| 1 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 3 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and directed. |
| 4 | Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed. |
| 5 | Demolition of cement concrete unreinforced of any description and in any position not specifically provided and removal of rubbish beyond MOD land complete all as specified and directed. |
| 6 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness, below or above ground level, complete all as specified and as directed. |
| 7 | Demolition of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed. |
| 8 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, rubbish off the premises complete all as specified and directed |
| 9 | Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 10 | Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed. |
| 11 | M&L for preparation of new plastered surface of wall by applying three coats of white wash, complete all as specified & directed |
| 12 | M&L for preparation of new plastered surface of Ceiling by applying three coats of white wash, complete all as specified & directed |
| 13 | M&L for preparation of new plastered surface of external wall and chajjas, making surface smooth using sand paper, priming the surface with alkali resistance primer paint for external surface, applying two coats of cement base paint including curing complete all as specified & directed. |
| 14 | Preparation of new plastered or unplastered surfaces of walls and applying 2mm thick wall care putty, making the surface smooth & applying two coats of oil emulsion paint over a coat of priming paint, complete all as specified and directed. |
| 15 | M&L for preparation of new plastered surfaces of external wall and chajjas making the surface smooth with sand paper by applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface, complete all as specified and as directed. |
| 16 | Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball including dismanting of water tanks of capacity exc 250 ltrs but not exc 500 ltrs and removing to store, complete all as specified and directed. |
| 17 | S&F in repair 20 mm size gun metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixed cast copper chromium plated fancy type alloy ISI marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed. |
| 18 | S&F 110mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 19 | S&F in repair 75mm bore dia PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls with clamps, complete all as specified and directed. |
| 20 | S&F in repair 110mm bore dia PVC (SWR) reducers, complete all as specified and directed. |
| 21 | S&F in repair 110mm bore dia PVC (SWR) branch piece, single (single Y) equal or unequal with parrallel branches fitted with oval access doors, complete all as specified and directed. |
| 22 | S&F in repair 110mm bore dia PVC (SWR) bends,any radius (larger bore measured), complete all as specified and directed. |
| 23 | S&F in repair 75mm bore dia PVC (SWR) bends, complete all as specified and directed. |
| 24 | S&F in repair PVC (SWR) 75mm bore Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors, complete all as specified and directed. |
| 25 | S&F in repair 75mm bore pipe PVC (SWR) vent cowl, complete all as specified and directed. |
| 26 | S&F in PVC floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with or without hole for waste pipe complete all as specified and directed. |
| 27 | Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and as directed. |
| 28 | PCC type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed. |
| 29 | 5mm thick rendering on concrete surface of ceiling, chajjas etc. in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 30 | 10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 31 | M&L for rendering 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete if required and making surface in true line, true shape and finishing the surface smooth without using extra cement complete all as specified and directed. |
| 32 | 15mm thick rendering cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately. |
| 33 | M&L green marble work 12mm to 15mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 15mm thick cement mortar (1:4) including cutting moulding, polishing and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including round chamfering to the edges and dismantling floor hearth or wall tiling including cement mortal bedding & removing rubbish off the premises of MoD land, complete all as specified and directed. |
| 34 | M&L 15-18mm thick machine cut kota stone slab flooring as in treds of steps (one piece) over 15mm thick screed bed laid in cement mortar 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and Round chamfering to the edges , complete all as specified and directed. |
| 35 | M&L 15-18mm thick machine cut kota stone slab as in riser of steps, skirting, dado and pillar (one piece) over 10mm thick screed rendering laid in cement mortar 1:4 and jointed, complete all as specified and directed. |
| 36 | Supply only liquid water proofing compound, complete all as specified and directed. |
| 37 | M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in seismic, cills, steps, plinth and other similar bands, broken Chajjas and roof protection, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed. |
| 38 | M&L for PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof mixed with microfilament microfiber (crack control fiber) mixed with URP/SBR including WPC as per manufacturer's instruction, surface finished even and smooth without using extra cement, complete all as specified and directed. Note: WPC & URP/SBR shall be measured and paid for separately. |
| 39 | 100mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as in sub-base of floors, sub-bases, floors, pavings etc, complete all as specified and directed. |
| 40 | 60mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-35 grade, complete all as specified and directed. |
| 41 | M&L for PCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, benching, rounded or chamfered on edges of interlocking tiles, complete all as specified and directed |
| 42 | M&L for precast RCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs for septic tanks, manholes and the like and similar articles including necessary moulds/ forrmwork etc set and jointed in CM 1:6, complete all as specified and directed |
| 43 | M&L 20mm thick cement plaster in cement mortar 1:4 on brick or concrete surface finished even and smooth mixed with liquid water proofing compound as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified and directed.Note : WPC shall be measured separately. |
| 44 | M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid ploymersand reinfoecing acrylic fibers with sun reflective index(SRI) of 100-110 having maximumelongation of 350% tensile strength od 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 grm/sqm and pastinf it properly with overlaping of 50mm and allow it to dry, Apply second coat of undiluted coat @ 0.45 ltr/ Sqm . Apply third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacture of authorised applicator complete all as specified and directed. Please Enable Macros to View BoQ information |
| 45 | M&L for preparation of surfaces and apply first coat fiber reinforced elastomatic liquid water proofing membrane formulated with PU hybrid ploymersand reinfoecing acrylic fibers with sun reflective index(SRI) of 100-110 having maximumelongation of 350% tensile strength od 2.9 Mpa and shall have crack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic presure and reduce surface temprerature upto 10 degree celsius with 33% ditution of priming coat. Laying of fiber mesh of 0.3mm thickness weave in leno pattern having 45 grm/sqm and pastinf it properly with overlaping of 50mm and allow it to dry, Apply second coat of undiluted coat @ 0.45 ltr/ Sqm . Apply third and final coat undiluted @ 0.45 ltr/sqm complete application to be done by the manufacture of authorised applicator complete all as specified and directed. Please Enable Macros to View BoQ information |