| 1 | M&L for PCC type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregates as in roof kerbs or mud stops, rounded or chamfered on edges etc including necessary form work, complete all as specified & directed. |
| 2 | M&L for PCC type B-1 (1:2:4), using 20 mm graded crushed stone aggregates as in padding in roof including necessary form work, complete all as specified & directed. |
| 3 | M&L for Brick work using fly ash/Sub class B bricks straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified & directed. |
| 4 | M&L for brick work half brick thick wall using Fly ash bricks as specified in straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified. |
| 5 | M&L for RCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like , including necessary formwork complete all as specified and directed. |
| 6 | S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, holing ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 7 | M&L for cutting grooves in brick wall 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed. |
| 8 | M&L for raking out joints/ pointing to brick work or brick tiles, laid flat as in floors, surface channels, roofs etc built in cement mortar complete all as specified and directed. |
| 9 | M&L for flush pointing with 1:3 cement mortar to brick work or brick tiles, laid flat as in floors, surface channels, roofs etc. Complete all as specified and directed. |
| 10 | Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered/RCC surfaces, making the surface completely dry and applying evenly a tack coat of industrial bitumen primer, having density in range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 70 to 160 CPS, manufactured by same manufacturer @ 0.4ltr/sqm shall be applied and after drying of primer for 24 hours apply APP modified water proofing membrane with non-woven polyester reinforcement,3mm thick superior multipolymeric, weighing not less than 3.00 Kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene(MHHDPE) film consisting of five layers laid with torching application to the surface complete and sealing the side as well as end laps with torch(Overlaps should not be less than 10cm in longitudinal direction and 15cm in transverse direction and shall be bonded with bitumen primer and levelled by heating the overlaps with brutane torch.) complete all as specified and directed. |
| 12 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection> 0.70 and initial remittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and joints are thoroughly filled with Epoxy Grouting all as directed, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed . |
| 13 | M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:6 with jointing & pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. |
| 14 | M&L for 40mm thick brick tiles (EXCEPT TILES) laid on 15mm screed bed in cement mortar 1:6 with jointing & pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. |
| 15 | M&L for 40mm thick average consolidated thickness, mud phuska on flat roof including 25mm thick mud Mortar, complete all as spd and directed. |
| 16 | M&L for cutting out natural vegetation plants grown up on wall or on roof and making good the damaged portion to match with the existing cement concrete complete all as specified and directed. |
| 17 | M & L for rendering 10 mm thick on fair faces of brick wall finished fair & even in CM 1:4 complete all as specified and directed. |
| 18 | M&L for preparation of new surface of wall and applying two coats of Cement base paint over one coat of primer complete all as specified and directed. |
| 19 | M & L for steel tubing 20 mm bore dia, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including dismantling old, complete all as specified and directed. |
| 20 | M & L for steel tubing 15 mm bore dia, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including dismantling old, complete all as specified and directed. |
| 21 | S&F in repair Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipe and fixed, Bore dia of pipe in 20mm, etc. complete all as specified and directed. |
| 22 | Disconnecting existing tanks of capacity exceeding 250 litre but not exceeding 500 litre, setting aside (or lowering if required) for cleaning/roof repair etc. and hoisting, reconnecting and re-fixing in position after necessary cleaning by removing all scale and dirt etc. including cleaning mouth of circulating service pipes complete all as specified and directed. |
| 23 | Disconnecting existing tanks of capacity exceeding 500 litre but not exceeding 1000 litre, setting aside (or lowering if required) for cleaning/roof repair etc. and hoisting, reconnecting and re-fixing in position after necessary cleaning by removing all scale and dirt etc. including cleaning mouth of circulating service pipes complete all as specified and directed. |
| 24 | S&F in repair 500 litre capacity three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connection, complete all as specified including the following accessories: -(i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified.(iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, complete all as specified.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP. |
| 25 | S&F in repair 1000 litre capacity three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, omplete all as specified including the following accessories: -(i) PTMT ball valves, high pressure, with epoxy coated aluminium rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, complete all as specified.(iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, complete all as specified.(iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP. |
| 26 | S & F in repair for PVC (SWR) pipes single socketed, in any length with or without rubber ring joints, laid under floor/ fixed to walls, bore of pipe 110 mm, etc complete all as specified and directed. |
| 27 | S & F in repair for PVC (SWR) bends any radius, bore of pipe 110 mm, etc complete all as specified and directed. |
| 28 | S & F in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall , bore of pipe in 75 mm, etc complete all as specified and directed. |
| 29 | S & F in repair for PVC (SWR) bends any radius, bore of pipe in 75 mm, etc complete all as specified and directed. |
| 30 | Taking down Cement plaster or cement lime plaster any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 31 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all specified and directed. |
| 32 | Dismantling brick tiles in roof laid dry and pointed in cement mortar complete all as specified and directed. |
| 33 | Demolition of mud phuska in roofs of any thickness including leaping plaster complete all as specified |
| 34 | Demolition of reinforced cement concrete as in chimney, Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed. |
| 35 | Demolition of Concrete of any description and in any position not otherwise specifically provided for, cement concrete, etc complete all as specified and directed. |
| 36 | Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |