following manpower on one visit in a week:(a) Wireman cum DG Set/Pump/Fire/Lift Operator (Grade II) - 1 No.(b) Khallasi - 1 No.As sites as below:- |
| 2 | a) Community Hall at sukh vihar |
| 3 | b) Community Hall at Vishwas Nagar |
| 4 | c) Community Hall Shastri Park |
| 5 | d) Community Hall East of Loni Roa |
| 6 | e) Community Hall Vivek Vihar |
| 7 | f) Community Hall Kondli Extension near DDA Housing Kondli Gharoli Complex |
| 8 | g) Community Hall Chilla Village Mayur Vihar Phase-I |
| 9 | h) Community Hall Lahori Colony near SDM office |
| 10 | i) Community Hall Anand Vihar |
| 11 | j) Community Hall Badarpur |
| 12 | 2.0) RMO of IEI installation, Fire Fighting, Fire Alarm with PA system, compound lighting & water supply pump set, maintenance of IEI installation of lift and operation of lift on booking days at sites as mentioned in Annexure-A as per the inventory, terms & condition and deploying the following manpower on booking days for two shifts : |
| 13 | (a) Wireman cum DG Set/Pump/Fire/Lift Operator (Grade II) - 1 No. |
| 14 | (b) Khallasi - 1 No |
| 15 | 3.0) Servicing of existing installed different capacity of DG set, 3 phase, 440 volts along with supply and replacement of following worn out parts such as Air filter, oil filter, engine oil, i/c testing, commissioning and cartage etc. complete as required with a less rebate for dismantled material. |
| 16 | 3.1) 15 KVA |
| 17 | 3.2) 62.5 KVA |
| 18 | 4.0) Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).18-22 Watt |
| 19 | 5.0) Lifting of existing submersible pump set i/c GI pipe and dismantling of cable upto reqd. depth etc. complete as reqd. |
| 20 | 6.0) Lowering of existing submersible pump set i/c re-assembling of GI pipe, connection, testing etc. complete as reqd. |
| 21 | 7.0) Repairing & rewinding of following rating submersible pump set (Motor & Pump) i/c remettling of impeller, bush, neck ring etc. complete as reqd. 3 to 5 HP Submersible pump set |
| 22 | 8.0) Rewinding of Exhaust fan/ 48\\"ceiling fan oiling, greasing, servicing, cleaning, dismantling and re-assembling along with testing, commisioning etc. as required. |
| 23 | 9.0) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | 9.1) Single pole |
| 25 | 9.2) Double pole |
| 26 | 9.3) Triple Pole and Neutral |
| 27 | 10.0) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required. |
| 28 | 10.1) 100 A, 16 KA,TPMCCB |
| 29 | 10.2) 125 A, 16 KA,TPMCCB |
| 30 | 10.3) 125 A, 36 KA,FPMCCB |
| 31 | 10.4) 250 A, 36 KA, FP MCCB |
| 32 | 11.0) Servicing of existing 1.5/2 Ton air conditioners installed at Sukh Vihar Community Hall and Vishwas Nagar Community Hall including proper cleaning with blower, replacement of any defective part, chekcing of leakage & rectify if any and refilling of refrigerant etc. complete as required |
| 33 | 12.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel/ PVC conduit as required. the existing surface |
| 34 | 12.1) 1 x 1.5 sq. mm |
| 35 | 12.2) 3 x 2.5 sq. mm |
| 36 | 12.3) 3 x 4 sq. mm |
| 37 | 13.0) Supplying & replacement and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 38 | 13.1) 5/6 amps switch |
| 39 | 13.2) 15/16 A switch |
| 40 | 13.3) 3 pin 5/6 A socket outlet |
| 41 | 13.4) 6 pin 15/16 A socket outlet |
| 42 | 14.0) Checking and refilling of Carbon di oxide (CO2) type fire extinguisher for repairing if damage found in valve,gauge,hanger the cylinder & refixing the same in its original position after refilling etc. as required to make it funcitional & nothing extra shall be paid on this account. |
| 43 | 15.0) Supply and Replacement of worn-out/out of order of the following accessories i/c testing and commissioning etc as reqd |
| 44 | 15.1) Capacitor 2.50 micro Farad for ceiling fan |
| 45 | 15.2) Capacitor 4 micro Farad for exhaust fan |
| 46 | 16.0) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 47 | 17.0) Supply & replacement of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 48 | 18.0) Supply Replacement & installation of exhaust fan(metallic body) of size 300 mm or 12\\" i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts with testing & commissioning etc. complete as required. |
| 49 | 19.0) Replacement & installation of exhaust fan(metallic body) of size 450 mm or 18\\" i/c connections,making good the damages ,iron angle & painting with screws,nuts & bolts with testing & commissioning etc. complete as required. |
| 50 | 20.0) Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 51 | 20.1) 20 mm |
| 52 | 20.2) 25 mm Please Enable Macros to View BoQ information |