Name of Work:- Repair and renovation works for Shifting and Establishment of Blood Centre of Contai SDH, Nandigram HD --- SITC of Fire Alarm System.
Sl. No.
Item Description
1
Supply, Installation, Testing & Commisioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel ( VDS / UL / LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 320 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store minimum 4000 log eventsin its memory (EPROM). The panel should have extra loop card slot for future expansion. Two Loop Panel.
2
Supply, Installation,Testing & Commisioning of Micropresssorcontrolled Addressable Multisensor detector ( VDS / UL / LPCB /FM approved ) with inbuilt optical smoke sensors and heat detectorsensor with inbuilt short circuit fault isolator as per NFPA (Note :Detectors without built-in fault isolator is also acceptable with oneindependent short circuit fault isolator after every four (04) detector isto be provided without extra cost) the detectors should have built inresponse indicator with LED indicator. The detector should have 360degree optical view with single / multiple LED that blinks onactuation of detector. Reverse polarity or faulty zone wiring shall notdamage the detectors. Degree of protection as per OEM Standard.
3
Supply, Installation, Testing & Commissioning of Addressable LoopPowered /panel powered Hooter (sound output of minimum 90 db )cum strobe (strength of light 10 cd) complete with inbuilt short circuitfault isolator as per NFPA (Note :Hooter without built-in fault isolatoris also acceptable with one independent short circuit fault isolator isto be provided without extra cost). ( VDS / UL / LPCB / FM approved) approved. Degree of protection as per OEM Standard.
4
Supply, Installation,Testing & Commisioning of Addressable ManualCall Point ( VDS / UL / LPCB / FM approved ) with in built shortcircuit fault isolator as per NFPA (Note : MCP without built-in faultisolator is also acceptable with one independent short circuit faultisolator is to be provided without extra cost). Degree of protection asper OEM Standard.
5
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision MMS) on the surface of the wall. Please Enable Macros to View BoQ information