| 1 | Providing and fixing golden champ wood chowkhat (kiln seasoned) 4 1/2\\" x 2 1/4\\" including cost of corner straps, iron hold fasts, hinges, screws,nails, fevicol etc. and painting two coats of wood preserver to sides of chowkhats. Rate includes the cost of dismantling of all damaged chowkhats and making good the damage to walls plaster and floors as required including, refixing of grills, disposal of rubbish to the dumping ground the rate further includes the cost of painting two coats synthetic enamel paint over one coat of wood primer complete in all respect and to the entire satisfaction of Engineer-in-Charge. |
| 2 | Distempering with 1st quality acrylic distempe. (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required said and colour complete to give and even said.One or more coats on old work |
| 3 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.One coat |
| 4 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 5 | Painting with aluminium paint of approved brand and manufacture to give an even shade:One or more coats on old work |
| 6 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 7 | Preparation of plaster or concrete surface for oil bound distemper or emulsion or apex paint including sand papering the surface or scraping by patti applying filling with cement based putty (Birla, JK or equivalent) to required finish complete in all satisfaction of Engineer in Charge. |
| 8 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 9 | Providing and fixing barbed wire on existing picket with binding wire complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 10 | Providing and fixing 35mm thick phenol bounded factory manufactured solid flush door shutter ISI marked with both side commercial face in the existing chowkhat. The rate includes the cost of Alum hinges, all necessary Alum fittings and painting two coats over one coat of primer after preparation of surface (special quality) complete in all respect to the entire satisfaction of Engineer-in-charge. |
| 11 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 12 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 13 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 14 | Providing and fixing 4mm thick plain glass panes with beading when required over existing chowkhat or glazed shutter including the cost of nails, putty etc. complete in all respect to the entire satisfaction of Engineer-in-charge. |
| 15 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 16 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. with necessary screws to the existing wooden frame including coat of synthetic enamel paint over one coat of primer complete in all respects and to the entire satisfaction of the Engineer in charge. |
| 18 | Providing and laying water proofing coating having three coats of water proofing chemical with 1 coat as primer and 2 subsequent coats. The water proofing chemical shall have properties as water absorption 1% minimum, pot life at 30º C : 30 min, application temperature 10º C, bond strength to concrete : approx 1 N/mm2. (Fosroc Hydroproof xtra or equivalent) . The primer coat shall be provided in ratio 1 part of Hydroproof Xtra :2 parts of water : 4 parts of cement mixed material with the above proportion will cover an area of 16-17sqm for 1 L of Hydroproof XTRA . The two top coats shall laid in ratio 1:2 i.e. 1 part of chemical and 2 parts of neat cement after laying of 800 micron fibre mesh. The thickness of each coat shall be about 1 to 2 mm. The 2nd coat shall be applied after 5-6 hours of 1st coat. The full curing shall be done after 12 hours with must curing after 6 hours. The coverage of top coats shall be 4.5-5.0 sqm /litre/ coat. The work shall be undertaken as per manufacturer specifications, complete in all respect and to the entire satisfaction of Engineer in Charge. |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4(1 cement :4 coarse sand) |
| 20 | Providing and fixing IRC welded steel wire fabric of size 3\\"x1\\" wire of 12 gauge in existing angle iron frame properly welded to the frame with the help of existing MS Flat 25x5mm beading by cutting to the required size, straightening and pirmer in position complete in all respect and to entire satisfcation of Engineer-in-charge. |
| 21 | Renewal of old putty of glass panes (length) |
| 22 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60) |
| 23 | Cleaning of terrazo / kota / mosaic / red sand stone floors and skirting with grinding machine and polishing the floor include machine charges complete in all respects and to the entire satisfaction of the Engineer in charge. |
| 24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 25 | P/F 110mm internal dia PVC pipe as rain water pipe on walls of 6 kg. pressure with Bend, Elbow and Clamps complete in all respect to the entire satisfaction of Engineer--in-Charge |
| 26 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Please Enable Macros to View BoQ information |