| 1 | I) FIRE PUMPS & ACCESSORIESSupply, Installation, Testing and Commissioning of Electric driven Fire pump suitable for automatic operation and consisting of following: complete in all respect as required.a) Horizontal, back pullout pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 900 lpm at 55 m. head conforming to IS standards.b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set.d) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement. | I) FIRE PUMPS & ACCESSORIESSupply, Installation, Testing and Commissioning of Electric driven Fire pump suitable for automatic operation and consisting of following: complete in all respect as required.a) Horizontal, back pullout pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 900 lpm at 55 m. head conforming to IS standards.b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. c) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set.d) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement. |
| 2 | Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumps | Supplying, Installation, Testing and Commissioning of Control Panel suitable for automatic operation of fire fighting pumps consisting(a) Necessary cabling, wiring, earthing from panel to individual equipment shall be included in the quoted price.(b) Facility for more selections i.e auto or manual.(c) Protection failure and control cabling.(d) interlocking of pressure switch with pumps |
| 3 | Supply, Installation, Testing and Commissioning of 25 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 310 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required. | Supply, Installation, Testing and Commissioning of 25 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 310 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required. |
| 4 | Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be double pole single throw type suitable for single phase supply with diaphragm. Aluminum Enclosure with IP 66 protection as required. | Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be double pole single throw type suitable for single phase supply with diaphragm. Aluminum Enclosure with IP 66 protection as required. |
| 5 | Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M S Pipes Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. | Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M S Pipes Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. |
| 6 | Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. | Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. |
| 7 | Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6) | Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6) |
| 8 | Supply, installation, testing and commissioning of First Aid Hose Reel equipment conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, Rubber hose reel tubing as per IS: 444 of 25 mm dia x 60 mtr. long, painting, Manual fix type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority | Supply, installation, testing and commissioning of First Aid Hose Reel equipment conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, Rubber hose reel tubing as per IS: 444 of 25 mm dia x 60 mtr. long, painting, Manual fix type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority |
| 9 | Supply, installation, testing and commissioning of SS Ball Valve. a) 25mm dia | Supply, installation, testing and commissioning of SS Ball Valve. a) 25mm dia |
| 10 | Supply, installation, testing and commissioning of Fire Pipe Support Size100mm | Supply, installation, testing and commissioning of Fire Pipe Support Size100mm |
| 11 | Supply, installation, testing and commissioning of Cast lron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required. | Supply, installation, testing and commissioning of Cast lron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required. |
| 12 | Supply of Fire Alarm System with hooter,mcp with wiring. | Supply of Fire Alarm System with hooter,mcp with wiring. |
| 13 | Core cuting/ close off core cutting water proofing Charges | Core cuting/ close off core cutting water proofing Charges |
| 14 | 25 mm Air Release Valve | 25 mm Air Release Valve |
| 15 | water tank 5000 PVC ltr | water tank 5000 PVC ltr |
| 16 | 75 mm UPVC Pipe Connection for Water Tank | 75 mm UPVC Pipe Connection for Water Tank |
| 17 | 50 mm UPVC Ball Valve | 50 mm UPVC Ball Valve |
| 18 | cable for pump supply 4 sq mm 4 core | cable for pump supply 4 sq mm 4 core |
| 19 | Design, supply & installation of safety signage made of redium light Such as EXIT EMERGENCY EXIT. Do not use lift etc. | Design, supply & installation of safety signage made of redium light Such as EXIT EMERGENCY EXIT. Do not use lift etc. |
| 20 | NOC GOVERNMENT LEGAL FEES ( Getting Approval/NOC of Fire protection system from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority. | NOC GOVERNMENT LEGAL FEES ( Getting Approval/NOC of Fire protection system from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority. |
| 21 | Providing and fixing carbon dioxide type fire ext 4.5KG capacity ofapproved make with ISI mark | Providing and fixing carbon dioxide type fire ext 4.5KG capacity ofapproved make with ISI mark |
| 22 | Providing and fixing ABC type fire extinguishers of 6kg/Capacity of approved make with ISI mark. | Providing and fixing ABC type fire extinguishers of 6kg/Capacity of approved make with ISI mark. |