| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER BAREILLY Name of Work: SPECIAL REPAIRS TO BLDG NO T-62 (NIGHT STANDING) MULES LINES OF 'B' COY OF 883 AT BN ASC UNDER GE (EAST) BAREILLY Contract No : CWE / BLY / GE(E) /21 OF 2026-27 Bidder Name : SCHEDULE A(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling Asbestos cement sheet(corrugated ted, semi corrugated, etc.) sheets in roof coverings up to height 5mtr complete all as specified and directed. |
| 3 | Dismantling Unframed work timber scantlings 40 sq. cm and over in section, in any position etc complete all as specified and directed. |
| 4 | Demolition of Ceemnt concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed. |
| 5 | M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J-type or cranked hook bolts complete all as specified and directed. |
| 6 | M&L for 6mm thick Asbestos cement apron piece 6mm thickness to suit corrugated or semi corrugated sheets as in ridges fixed with Ltype or J-type or cranked hook bolts. complete all as specified and as directed. |
| 7 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins, vertical post where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde- E-250) quality-A complete all as specified and directed. |
| 8 | S&F mild steel hand rails, half round or other mild steel section or core for wooden hand-rail straight portion, mule drum etc or drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shapeas directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 9 | S&F mild steel screw bolts (Machine made) with hexagonal or square heads at one end and the screwed the other to be fitted with washers and one hexagonal or square but exc 5 cm but n.exc 10 cm long, dia of shank 5 to 10 mm complete all as specified and directed. |
| 10 | M&L for cement concrete 1:4:8, type D-2, usng 40 mm graded broken stone aggregate 75 mm thick as sub base complete all as specified and directed. |
| 11 | M&L for PCC 1:1.5:3, A1 (20mm graded aggregate) as in flooring complete all as specified and directed. |
| 12 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Gared A complete all as specified and directed. |
| 13 | M&L for kota stone slab 18-20mm thick polished of uniform colour as in mangers and similar works etc including in raiser and base over and including 15mm thick cement screed 1:4 and jointed with grey cement mixed with pigment to match the shade of the slab complete all as specified and directed. The exposed edges of treads shall be provided of full moulding and all be provided with single piece kota stone complete all as specified and directed. |
| 14 | S&F 1.50mm thick PVC tiles/ sheets, laminated plaincoloured, marbled mosaic or mottled finish, laid with approved synthetic adhesive in vertical surfaces complete all as specified and directed. |
| 15 | Supply and spreading sand under interlocking tiles including watering and consolidation complete all as specified and directed. |
| 16 | M&L for Machine pressed precast conctete interlocking paver block with grey cement and pigment any shape, size and colour confirming to IS 15658-2006of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 17 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soft/loose soil complete all as specified and directed. |
| 18 | Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified and directed. |
| 19 | Returning, filling in, including spreading, leveling, and well ramming in layers n. exc. 25 cm thickness in soil complete all as specified and directed. |
| 20 | Removing excavated material (Soils) to distance of n exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 21 | S&F 15 mm bore dia pipe tubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 22 | S&F 20 mm bore dia pipetubes medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 23 | S&F 1000 Litre capacity Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) three layers hoisted and fixed in position complete all as specified and directed. |
| 24 | S&F non return valves of 20 mm dia of ISI mark pipe to existing /new GI pipes including removing and refixing the same pipe for required fitting to fix the valve etc complete all as specified and directed. |
| 25 | M&L for drilling holes for pipes etc in RCC slab nexc 25mm dia and n exc 150mm depth including fixing of 15mm dia GI nipple with plug complete all as specified and directed. |
| 26 | S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 27 | S&F 15 mm bore float valve of high pressure PTMT with epoxy coated aluminuim rod and high density plastic ball screwed for iron pipe and fixed in tank which situated building including necessary complete all as specified and directed. |
| 28 | M&L for two coat of OBD with preparing old plastered walls surfaces with airless electric sprayers over a coat of primer applied using airless electric spryers over two coat of wall care putty of 1mm thickness prepared and sanded with electrically operated sanding machine. Note : Application to be done through authorised applicator of manufacturer complete all as specified and directed. |
| 29 | M&L for two coats of synthetic enamel paint on steel surfaces over one coat of red oxide or zinc chrome primer, of any description over 10cm width or girth including preparation of new or previously untreated surfaces of steel complete all as specified and directed. |
| 30 | M&L for cement concrete type C2 (1:3:6) (40 mm graded broken stone aggregate) 75 mm thick as in plinth protection and finish even and fair complete all as specified and directed. |
| 31 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar includin gall quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 32 | M&L for Brick work with Fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 33 | Taking down cement plaster of any thickness, raking out joints, hacking for key scrubbing down with water including terrazzo dado or wall finish such as tiles of any description and of any thickness, including for all necessary lowing etc, removal of rubbish of the premises; removal and depositing serviceable materials where directed and leaving the work clear for any type of plastering complete all as specified and directed. |
| 34 | M&L for 15 mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement including in patches complete all as specified and directed. |
| 35 | M&L for preparation of new surface of walls and applying two coat of Oil bound distemper using roller, brushes including in patches over a coat of alkali resistant primer and including 1.50 mm thick cement based wall care putty in two layers with making the surface complete smooth by rubbing etc with minimum 6 hr interval between any two coats complete all as specified and directed. |
| 36 | M&L for coloured glazed ceramic tiles (300 mm x450 mm/300mmx600mm) & 7 mm thick on vertical surfaces such as skirting, dados etc, set and jointed in neat cement slurry over and including 10 mm thick bedding layer/ backing coat in CM 1:4 complete and pointed in white or coloured cement to match complete all as specified and directed. |
| 37 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 38 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed. |
| 39 | Demolition of Ceemnt concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed. |
| 40 | M&L for Reinforced cement concrete (nominal mix) Type B0 1:2:4 (12.5mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed. |
| 41 | M&L for Rough finished surfaces of concrete in Flat, Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed. |
| 42 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 43 | Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings, tube light fittings etc complete and removing all retrieved materials to MES stores for segregation of serviceable /Unserviceable fitting&fixture and also making good disturbed surfaces of wall, floors etc complete all as specified and directed. |
| 44 | M&L in PVC conduit on surface point wiring complete with single core FRLS PVC insulated, unsheathed, multi stranded copper conductor cables 1.5 Sqmm 1100 volts grade, with and incl 1.5 Sqmm FRLS PVC insulated, unsheathed, multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end, complete wiring drawn through & including PVC Casing caping and above (as per conductor run ) medium grade, ISI marked, incl all accessories & fittings, junction boxes, inspection covers etc, with and incl surface mounted PVC sunken box of suitable size for fixing on surface, suitable for fixing of Modular type switches / sockets etc complete all as specified and directed. |
| 45 | S&F Modular Switch 1 way 6 Amps, 1 Module size complete all as specified and directed. |
| 46 | S&F ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all as specified and directed. |
| 47 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 48 | S&F street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and incl two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed. |
| 49 | S&F LED street light luminaire of 35 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection complete all as specified and directed. |
| 50 | S&F in replacement sheet Metal enclosure double shutter type for DB’s 240 Volts Single Pole and Neutral 8 way with 200 Amps rated bus bar complete all as specified and directed. |
| 51 | S&F in replacement SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 52 | S&F in replacement SP 5 to 32 amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 53 | M&L for sub main wiring with 2 run of 6 Sqmm FR, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn drawn through surface mounted casing caping incl all accessories & fittings / junction boxes / inspection covers etc, making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required complete all as specified and directed. |
| 54 | S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical including MCCB, TP, 63 Amp in 4 way VTPN DBs with 200 Amps rated copper bus bar complete all as specified and directed. |
| 55 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 2020 Part-I and connecting to MCBDB’s earth test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 56 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 57 | S&F hook with proper locking arrangment including down rod for haging ceiling fan on truss complete all as specified and directed. |
| 58 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades and deposit in E/M store for declaring BER complete all as specified and directed. |
| 59 | Supplying, laying and testing XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 10 Sqmm 4 core complete all as specified and directed. |
| 60 | M&L for laying GI tubing light grade 40 mm dia with all fittings for cable protection complete all as specified and directed. |
| 61 | M&L for dry sand cusioning for UG cable in trenches including spreading levelling and hand panning and consolidating complete all as specified and directed. |
| 62 | Suppying and laying clay burnt sub class'B' old size brick complete all as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |