| 1 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/l. |
| 2 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of un serviceable materials with all leads all complete as per direction of E/l. |
| 3 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 4 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 5 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 6 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 7 | Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. |
| 8 | Taking down chowkhat in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l. |
| 9 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per do ---- do ---- e/i. |
| 10 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 11 | Providing and laying in position cement concete of soecified grade excluding the cost of centering and shuttering - All work up tp plinth level 1:2:4 (1 cement :2 coarse sand (Zone -III) :4 graded stone aggregrate 20 mm normial size) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stoneaggregate 20 mm nominal size) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal |
| 15 | Providing Tor steel reinforcement of 8 mm, 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. {only valid for TATA (Tiscon), SAIL, JSPL, Electrosteels Ltd. Bokaro and Vizag (RINL)} |
| 16 | 8 mm dia |
| 17 | 10 mm dia |
| 18 | 12 mm to 20 mm dia |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 20 | Foundations, footings, bases for columns, etc for mass concrete. |
| 21 | Columns, Pillars, Piers, abutments, Posts and struts |
| 22 | Suspended floors, roof , landings , balconies and access platform |
| 23 | Tie beam |
| 24 | providing designation 75 B brick work in C M ('1 :6 ) in foundation and Plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing. taxes and royalty all complete as per building specification and direction of E/I. |
| 25 | Providing designation 75 B brick work in C.M.(1 :6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 26 | Supplying,frtting and fixing M.S. grill made of 20x6cmm M.S. flat as per approved design and drawing, properly fabrlcated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. |
| 27 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners,all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm |
| 28 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 29 | Providing and laying, Doublecharge vitrified floor tiles in different sizes (thickness to be specified by lhe manufacturer) with water absorption less than 0.08% and conforming to lS 15622/ISO 13009 of approved make in all cotours and shades, laid on 20mm thick cement mortar 1 4 (1 cement:4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of tile 600x600 mm |
| 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 31 | Providing and laying 25mm. thick kotah stone slab flooring of approved size, texture and colour over 19 mm thick base of lime morter (1:1:1) ( Lime putty : surkhi: coarse sand ) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. (iv) 600 X 600 mm size |
| 32 | Providing and laying 25mm. thick kotah stone riser of steps, skirting and pillers of approved size, texture and colour over 12 mm thick cement morter (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to granolithic finish with approved quailty of carborandum stone including cost of curring, taxes and royalty all complete as per building specification direction of E/I. |
| 33 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete as per building specification and direciton of E/l.With commercial grade colour 15x15 cm tiles. |
| 34 | Toilet/Kitchen Water proofing: 1) Surface preparation by grinding machine, cleaning , crack fillingetc. complete Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry |
| 35 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 36 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I. |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smoothcomplete |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade,New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg /10sqm) |
| 39 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 40 | Painting with synthetic enamel paint of approved brand and make over a coat of red lead primer over new steel surface all complete as per building specification and direction of E/I. |
| 41 | Providing two coats of snowcem of approved shed and make over a coat of primer surface do all complete as per building specification and direction of E/I. |
| 42 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse send : 6 graded stone aggregate 20 mm nominal size ) over 75 mm thick bed of dry brick ballast 40 mm nominal size,wall rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the |
| 43 | Water proofing for Old or new roof slab :- (a) surface prepration :- P & L water proofing treament (b) 1st Coat :- Apply 1st coat of two component acrylic modified ……. ( c) 2nd Coat :- To apply the 2nd coat of two component (d) Protection of treated surface with PCC 25/50 mm th (1:1.5:3) .. |
| 44 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 45 | Labour for cutting old mosaic or precast terrazo tiles including cost of removing dirt, rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curring, taxes and royalty all complete as per building specification and direction of E/I. |
| 46 | Carriage of Materials |
| 47 | Stone chips |
| 48 | Bricks |
| 49 | Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings,C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I.580 mm long With 10 ltr low level PVC cistern |
| 50 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 51 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 52 | Providing and fixing C.P. brass bib cock of approved quality confirming toIS:8931 |
| 53 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 893115 mm nominal bore |
| 54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,Single socketed pipes. |
| 55 | 75 mm diameter |
| 56 | 110 mm diameter |
| 57 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming toIS : 5382, leaving 10 mm gap for thermal expansion. |
| 58 | 110 mm |
| 59 | Single tee with door 110x110x110 mm |
| 60 | Bend 87.5° |
| 61 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 62 | 75mm dia |
| 63 | 110 mm dia |
| 64 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall |
| 65 | 25 mm nominal outer dia pipes |
| 66 | 32 mm nominal outer dia pipes |
| 67 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc. |
| 68 | 20 mm nominal outer dia pipes |
| 69 | 25 mm nominal outer dia pipes |
| 70 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 71 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 72 | Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation and refilling all complete as per specification and direction of E/l. |
| 73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making goodthe walls wherever required :470x420 mm bowl depth 178 mm |
| 74 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. |
| 75 | From 0.00 M to 50.00 M below G.L. |
| 76 | From 51.0 M to 125.00 M below G.L. |
| 77 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia |
| 78 | Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \\"V\\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer in-charge |
| 79 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia |
| 80 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp |
| 81 | Supplying Submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP |
| 82 | Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I. |
| 83 | Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I. |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes& fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as perdirection of Engineer in Charge. 32 mm dia nominal dia pipe |
| 85 | Rewiring for light point / fanpoint /exhaust fan point with1.5 sq. mm FR PVC insulated copper conductor single core do ----- do ------ e/i.Group - B |
| 86 | Supplying and drawing following size of FR PVC insulated copper conductor single core cable do ------ do ------ E/I. |
| 87 | 3 x 1.5 sq. mm |
| 88 | 3 x 2.5 sq. mm |
| 89 | 3 x 6 sq. mm |
| 90 | Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connection do ---- do ---- e/i. |
| 91 | 5/6 amps. One way switch |
| 92 | 15/16 amps.one way switch |
| 93 | 3 pin 5/6 amps, socket outlet |
| 94 | 6 pin 15/16 amps, socket outlet |
| 95 | Supplying and fixing stepped type electronic fan regulator on existing modular plate & switch box do ------- do ----- e/i. |
| 96 | Supplying and fixing following size / modules, G.I. box along with modular base & cover do ------ do ------ e/i. |
| 97 | 1 or 2 module (78 mm x 78 mm x 45 mm) |
| 98 | 6 module (78 mm x 205 mm x 50 mm) |
| 99 | Supplying and fixing Batten / Angle holder including connection etc. as required. |
| 100 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"B\\" series MCB suitable for inductive load of following do ------- do ------ e/i. |
| 101 | 6/32 amps, single pole, \\"B\\" series |
| 102 | 6/32 amps, TPN |
| 103 | 40 amps, TPN |
| 104 | S.I.T.C. of following rating surface mounted LED tube light fitting sutaible for 230V 50 Hz, single phase do ------- do ------ e/i.10/12W LED Tube light |
| 105 | S.I.T.C. of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring sutaible for 230V 50 Hz, single phase do ------- do ------ e/i.1200 mm (48\\") Ceiling fan |
| 106 | Supplying of 12\\" (300 mm) metal exhaust fan. For Kitchen |
| 107 | Supplying of 9'' (230 mm) metal exhaust fan. For Toilet |
| 108 | Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l. |
| 109 | Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B) |
| 110 | Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume). |
| 111 | Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 112 | Add 18% GST (In Basic Rate must fill 0.18) |
| 113 | Add 1% Labour cess (In Basic Rate must fill 0.01) Please Enable Macros to View BoQ information |