| 1 | Cleaning of blockage of Indian / european type WC up to first manhole and making the drain pipe of any dia fully functional by flushing with water to entire satisfaction of Engr-in-Charge including disposal of sludge outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/ instructions of civil authority and burried in excavated pits complete all as specified and directed. Note:- Unit rate quoted by tenderer shall include clearing blockage, taking out sludge(liquid/semi liquid/solid ) , excavation of borrow pits for dumping sludge ,removing including loading/unloading and transportation etc. |
| 2 | Cleaning of blockage of Floor/Nahni/vermin trap of Kitchen/Bathroom/basin/sink/urinal etc upto & including gully trap by using hand pump with bucket or manually by rodding till clear flow of water is observed and removing the deposited sludge/solid/liquid material outside MD land, complete all as specified. |
| 3 | Cleaning of blockage of under ground sewer lines of any dia of pipe including manholes, gully traps etc. by means of cleaning by roding from manholes to manholes / inspection chamber to manholes / gully trap to inspection chamber and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and cover the pit, complete all as specified and directed.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit with & including removing of surbs, grass, small roots etc around manhole, inspection chamber etc where required is deemed to be included in the unit rate to be quoted by tenderer. |
| 4 | Cleaning of blockage of under ground sewer lines of any dia of pipe by breaking / puncturing of pipe line including excavation in type of soil to depth upto 3mtr deep, removing the blockage and making good the pipe line bedding, relaying of pipe and making good the earth excavated incl redressing complete all as specified and directed. |
| 5 | Opening of cover (of any description and size) of septic tanks and soakage well/ pits, desludging/ dewatering of septic tanks and soakage well/pits of any size and depth by manually operated machine (where approach for vehicle is not feasible) making it fully functional and removing sludge outside the periphery of defence land at his own arrangement at a minimum distance of 50 m from nearby living accn and burring in excavated pits including spraying of lime over returning filling of sand and covering the same including refixing covers after cleaning complete all as specified and all as directed by Engr-in-Charge. Note: Unit rate quoted by tenderer shall include taking out sludge from septic tank and soakage well/pits in ground with pit by excavation of borrow pits for dumping sludge, removing including loading/unloading and transportation etc. |
| 6 | Opening of cover (of any description and size) of septic tanks and soakage well/ pits, desludging/ dewatering of septic tanks and soakage well/pits of any size and depth by mechanical pumping truck mounted (having minimum storage capacity of 2500 ltrs) making it fully functional and removing sludge outside the periphery of defence land at his own arrangement at a minimum distance of 500 m from nearby living accn and burring in excavated pits including spraying of lime over returning filling of sand and covering the same including refixing covers after cleaning complete all as specified and all as directed by Engr-in-Charge. Note: Unit rate quoted by tenderer shall include taking out sludge from septic tank and soakage well/pits in ground with pit by excavation of borrow pits for dumping sludge, removing including loading/unloading and transportation etc. |
| 7 | Cutting and demolition of exising SGSW sewer pipe in damaged portion alongwith concrete bedding including removing unsv materials from site as directed and providing PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including packing under and haunching against the sides of pipe with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for 110 mm internal dia of sewer line, complete all as specified and directed.Note:- Earthwork like excavation, returning filling and removal required for the repair of said work shall be inclussived in the rate quoted by the contractor |
| 8 | Cutting and demolition of exising SGSW sewer pipe in damaged portion alongwith concrete bedding including removing unsv materials from site as directed and providing PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including packing under and haunching against the sides of pipe with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for 150 mm internal dia of sewer line, complete all as specified and directed.Note:- Earthwork like excavation, returning filling and removal required for the repair of said work shall be inclussived in the rate quoted by the contractor |
| 9 | Repairs to Rat / mouse holes to the faces / surfaces of manhole by making good to wall surface, benching, drains / channel etc of sectional area not exc 150sqcm each and depth n.exc 25cm each and filling the same with plain cement Concrete 1:2:4 type-B-1 (using 20mm graded crushed stone aggregate) and finished the surfaces even and fair, complete all as specified and directed. |
| 10 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed. |
| 11 | M&L for Precast reinforced cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) including necessary form work complete all as specified and directed by Engineer-in-Charge.Note:- Reinforecement shall be measured & paid seperately under relevent item. |
| 12 | S&F TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 13 | 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed in repair all as specified and directed. |
| 14 | 75mm bore PVC (SWR) bends any radius fixed in floor in repair |
| 15 | 75mm bore PVC (SWR) junction single, (Single T) equal or unequal fixed in repair |
| 16 | 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with GI/Alu clamps fixed in repair all as specified and directed. |
| 17 | 110 mm bore PVC (SWR) bends any radius fixed in repair all as specified and directed. |
| 18 | 110mm bore PVC (SWR) vent cowl fixed in repair all as specified and directed |
| 19 | Dismantling fencing wire mash any type and size |
| 20 | Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground. |
| 21 | Excavating in post holes Hard/dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface |
| 22 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggr as in foundation filling and mass concrete complete all as specified. |
| 23 | S&F Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc as directed (each line wire to be mesured) |
| 24 | S&F MS angle iron posts and struts in fencing/gates including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming |
| 25 | S & F only Mild steel in flat, round bars, in available lengths quality con-forming to Fe- 290 (Gde E- 165) |
| 26 | Supply only 3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied with posts properly comlete all as directed. |
| 27 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 28 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 150 mm & dia of neck 11 to 15mm Complete |
| 29 | M&L for preparation of new wooden surfaces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directeed by EIC |
| 30 | Preperation of newly steel surface of any description ,not otherwise described over 10cm witdth or girth and applying two coat of synthetic enamel paint over a coat of pink primer all as spd and directed |
| 31 | M&L for 75 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed |
| 32 | Material & labour for prepolished chequered cement concrete tiles 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified & directed. |
| 33 | Dismantling of Stone sett paving laid dry or laid dry and pointed of any description or thickness in floors,apron complete all as specified, |
| 34 | M&L prepolished Machine pressed precast concrete coloured Inter locking paver block of any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over sand cushion & laid over sub base all as specified and directed. |
| 35 | Description all as per Ser item No 34 above but expect tiles |
| 36 | M & L Sand filling under floors including watering and consolidation |
| 37 | M&L Cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, coping, window cill etc complete. |
| 38 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete. |
| 39 | M & L rendering 15 mm thick in CM 1:6 in on surface of walls and finished even and fair (without using extra cement) in patches. |
| 40 | Taking down cement plaster on brick or concrete or stone walls etc including racking out joints hacking for key scrubbing down with water any description. |
| 41 | M&L PCC (1:2:4) type B1 using 20mm graded stone aggregate in coping etc, including weathering slightly rounded champers angle forming channels & form work |
| 42 | M&L forming fair finished drain or channel, 30 cm inner girth, cement concrete finished even and smooth, using extra cement including forms moulds etc. |
| 43 | Demolition of reinforced cement concrete of any description in any position not otherwise described complete. |
| 44 | M&L pre cast RCC (1:1.5:3) type A-1 as in manhole cover, drain cover and set in cement mortar (1:4) including necessary formwork complete. |
| 45 | M&L mild steel TMT bar 10mm dia and over cut length cut to length bent to shape required including cranking bending and binding with MS wire not less than 0.9mm dia or securing clips |
| 46 | Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete all as specified and directed. |
| 47 | M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete. |
| 48 | M & L preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer complete as specified and directed. |
| 49 | M & L complete removal of existing treatment on wall and applying one coat of Cement base paint all as specified and directed. |
| 50 | M&Lcomplete removal of existing treatmenton wall and applying two coat of cement paint on Complete removal of existing old surfaces on wall , etc complete all as specified and directed. |
| 51 | M&L in repair type C1 1:3:6(20mm graded aggregate) precast cement concrete in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham fers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match all as spd and direcetd |
| 52 | M&Lin repair Type B0 1:2:4 (12.5mm graded aggregate) precast cement concrete louvres and jallies, 25mm thick (mea sured solid), including all mould (Pre cast frame shall be measured separately and paid) set in cement mortar 1:4 all as spd and direceted. |
| 53 | Demolition and breaking of drain pipes of 110/75mm size etc complete all as specified & directed. |
| 54 | Material & labour for 75mm bore PVC floor traps plain fixed in repairs including jointing with solvent cement complete all as specified & directed. |
| 55 | M&L for 100mm dia Cast iron Nahani trap with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) |
| 56 | S&F grating doom 125mm dia of steel (Minimum weight 25gms). |
| 57 | Taking up or steel tubing & connections including cleaning for refixing bore of pipe 15mm etc complete all as specified and directed |
| 58 | Description all as per Ser item No 58 but 20mm bore |
| 59 | Supplying and laying of CPVC pipes 25 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors(including all necessary fittings) complete all as specified. |
| 60 | Supplying and laying of CPVC pipes 20 mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all necessary fittings complete all as specified. |
| 61 | S&F in repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed . |
| 62 | S&F in repair for Gun-metal, globe or gate valves 15mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed . |
| 63 | S&F in repair bib tap 15mm fancy type of PTMT any colour high pressure screwed for iron pipe and fixed complete all as specified and directed . |
| 64 | S&F in repair bib tap 15mm chromium plated fancy type long shank with crutch butterfly handle, screw down screwed for iron pipe or for brass ferrule etc complete all as specified and directed . |
| 65 | S&F in repair stop valve 15mm chromium plated screw down, high pressure with crutch or butterfly handle, screwed fboth ends for or iron pipe or for unions and fixed complete all as specified and directed |
| 66 | Description all as per Ser item No 66 but two way angle cock |
| 67 | S&F in repairs Health faucet(ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in complete all as specified & directed. |
| 68 | S&F in repairs 15mm dia pillar tap cost copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without letered \\"Hot or Cold\\" high pressure with long screwed shanks & fly nuts screwed for iron pipe etc complete all as specified and directed |
| 69 | S&F in repairs 15 mm dia concealed type stop valve fancy type chromium plated etc complete all as specified and directed |
| 70 | S&F in repair Brass chromium plated shower rose 125mm size fancy type with or without swelves joint fixed to iron pipe etc complete all as directed and spd. |
| 71 | S&F in repairs looking mirror 600x450mm selected quality 5mm thick glass mounted on 6mm ply wood & fixed with brass screw & cup washer |
| 72 | S&F in repair PVC connection 450mm long with two PTMT nuts (Prayag) |
| 73 | S&F in repair CP towel rail, 20mm dia, D type,60cm long complete all as approved and directed by the EIC |
| 74 | S&F in repair 32mm bore low density polyethylene (LDPE) pipes of pressure rating 6kgf/sqcm Complete. |
| 75 | S&F in repair vitreous china squatting pan, Orrissa pattern size 580x440mm white with PVC 'P' or 'S' trap with integral foot rest of any pattern incl connection to trap & to flushing pipe, antisyphonage pipe etc making good to floor complete. |
| 76 | S&F in repair Vitreous china wash down water closet pan ( pedestal pattern), white (excluding fixing bolt, flushing cistern and flush pipe) but including P or S trap, and sheet cover all as directed and specified. |
| 77 | S&F in repair vitreous china wash hand basin, white, flat back, size 550x400 mm incl chain and plug and porcelain stopper, brackets, waste pipe incl cutting for and pinning in ends of brackets or erecting stand including dismantling |
| 78 | S&F in repair PVC flushing cistern 10 ltr capacity including bracket fixed to wall & flush pipe complete ISI marked |
| 79 | S&F in repair, plastic water closet seat cover, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device for pedestal pattern WC, black/ white colour. |
| 80 | S&F in repair,Toilet paper holder of with flat recessed type stainless steel fixed to walls with chromium plated(CP) brass screws complete all as specified and directed |
| 81 | S&F in repair Vitreous China urinal,Half stall type White(excluding waste Pipe) complete all as specified and directed |
| 82 | M&L cement concrete (1:4:8) type D2 using 40mm graded stone aggregate in fondation and mass concrete for manhole surface channels and drains |
| 83 | M&L rendering 15mm thick cement mortar (1:4) on fair faces of brick or concrete surfaces and finished even and fair without using extra cement. |
| 84 | S&F TMT bars, 10mm and over dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking,cover slabs ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 85 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete. |
| 86 | M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete |
| 87 | M&L coloured ceramic glazed tiles 375x250x7mm/ 450x300x7mm thick as in dado/skirting etc including 10 mm thick rendering in CM 1:3, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement. |
| 88 | S&F in repair PVC ball valve 15mm dia with epoxy coateed aluminium rod and high density ball (minium weight 142 gms) complete as directed by Engr-in-charge. |
| 89 | S&F in repair PVC ball valve 20mm dia with epoxy coateed aluminium rod and high density ball (minium weight 210 gms) complete as directed by Engr-in-charge. |
| 90 | Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 250 litres & n exc 500 litres |
| 91 | Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 500 litres & n exc 1000 litres |
| 92 | Cleaning and removing all scale and dirt etc by using bleaching powder from water tank and from mouth of circulating pipe,etc Capacity of tank Capacity of tank exc 1000 litres & n exc 2000 litres |
| 93 | Material & labour for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 94 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 95 | M&L for preparation of old steel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxide primer and applyinng one coats of synthetic enamel paint of approved shade complete all as specified and directed. |
| 96 | M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 |
| 97 | Description all as per Ser item No 99 but except bricks |
| 98 | M & L for preparing old plastered surfaces of wall and applying one coat of Cement base paint all as specified and directed. |
| 99 | M&L Cement concrete in in eight,copings, kneelers, apex stones, bed plates, kerbs (1:2:4) type B-1( 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismi cand other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight,copings, kneelers, apex stones, bed plates, kerbs |
| 100 | M& L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges PCC 1:2:4 type B-1 using 20mm graded aggregate Complete all as specified and as directed. |
| 101 | M&L Cement concrete in surface channels and drains 1:3:6 type C-2 (40mm graded aggregate)as finished the surface even & fair complete all as specified |
| 102 | M & L for preparing old plastered surfaces of wall and and applying one coat of distemper oil emulsion, white or tinted complete all as directed. |
| 103 | Complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces and preparation of surfaces for further treatment and applying two coats of distemper, oil emulsion white or tinted complete. |
| 104 | M & L for complete removal of existing treatment over wall and applying two coats of distemper oil emulsion over 2mm thick wall care putty complete all as directed |
| 105 | M & L for preparing old plastered surfaces of ceiling and and applying one coat of distemper oil emulsion, white or tinted complete all as directed. |
| 106 | M & L for preparing old plastered surfaces of wall and applying one coat of white wash on walls |
| 107 | Description all as per Ser item No 108 above but on ceilings |
| 108 | M&L finishing walls on Complete removal of old prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete. |
| 109 | M&L for preparation of old wooden surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint white or tinted complete all as directed. |
| 110 | M&L for preparation of old painted steel surface of any description , over 10 cm width or girth not otherwise described and applying one coat of synthitic enamel paint white or tinted all as directed. |
| 111 | 10mm thick cement plastering in cement mortar 1:4 with WPC on fair faces of brick work or concrete surfaces finished even & fair without using extra cement complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete. |
| 112 | M&L three coat of white wash on Newly plaster surfaces on wall , etc complete. |
| 113 | M&L Preparing New putty wall surfaces, priming plastered and other surfaces with alkali resistant primer and applying two coats of oil bound distemper over 2 mm thick wall putty of any shade on walls surfaces |
| 114 | S&F in repairs IVC hand shower (Health faucet) with 8mm dia, 01 (one) metre long CP tube and wall hook with matel body complete all as specified & directed. |
| 115 | S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washers, waste coupling, waste pipe incl bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as directed and specifed . |
| 116 | S&F in repairs shower rose brass cromium plated with swivel joints of size 75 mm dia cast copper alloy CP, fancy type with CP neck 6\\" long made to shape comptete. |
| 117 | S&F in repair 15mm dia central hole basin mixer with Any shaped round cated spout with 450mm long braided hoses (hot & cold)all as specified. |
| 118 | S&F in repair 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed compete.. |
| 119 | M&L 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete. |
| 120 | M&L double action floor spring for aluminium doors hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed including necessary cutting & making good to floor as per existing complete all as specified and directed.Make - Kelwyn / Amar |
| 121 | S&F Aluminium fanlight pivot with plate size 25mmx65mm and suitable for shutter of 35mm thick complete. |
| 122 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples |
| 123 | S&F in repairs mirror cabinate all as specified and directed. |
| 124 | S&F in repair MS conduit curtain rod with PVC coating fancy type drafry rod 20mm dia of any colour as approved and fixed to rackets all as specified and directed. |
| 125 | S&F fancy type sofia brakcet for the curtain rod (suitable for 20mm dia curtain rod) of any approved colour and design all as specified and directed. |
| 126 | Demoliton of cement concrete in ground floor paving n exc 15cm thickness ( below or above ground level ) complete. |
| 127 | M & L for 75 mm thick PCC 1:3:6 type C-2 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. |
| 128 | Hacking out old boken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with oil putty or fixed with beads complete. |
| 129 | S& F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n. Exc 0.5 Sqm in each pane. |
| 130 | Taking up or down steel tubing and connection 20 mm bore pipe and removing from site complete all as specified and directed . |
| 131 | Taking up or down steel tubing and connection 15 mm bore pipe and removing from site complete all as specified and directed . |
| 132 | Supplying and laying of 16mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 133 | Supply and fix PVC Pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc. 75mm bore as in waste and rain water pipes complete all as specified & directed. |
| 134 | Supply and fix PVC Pipes single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc. 110 mm bore as in waste and rain water pipes complete all as specified & directed. |
| 135 | Supply and fix PVC bends 75mm bore, any radius complete all as specified & directed.(ISI Marked) |
| 136 | Supply and fix PVC bends 110 mm bore, any radius complete all as specified & directed.(ISI Marked) Please Enable Macros to View BoQ information |