| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | Supplying and laying of quarry stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage cjob |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) |
| 4 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 5 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works upto plinth level |
| 6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations: footings, bases of columns etc. for mass concrete. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Columns, pillars, piers, abutments, posts and struts. |
| 12 | Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 14 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 15 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 16 | 20mm Cement plaster of mix:1 : 4 ( 1 cement : 4 fine sand) including making boders etc |
| 17 | 12mm Cement plaster of mix 1 : 4 ( 1 cement : 4 fine sand) |
| 18 | Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) including curing.One face dressed Fine chisel dressed |
| 19 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 Coarse sand) including pointing in white cement mortar 1:2 (1 cement : 2 Stone dust) with an admixture of pigment matching the stone shade, Jali slab without any chamfers etc and curing complete.White sand stone |
| 20 | Stone tile work for wall lining upto 20 m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade Granite stone of any colour and shade including moulding wherever required complete job |
| 21 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete. |
| 22 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 23 | Providing and fixing Tile Profile precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including all lifts,leads and carriages complete job |
| 24 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 25 | Providing and fixing plained eaves boarding. 2nd class Kail Wood 300x40 mm (nominal size) complete job (Ornamental type) |
| 26 | Providing and fixing of 19mm thick compacted plyboard including cost of fixing to rotary ceiling with screws of required size complete job |
| 27 | Providing and fixing of KHATAM BANDI ceiling of first class budloo/ fir wood excluding the cost of frame work which is to be paid separately.Chaar Gul including cost of wastage carriage cjob |
| 28 | French spirit polishing, Two or more coats on new works including a coat of wood filler |
| 29 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 30 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 31 | Making oramental boders, strips, design in POP including cost of material labour and carriage up to site of work (As per approved design) in any shape and size in façade of clock tower complete job |
| 32 | Carriage of material from approved source upto site of work by M/T Stone agg for an average lead of 15 KM |
| 33 | Carriage of material from approved source upto site of work by M/T Sand for avg lead of 20 Km |
| 34 | Carriage of material from approved source upto site of work by M/T Bricks for avg lead of 12 km |
| 35 | ELECTRIC ITEMS Wiring for First light point/ exhaust fan point/ call bell point (wiring from distribution board to first point via switch board) with 2x1.5 sq.mm FRLS PVC insulated copper conductor single core cable confirming to IS:694 in surface / recessed medium duty minimum 2mm thick FRLS existing PVC conduit as per IS:9537 Part-3 latest as on date, include the cost of SITC of modular type switch & modular plate with base, suitable minimum 0.8mm thick GI box, circuit wiring 2X2.5 sq.mm (P,N) FRLS PVC insulated copper conductor single core cable from switch board to Distribution Board etc. as required. (All Switchs Should be Anti-Bacterial) |
| 36 | Wiring for 240 volt single phase and neutral 6 amps switch socket outlet with 2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or surface mounted 25 mm dia 2 mm thick existing PVC conduit, including the cost of SITC of 6 amps 5 pin Modular type switch socket of approved make colour and design in 1.6 mm thick GI box with grid plate and earthing of third pin of the socket outlet and the GI box with 2.5 Sq.mm PVC insulated copper conductor stranded flexible FRLS wire etc. as required.(Cost of Switch & Socket is included).(All Switchs & Sockets Should be Anti-Bacterial) |
| 37 | Wiring for 250 volts single phase and neutral 16A Power Plug point with 2x4.0 sq. mm FRLS PVC insulated copper conductor single core cable confirming to IS:694 in surface/ recessed medium duty minimum 2mm thick FRLS existinng PVC conduit as per IS:9537 Part-3 latest as on date, including the cost of SITC of modular type 16A switch with indicator of 'ON', 5 pin Shuttered type 6/16A Socket & modular plate with base and minimum 0.8mm thick GI box and earthing the point wired with 1x4.0 sq.mm FRLS PVC insulated class 2 copper conductor single core cable confirming to IS:694 etc. as required. (Cost of Switch & Socket is included).(All Switchs & Sockets should be Anti-Bacterial) |
| 38 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 4 sq. mm + 1X 4 sq. mm earth wire(in minimum 25mm) |
| 39 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 10 sq. mm + 1X 6 sq. mm earth wire(in minimum 25mm) |
| 40 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 41 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 42 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 43 | Supplying and fixing following rating, double pole, 240 V, MCB(10kA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A |
| 44 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 45 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB |
| 46 | Supply, installation, testing, commissioning LED Flood light luminaire (IP66), BIS certified with a body of high pressure die cast aluminium, flat toughened glass protector (IK07) and a white polycarbonate film reflector around LEDs. Several optical options for symmetric light distribution with 30°, 60° or 90° beam angles. Bracket suitable for a wall, ground or high mast mounting and pre-cabled as required. Overall luminous efficiency of 120lm/W at correlated colour temperature (CCT) of 5700K (optional 3000K & 4000K), colour rendering index (CRI) >70and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV from 100W and above (in both Common & Differential Modes).Offered Wattage - 100W, 120Lm/W Total Lummens - 12,000 |
| 47 | Supply, installation, testing, commissioning and numbering of LED wall bracket decorative light. |
| 48 | Supply, installation, testing, commissioning and numbering of decorative chandlier in ceiling. |
| 49 | Supply, installation, testing, commissioning and numbering of Philips 3W UNIIn-ground Ground Burial 3000K Landscape Light, BBP340 LED220/WW 20 PRODUCT SPECIFICATIONSBrand Philips Protection Class IP68, Type-BBP340 LED220/WW 3W 20D 100-240VHousing Material Aluminium Input Power 3 W Voltage 100-240 V Model UNIIn-ground Ground Burial-Colour Correlated Temperature-3000K Notes Image is only for reference purpose ColourWarm White |
| 50 | Supply, installation, testing and commissioning of 3kVA, 1 Phase, 240V, Pure sine wave Inverter alongwith lead acid batteries CSB/Exide make giving a back up of min. 1.5 hrs. at full load as per specification alongwith PVC/M.S Poweder coated cabinet with unidirectional wheels for housing the inverter and batteries, complete as required and as per specifications.Note: Battery bank sizing calculations shall be submitted for approval along with shop drawings. |
| 51 | Providing & fixing of Tower Clocks Material:Glass & Crystal, Metal, Shape: Geometric, Round Shape, Wall Clock Type: 12 mm Sheet, Type: Mechanical, Stainless Steel Frame/Fluorine carbon coating, Aluminum Dial,Different numerals availableChiming each hour(except for from 9:00pm-6:00am, optional ) , Automatic night light turn on & off system Inset-Mount TOWER CLOCKS: >/=72″ dia. (72″ diameter and larger) Please Enable Macros to View BoQ information |