| Sl. No. | Item Description |
| 1 | Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified and directed by Engineer - in-Charge. |
| 2 | Taking down chowkats with shutters (without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) removing to store all as specified and directed by Engineer - in-Charge. |
| 3 | Taking down shutter of any description exc 1 sqm and n exc 2.00 sqm each complete all as specified and directed by Engineer-in-Charge. |
| 4 | Refixing of shutter in other opening of any description exc 1 sqm and n exc 2.00 sqm each all as specified and directed by Engineer-in-Charge. |
| 5 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall not be paid for separately).Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 6 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall not be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 7 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge.Note : Stainless steel butt hinges and necessary S.S. screws shall be deemed to be inclusive in unit rate quoted of this item. |
| 8 | Providing and fixing 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid decorative type skeleton door shutter open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, mesh etc.; and comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in- Charge.Note : Stainless steel butt hinges and necessary S.S. screws shall be deemed to be inclusive in unit rate quoted of this item. |
| 9 | Providing and fixing factory made uPVC white colour casement (openable) window (outward /inward opening) with hinge system, comprising one outer openable shutter glazed with 6 mm thick selected quality toughened glass and one inner openable shutter fitted with stainless steel wire mesh, both fitted in a panel of single common frame, complete all as specified and as directed. The window shall be manufactured from extruded uPVC profiles having wall thickness of 2.3 mm (±0.2 mm) with multi-chamber hollow sections. Frame size shall be 88 mm × 60 mm, sash 60 mm × 73 mm, vertical T-profile (one vertical member between two shutters to divide the opening into two panels) 74 mm × 88 mm, and glazing bead 35 mm × 20 mm. All profiles shall be mitre cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water. EPDM gasket of 1.2 mm (±0.2 mm) thickness shall be provided. Galvanized steel reinforcement shall be inserted in the profiles as required, viz. frame, sash and T-profile of suitable size matching the respective uPVC profiles. The frame shall be fixed to the wall using 8 mm × 100 mm long fasteners. Hardware shall include zinc alloy white powder coated casement handles, zinc alloy white powder coated butt hinges, mild steel transmission gear with multi-point locking system, and suitable locking handles for inner wire mesh shutters. Necessary accessories, fasteners and all fittings required for proper functioning of all four shutters (two glass outer + two mesh inner) shall be included. The stainless steel wire mesh (SS-304) and 6 mm toughened glass shall be measured and paid along with this item. The work shall be completed in accordance with approved drawings, specifications, and directions of Engineer-in-Charge. Payment shall be made on the basis of net opening area measured in square metres.Note : Rate quoted shall include frame, sash, T-profile, hardware, EPDM gasket, installation, fixing, accessories, SS wire mesh, and 6 mm toughened glass, all complete. |
| 10 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life). |
| 11 | Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-Charge.Note :- (i) The area of each sheet (shutter, sides of cabinet, partition and shelves) shall be measured in sqm for payment.(ii) Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ.(iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 12 | S&F Aluminium handle cast type anodized 125 mm long all as specified and directed by Engineer-in-Charge. |
| 13 | S&F Aluminium anodized barrel tower bolt of extended section and fixed 150 mm long all as specified and directed by Engineer-in-Charge. |
| 14 | S&F 100 mm long butt hinges extruded almiunium alloy with galvanised mild steel hinges pin, anodised and fixed all as specified and directed by Engineer-in-Charge. |
| 15 | S&F 200 mm long Aluminium anodized barrel tower bolt of extended section and fixed all as specified and directed by Engineer-in-Charge. |
| 16 | S&F in repair 200mm long Aluminium anodized barrel tower bolt of extended section and fixed 200 mm long all as specified and directed by Engineer-in-Charge. |
| 17 | S&F 150 mm long Aluminium handle cast type anodized all as specified and directed by Engineer-in-Charge. |
| 18 | S&F in repair 150 mm long Aluminium handle cast type anodized all as specified and directed by Engineer-in-Charge. |
| 19 | S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as directed. |
| 20 | S&F in repair 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as directed. |
| 21 | S&F continous (Piano)type hinges mild steel bright finish or lectro galvanised with wide of flaps 30mm complete all as spd and directed. |
| 22 | S&F magnet ball catcher for cupboard shutter, complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F 125 mm size hasp and staple,aluminium anodished,including bolt to hinge plate and fixed with screws,complete all as directed. |
| 24 | S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge. |
| 25 | Demolition of cement concrete ( un-reinforced) of any description in roofs, floors(other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified. |
| 26 | Dismantling brick terracing tiles single layer from roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Demolition/taking out of old roof treatment film (any type in any position), mud from roofs, any thickness, including removing / cutting uprooting grass,vegetations and roots of small plants etc on roof and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge |
| 28 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth wihout using extra cement complete all as specified. (Minimum thickness of concrete should not be less than 25mm at any point.Note : Waterproofing compound should be measured and paid seperately. |
| 29 | Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as speccified.Make : Fosroc/Sika/Choksey/Bostik/STP/Asian Paints/Berger Paints. |
| 30 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 31 | M&L PCC 1:2:4, type B-1 , using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed. |
| 32 | Demolation of ashlar facings, dressed stone work, stone slabs or tiles from paving and precast concrete blocks and articles all as specified.& directed by Engineer -in-charge.. |
| 33 | Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc. |
| 34 | Material and labour for plastering 10mm thick with ready mix cement plaster material on concrete surfaces of ceiling, finished fair and even complete all as specified and as directed. |
| 35 | Material and labour for plastering 12mm thick with ready mix cement plaster material on internal surface of Brick walls or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 36 | Material and labour for plastering 15mm thick with ready mix cement plaster material on external surface of Brick walls/chajja/fins or concrete surfaces, finished even and fair complete all as specified and as directed. |
| 37 | M&L for Treating apparent visible efflorescenceby first cleaning using hard wire brush and all crystal deposits to be removed. The bricks shall then be cleaned using soft brush of powdery crystals removed. Then make a 1 to 4 solution of vinegar and water (1 part vinegar to 4 part water) and apply it to the afflorescence affected area using a nylon brush. Allow the vinegar/water solution to sit on the serface of the affected area for 15 minutes, but do not allow the solution to dry, Rinse the area with clean water using low pressure jet. Two cycle of cleaning using vinegar water solutions to be repeated complete all as specified and as directed.Make : Sika India Pvt Ltd or equivalent. |
| 38 | M&L for the joints of briks to cleaned shall be pointed using cement putty made at site using sika latex/SBR polymer diluted at retio of 1:4 with water. The solution to made shall be used to mix with cement to make a putty consistency paste. The cement putty shall be then work out in the joints complete all as specified and as directed.Make : Sika India Pvt Ltd or equivalent. |
| 39 | M&L for the bricks so pointed shall be cleaned for all dust are deposit using brush. A undiluted single component acrylic polymer - Sika Raintite to be used to prime the brick surface. The primer while being tacky the first coat of water proofing coating is done, Second coat is applied after a time interval of 4-6 hrs after the first has dried. The water proofing coating shall be two component polymer modified cementious coating - Sika Top Seal - 107, having a thickness of 1.5 mm in 2 coat. The material to be factory batched and ready to use. The two component shall be mixed using low speed drill having a RPM 350-450 and fitted with a paddle.The mixing to be done for 3-4 minutes to give a brushable consistency mix. The coating shall be done using 100-150 mm wide brush. It is to be take care that material while being used is agitated every 3-5 minutes to avoid powder part getting settled. The water proofing coating shall have below properties Tensile strength- 4.56 N/mm2 after 14 days exposure (According to ASTM D 2370 ) Bond Strength 2.0 N/mm2 at +27degree C (Failure in substrate). After application of second coat and while the material is still wet, coarse sand is sprinkled over the coating so as to ensure proper machanical key is provided for subsequent plaster complete all as specified and as directed.Make : Sika India Pvt Ltd or equivalent. |
| 40 | M&L for plastering 15mm thick over the treated surface in CM 1:4 cement sand plaster added with acrylic polymer Sika Plastocrete Plus @ 3% by weight of cement finished even & smooth without using extra cement all as specified and directed by Engineer-in-charge.Make : Sika India Pvt Ltd or equivalent. |
| 41 | M&L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified. |
| 42 | M&L for preparation of surfaces and applying one coats of cement base paint on old treated surface of wall etc complete all as specified and directed. |
| 43 | M&L for preparation of old surfaces and applying one coats of oil bound distemper with roller on old treated surface of wall etc complete all as specified and directed. |
| 44 | M&L for preparation to old decorated, plastered or unplastered surfaces of ceiling, by brooming down, scraping down smoke spots, moulds, mossand efflorescent salts etc. and applying one coat of white (lime) wash including cornices pilasters etc complete all as specified and as directed. |
| 45 | M&L for preparation of newly plastered surfaces and applying two coats of cement base paint complete all as specified and directed. |
| 46 | M&L for preparation of surfaces and applying two coats of oil bound distemper with roller on newly plastered surfaces of wall etc complete all as specified and directed. |
| 47 | M&L for preparation of newly plastered surfaces of ceiling and applying two coat of white (lime) wash including cornices pilasters etc complete all as specified and as directed. |
| 48 | M&L for preparation to old painted surface of steel over 10cm width or girth of any description & applying one coat of synthetic enamel paint by mechanical means complete all as specified and as directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises. |
| 50 | M&L machine cut kota stone slab flooring 16-18mm thick in single piece over cement screed base laid and jointed with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6) all as directed by Engineer-in-Charge. |
| 51 | M&L for kota stone slab flooring 16-18mm thick in single piece in riser of steps,skirting,dado and pillar laid and jointed with grey cement mixed with pgment to match the shade of the slab including rubbing and polishing complete inculding screed bed or bedding layer of mortar 15 mm thick CM (1:6) all as directed by Engineer-in-Charge. |
| 52 | M&L for Granite (of any type) tiles 16mm to 18mm thick, machine-cut, fixed all around window openings (including sill, jambs and lintel), bedded and jointed with grey cement slurry and pointed with white cement mixed with approved pigment to match the shade of granite; including edge rounding/chamfering as required, and machine polishing to a smooth finish. Granite to be laid on a 15mm thick screed bed or bedding layer in cement mortar (1:6), complete all as specified. |
| 53 | M&L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge. |
| 54 | M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular ) joint free tiles area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqmand shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. |
| 55 | M&L Non skid ceramic coloured /printed tiles 7 to 8 mm thick( square /rectangular ) joint free tiles area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqmand shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade over and incl 15 mm thick rendering in CM 1:4 complete all as specified and directed by Engr in Charge. |
| 56 | M&L 25 mm thick Cement Concrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer, including necessary demolition complete all as specified and directed by Engineer - in – Charge . |
| 57 | Demolition of cement concrete ( un re-inforced) of any description in ground floor and similar suspended work complete all as specified and directed by Engineer - in - Charge. |
| 58 | M&L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. |
| 59 | S&F machine pressed precast concrete interlocking paver block with grey cement & no pigment, any shape and size confirming to IS 15658-2006 of 80mm thick M-40 grade including and over 25mm thick sand cushion. |
| 60 | S&F in repairs stainless steel kitchen sink 1.00mm thick with drainage board of overall size 915x460mm and bowl size 410x330x160mm with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe including brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as directed. |
| 61 | S&F in repairs stainless steel plate rack of size 900x775x250mm of 1mm thick stainless steel of 1st Quality all as specified and directed by Engineer-in-Charge. |
| 62 | S&F 25 mm dia S.S drapery curtain rod with decoative end knobs complete with brackate and fixed to walls complete all as specified and directed by Engineer-in-Charge. |
| 63 | S&F 600mm x 450mm beveled edge mirror of selected quality glass on 6mm thick commercial plywood and fixed wooden plugs with chromium plated brass screw and cup washes fixed in repaire. |
| 64 | S&F in repair bib taps long body, 15mm bore dia, fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified . |
| 65 | S&F in repair soap dish brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge |
| 66 | S&F brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges incldg brackets complete all as specified and directed by Engineer - in - Charge . |
| 67 | S&F in repair PVC connection both side brass unions internal for size 15mm dia and 600mm long all as specified and directed by Engineer-in-Charge. |
| 68 | Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store |
| 69 | Supply & fixing 3 layer PPR CONCEALED PIPES of size 20mm SDR 7.4 (PN16) UV stabilised having thermal stability for hot and cold water supply incl. all PPR plain and brass threaded polypropylene random fittins fixed to walls complete all as specified. |
| 70 | Taking down eves and gutter and rain water of any size all as specified and directed by Engineer - in - Charge . |
| 71 | Supply & fixing 100mm bore UPVC (SWR) pipes including necessary fittings like band ,tee,coupler,floor trap etc. single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC clampps and laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge. |
| 72 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for. |
| 73 | M&L RCC 1:1½:3, (nominal mix), Type A-1, using 20mm graded aggregates as in chajjas, fins, fascias,shelves , louvers, parapets and railing etc and the like including necessary formworks all as specified and directed by Engineer - in - Charge. |
| 74 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. |
| 75 | Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed. |
| 76 | M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 77 | M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified. |
| 78 | S&F Aluminium door stopper of 140mm or more all as specified and directed by Engineer-in-Charge. |
| 79 | S&F fibre sheet 2mm thick reinforced translucent plain sheeting with drilling punching corrougation fixed with coach screw and washer etc in angle wall and other necessary item, complete all as specified |
| 80 | S&F framed work such as grills, cooler stand ,ladder grating and sun shed etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 all as specified . |
| 81 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 82 | Shortcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix(minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characteristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound/weak concrete material 25mm average thickness from slabs, beams, columns etc with manual chisel and/or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@6 sqm/ltr at DFT of 100 microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.Note : After completion of shorcreting the splash of cement on wall to be cleaned completely. |
| 83 | M&L for Shotcreting 25MM thick in RCC Facias, beams n.exc 450 in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 50mm average thickness from RCC Facias, beams with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications including fixing hard drawn steel wire fabric not exceeding 4 Kg / Sqm cut to lengths, bent to shape required and disposal of debries for all lead and lifts complete all as specified and directed by Engineer-in-Charge |
| 84 | S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and typing with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement all as specified & directed by Engineering-in-Charge. |
| 85 | M&L for providing and injecting chemical emulsion for post constructional antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.50 Ltrs per Sqm of the vertical surfaces of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and directed. Note : Quantity will be measured perimeter of wall x depth of penetration. |
| 86 | Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate. |
| 87 | Taking down unserviceable main switches and MCB distribution boards single phase complete all as specified and directed. |
| 88 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, with Chromium plated brass screws & washers fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ). Note :- Where ever it is not feasible to cable drawn through PVC conduit (for ceiling fan point only) due to blocked, casing caping ISI marked shall be provided by contractor without any extra cost, cost for the same shall deemed to be included in the quoted unit rate. |
| 89 | All as per Item No 88 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ.) |
| 90 | All as per Item No 88 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ). |
| 91 | All as per Item No 88 above here in before but for One light point controlled by two 2-way switches of 5 amps (switch shall be measured and paid separately under appropriate item of BOQ). |
| 92 | Description all as per item No 88 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ). |
| 93 | Supply & Fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 94 | Supply & Fixing modular switch 5/6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 95 | Supply & Fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 96 | Supply & Fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 97 | Supply & Fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 98 | Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric lamp 9 Watt with backalite 20mm back plate complete all as specified & directed, . |
| 99 | M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. |
| 100 | S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. |
| 101 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed. |
| 102 | S & F of RCCBs suitable for 240 volts AC supply, double pole 25A, 30mA with earth leakage protection all as specified and directed. |
| 103 | S & F LED study lamp wall mounted holder type with 3 watt bulb, model & design to be finalized by Engr -in-charge complete all as specified and directed. |
| 104 | Supply and fixing Wall mounting fans complete with 3 blades and accessories, 230 V, 400 mm sweep. Five star rated with brushless direct current motor (BLDC) as specified and recommended by manufacturer all as specified and directed by Engineer in Charge Make : Bajaj/Orient/Crompton, Havells and its equivalent. |
| 105 | S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 12 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.. |
| 106 | S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.. |
| 107 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. |
| 108 | Supply and fixing MCCB TPN (4 pole) 63 Amps 415 Volts of braking capacity 16 KA including complete taking down old unserviceable one and making necessary connections as existing IS with CTC solutions complete all as specified and directed. |
| 109 | S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 110 | S & F LED backup/Rechargeable tube light polycarbonate housing 1x18/20 watt, appx 4 feet long module complete all as specified and directed |
| 111 | S&F for WEE Plus LED building security light luminaire of capacity 35 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65/66 complete all as specified and directed by Engr-in-Charge |
| 112 | Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. |
| 113 | M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 114 | M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 6 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified.Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 115 | Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type with remote, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified.Note :- (i) Down rod must be 2.5\\" in lieu of standard rod with ceiling fan (ii) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account(iii) Fasteners hook heavy duty and hook length is not more than 12\\"capacity for ceiling fan to be fixed in the ceiling, including fasteners hooks and suitable tools cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account all as specified.(iv) old US ceiling fan to be deposited in MES yard. |
| 116 | Earthing complete with galvanised steel earth plate electroe 60 cmx60cm6mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connectedto and including galvanized earth lead GI wire of size 4.0 mm by means of GI bolt/snuts/washers, protected by 40mm bore GI light grade pipe from earth plate & upto 3m long pole fixed with 2 clamp made from mild steel flat iron 32x6mm bolts, nuts, washer etc. earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around buttom and top of earth plate 20mm dia GI Medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame PCC 1:3:6 type C1 using 20mm graded stone aggregate as in earthing pit including necessary excavation & earth work all as specified & shown on electrical plate No. 3 of SSR Part-I.Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner (ii) earthing for Lightning protection is also included in the above item. |
| 117 | Dismantling and taking down of existing solar heating system along with connected items viz Flat collector plate, master solar plate, hot water tank, pipelines all types, valves , including iron stand and other items and refixing the same with necessary repair to the solar heating system items and leakage of pipelines , replacement of hot pipe insulation and making the solar system functional all as directed by Engr-in-Charge. Note : 1. Replacement of heating element of 2 KW, thermostat and replacement of tank deemed to be included in the unit rate quoted by contractor. 2. Any leakage of incoming and outgoing pipeline connected to solar system to be repaired or if necessary replacement upto 20 Mtr of 20 mm GI pipes deemed to be included in the unit rate quoted by contractor. |
| 118 | Supply and fixing MCCB TPN ( 4 pole) 100 Amps 415 Volts of braking capacity 16 KA complete taking down old unserviceable one and making necessary connections as existing ls with CTC solutions complete all as specified and directed. |
| 119 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and as directed by Engineer-in-charge. |
| 120 | M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 80mm GI pipe complete all as specified and directed. |
| 121 | Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site. |
| 122 | Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site |
| 123 | Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. |
| 124 | Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 77 mm minimum inside dia 63 mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 25 sqmm 4 core complete all as directed. |
| 125 | Supply and fix light grade 50mm GI pipe fix complete to Wall , Poles etc with suitable clamp for protection of cable complete all as directed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail