| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 x 1.5 sq.mm:- |
| 9 | 2 x 2.5 sq.mm:- |
| 10 | 2 x 4 sq.mm:- |
| 11 | 4 x 10 sq.mm:- |
| 12 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required. |
| 13 | 1 x 1.5 sq.mm:- |
| 14 | 2 x 1.5 sq.mm:- |
| 15 | 2 x 2.5 sq.mm:- |
| 16 | 2 x 4 sq.mm:- |
| 17 | 4 x 6 sq.mm:- |
| 18 | 4 x 10 sq.mm:- |
| 19 | 4 x 16 sq.mm:- |
| 20 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required:- |
| 21 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 22 | Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required. |
| 23 | Providing and laying of 15 mm dia(medium guage) G.I Pipe for drawing of 4.06 mm (8SWG) dia copper wire for earth connection from earth electrodes etc as required |
| 24 | Providing andfixing of following sizes PVC Conduit (medium guage) on surface with all accessories etc. as required. |
| 25 | 19/20 mm dia |
| 26 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W). |
| 27 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 28 | Electronic 5 step fan regulator:- |
| 29 | Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 30 | Supplying & installation of shutter for 380/450 mm sweep metalic body exhaust fan in the existing hole as required :- |
| 31 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 32 | 2.5 mfd fan capacitor |
| 33 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 34 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 35 | Supplying and fixing of powder coated sheet steel enclosure on surface/recess, suitable for 240/415 volts MCB/ Isolator/ RCCB (SP/ SPN/ DP/ TP/ TPN/FP) complete with necessary bus bar, neutral link,din rail ,earth bar, etc. i/c connection as required . |
| 36 | 2 Way MCB DB (Single door):- |
| 37 | (2+4)/6 way MCB DB (single door):- |
| 38 | (2+6)/8 way MCB DB (single door):- |
| 39 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required: |
| 40 | 6 to 32 amps SP MCB:- |
| 41 | Supplying & installation of isolators of following ratings in the existing MCB DB including connection etc as required: |
| 42 | 40 amps DP isolator:- Please Enable Macros to View BoQ information |