| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | M&L for excavation by mechanical means (hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), in all kinds of soils including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated earth within a lead of 50 m complete all as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 5 | Removing excavated material beyond 50 m and upto a total distance of 250 mcomplete all as specified and directed. |
| 6 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 7 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 8 | M&L for hardcore of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick watered and rammed to a true surface complete all as specified and directed. |
| 9 | M&L for cement concrete Type D2 1:4:8 (40mm graded stone aggregrates) as in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. |
| 11 | M&L for formwork to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and directed. |
| 12 | M&L for RCC Type B0 1:2:4 (12.5mm graded stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 13 | M&L for RCC Type B0 1:2:4 (12.5mm graded stone aggregate) nominal mix as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 14 | M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and similiar works etc, all as specified and directed.(Rate incl of use of formwork (straight or curved) complete all as specified and directed. |
| 15 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) incl12mm thick plaster in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 16 | M&L for mild steel TMT CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 17 | M&L for mild steel TMT bars 5 mm dia & over upto 10 mm as in stirrups, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates for ornamental and intricate design, including pintle hinges, stops,hand-made sliding bolts, etc. conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 19 | M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive epoxy paint over a coat of epoxy primer complete all as specified and directed. |
| 20 | Demolition of cement concrete in any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 21 | M&L for 75mm thick cement concrete 1:4:8, Type D-2 (40mm graded stone aggregate) as in sub base of floor/pavement, complete all as specified and directed. |
| 22 | Demolition of stone slabs/tiles of any description or thickness laid, dry and bedded in any mortar complete all as specified and directed. |
| 23 | Dismantling of stone slabs/tiles of any description or thickness laid and bedded in any mortar complete all as specified and directed. |
| 24 | M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm under floors or in foundations spreading and levelling in layers n exc. 25 cm thick including well ramming including watering as required complete all as specified and directed. |
| 25 | M&L for machine pressed precast concrete interlocking paver block any shape, colour and size confirming to IS 15658-2006 of 60mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 26 | Laying only machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, with grey cement and pigment complete all as specified and directed. |
| 27 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement with grey cement and no pigments in floors incl screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 28 | Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing complete all as specified and directed. |
| 29 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 30 | Taking down of existing roof treatment consisting of screed bed plaster tar felts etc and removal of dismantled materials complete all as specified and directed. |
| 31 | S&F in repair of cable trays perforated pre- galvanised sheet of size 100mm*50mm*1.2mm on walls parallel/ perpendicular with necessary studs, nuts, bolts of galvanised steel of suitable length all as per site requirement complete all as specified and directed. |
| 32 | M&L for 10mm thick rendering in CM (1 : 3 ) mixed with water proofing compound on fair faces of brick walls or conc surfaces and finished even & fair complete all as specified and directed. (Note : Water proofing compound shall be measured and paid separately under relevant Item of this schedule) |
| 33 | M&L for cement concrete average 30mm thick type B-0, 1:2:4 (12.5 mm graded aggregate) as in padding on roof slab complete all as specified and as directed. |
| 34 | S&F pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 35 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws complete all as specified and directed. |
| 36 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. using Fe-290 Grade E-165 complete all as specified and directed. |
| 37 | S&F joist, channel, angle,tubular sections or tee sections, fixed independently, w/o connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) as in MS Posts, Plates etc conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 38 | M&L for water proofing treatment in seven course and shall be carried out as follows:- (i) Apply a coat of oil based bituminous primer @ 200 gram/square metre on the prepared surface.(ii) Apply a coat of blow type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area.(iii) Provide and lay 4mm thick APP modified torch applied water proofing compound membrane weighing not less than 4 Kg per square metre reinforced with no woven polyester matt, weighing not less than 160 gm/Sqm having softening point less than 1400C, Longitudinal tensile strength not less than 600 N/50MM, tear strength of 180N(Min), a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15 cm end lap.(iv) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square meter of the surface area.(v) Provide and lay 4mm thick APP modified torch applied water proofing membrane weighing not less than 4 Kg per square metre reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 1400C, Longitudinal tensile strength not less than 650N/50mm, tear strength of 180N (Min) a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15 cm end lap.(vi) Apply a coat blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.20 Kg per square metre of the surface area.(vii) Finishing surface with solar reflective bituminous aluminum paint @ 100 gm/Sqm. |
| 39 | Excavating in post holes (or similar holes) in Soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 40 | M&L for cement concrete Type B-2 1:2:4 (40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 41 | S&F in repair 200mm dia of half round or 220mm width rectangular UPVC heavy duty eaves gutter of pressure rating 6 kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc complete all as specified and directed. |
| 42 | S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 43 | S&F PVC (SWR) bend any radius 110mm bore including necessary fitting like bend, MS clips etc complete all as specified and directed. |
| 44 | S&F point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including cutting chases and suitable size/ cap of sunken box for modular switch and socket and modular white cover plate, flush metal box etc inxl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for one 3 pin 5 Amp socket outlet point controlled by one switch on Independent board and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 45 | All as per item No. 44 here-in-before but for one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 4 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and directed. |
| 46 | S&F switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 00 or equivalent make as per approved list of manufactures. |
| 47 | S&F switch modular type 16/20 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed. Make : Legrand Cat Part No. 5734 10 or equivalent make as per approved list of manufactures. |
| 48 | S&F socket outlet modular type 6A - 2 in 1,with shutter, 2 module, duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 24 or equivalent make as per approved list of manufactures. |
| 49 | S&F socket outlet modular type 6/16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed. Make: Legrand Cat Part No. 5734 71 or equivalent make as per approved list of manufactures. |
| 50 | S&F sheet metal enclosure SPN DB when MCB's to be used 12 way with 240 volts bus bar double door, complete all as specified and as directed.Make : Legrand Cat Part No. 5076 12 or equivalent make as per approved list of manufactures. |
| 51 | S&F sheet metal enclosure SPN DB when MCB's to be used 4 way with 240 volts bus bar double door, complete all as specified and as directed.Make : Legrand Cat Part No. 5078 85N or equivalent make as per approved list of manufactures. |
| 52 | S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 6-32 AMP current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and as directed.Make: Legrand Cat Part No. 4086 72 to 4086 80 or equivalent make as per approved list of manufactures. |
| 53 | S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed.Make : Legrand Cat Part No. 4086 17 or equivalent make as per approved list of manufactures. |
| 54 | S&F MCB 10KA 'C' curve SP 6 to 32 AMP current carrying capacity, 240V, in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-Charge.Make : Legrand Cat Part No. 4085 87 to 4085 95 or equivalent make as per approved list of manufactures. |
| 55 | Material and labour earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounted from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using GI wire 4 mm dia (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as prrotection pipe for GI wire connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil complete all as specified and as directed by Engineer-in-Charge and shown in electricall plate No. 3 of SSR part -1 including testing on completion. |
| 56 | M&L for sub main wiring with four single core 4x6 Sqmm FRLS insulated and sheathed stranded copper conductor cable alongwith earth wire 6 Sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed. (Note: Four runs cable and one number earth wire and suitable FRLS conduit shall be measured together as single unit). |
| 57 | S&F in XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and directed. |
| 58 | S&F factory made three phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCCB and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, IP-43 protection, partly immersed in wall, without MCCB and MCB's including making good distrubbed surfaces with matching colour, complete all as specified and directed.Make- Legrand Cat Part No. 5078 85 or equivalent make as per approved list of manufactures. |
| 59 | S&F MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA complete all as specified and directed.Make : Legrand Cat Part No. 4200 12 or equivalent make as per approved list of manufactures. |
| 60 | S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and directed. |
| 61 | M&L for sub main wiring using proper colour coding 1100 Volts grade with 2 runs of 6 Sqmm (FRLSH) grade PVC insulated unsheathed multistranded copper conductor cable and 1 run of 6 Sqmm (FRLSH) cable as earth continuity wire drawn through and including PVC conduit medium grade not less than 25 mm dia with all conduit accessories concealed in wall/floor including cutting chesses and making good disturbed surface to match with existing surface complete all as specified and directed.Note:- Two runs of 6 Sqmm cable, one run earth wire and one run of PVC conduit pipe with accesories shall be measured as single unit length. |
| 62 | M&L for chemical earthing complete with copper plate size 90x60x5mm burried 3 Mtr length directly into ground and filled with back filling compound conforming to IS 3043-1987 connected to copper strip of size 32x6 mm by means of bolts, nuts and washers made out of brass and connected to test point including necessary excavation earth work and PCC 1:3:6 type C1 chamber 40 mm thick RCC cover complete all as per manufacture's instruction and as recommended in relevant ES code of practice.Note: Rate quoted shall deemed to be inclusive of the cost of copper earthing strip 32x6mm and protection pipe upto 7.5 mtr length with complete earthwork. |
| 63 | M&L for copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. |
| 64 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed. |
| 65 | Supply, Installation, testing and commissioning of 50 KVA isolation transformer 3 phase input voltage 295-465 V and output voltage 400V ,dry type/air cooled protects against electric shocks and works as a safety device with 50 Hz frequency ,overload capability 300% for 10 seconds,150% for 120 seconds, short circuit impedance 4% power factor 0.8,primary to secondary winding isolation 1000V - 3000V ,enclosure protection grade IP22 indoor and digital displaywith quality assurance IEC 60076-1 with minimum maintenance and heat resistance and interconnecting cable complete all as specified and directed. |
| 66 | Supply and laying in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 35 sqmm including necessary thimble, gland, etc complete all as specified and directed. |
| 67 | Supply and laying of 50 mm bore High density polyethylene pipes(HDPE) PN 10 laid in trenches/wall/road crossing for suitable length as per site requirement complete all as specified and directed. |
| 68 | M&L for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of eath plate not less than 1.5mtr below ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C 1 using 20mm raded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinformed with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer nuetral/body/ LT panel etc. and tesing on completion, complete all as specified and directed. Please Enable Macros to View BoQ information |