| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8125/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR/ IMPROVEMENT OF INTERNAL ELECTRIFICATION, SUB MAIN WIRING, EARTHING, BLDG SECURITY LIGHTS AND OTHER CONNECTED ACCESSORIES AT MH/MD AREA UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulators etc and making good the disturbed surface of walls, floors etc. complete all as specified and as directed. |
| 3 | Taking down existing sub main wiring of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc. |
| 4 | M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLSH) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed/surface type on stone / brick, masonry walls, roof etc including new CI/MS sunken box of required size and all as directed & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases making good the disturbed surfaces during cutting/running chases, pinning in to match with the existing specification, complete all as specified and as directed at site. |
| 5 | All as per item no.03 but One 3 pin 5/6 Amps switch socket outlet on independent board complete all as specified and as directed |
| 6 | All as per item no.03 but One 3 pin 5/6 Amps switch socket outlet on same board complete all as specified and as directed |
| 7 | All as per item no.03 but for One 3 pin 15 / 16 Amps switch socket outlet point on independent board with 4 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core multi stand flexible cable and 4 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and as directed |
| 8 | M & L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLSH unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/brick, masonry walls, roof etc including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLSH unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site. |
| 9 | All as per Item No.7 above but one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed at site. |
| 10 | All as per Item No.7 above but for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches complete all as specified and as directed at site. |
| 11 | All as per item no:7 but for One 3 pin 15 / 16 Amps modular switch socket outlet point on independent board with 4 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core multi stand flexible cable and 4 sqmm PVC (FRLSH) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and as directed at site. |
| 12 | S&F switch piano flush type single pole one way 5/6 Amps complete all as specified and as directed at site. |
| 13 | S&F in repair switch piano flush type single pole one way 5/6 Amps complete all as specified and as directed at site. |
| 14 | S&F switch socket combination flush type 5/6 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and as directed at site. |
| 15 | S&F in repair switch socket combination flush type 5/6 Amps Multipurpose 2 in 1, 3 pin/5 pin with porcelain base complete all as specified and as directed at site. |
| 16 | S&F switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and as directed at site. |
| 17 | S&F in repair switch socket combination 2 in 1 flush type universal 3 pin 5 & 15 Amps complete all as specified and as directed at site. |
| 18 | S&F in repair lamp holder insulated body with back plate suitable for bittern fittings complete all as specified and as directed at site. |
| 19 | S&F in repair Ceiling rose surface Bakelite 65 x 50 mm 2/3 terminals complete all as specified and as directed at site. |
| 20 | S&F in repair Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and as directed at site. |
| 21 | S&F in repair Bell push, flush type, 5 Amps complete all as specified and as directed at site. |
| 22 | S&F Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed. |
| 23 | S&F in repair Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed. |
| 24 | S&F Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed. |
| 25 | S&F in repair Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed. |
| 26 | S&F Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. |
| 27 | S&F in repair Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. |
| 28 | S&F Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 29 | S&F in repair Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 30 | S&F in repair modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed. |
| 31 | S&F in repair modular bell push 6 Amps 1 module complete all as specified and as directed. |
| 32 | S&F in repair Factory made Prewired TPN 4 ways distribution board in sheet steel enclosure vertical double door with suitable rated bus bar, 240 Volts suitable for housing TPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 33 | S&F in repair Factory made SPN 8 ways distribution board in sheet steel enclosure vertical double door with suitable rated bus bar, 240 Volts suitable for housing SPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 34 | S&F in repair Factory made SPN 4 ways distribution board in sheet steel enclosure vertical double door with suitable rated bus bar, 240 Volts suitable for housing SPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 35 | S&F in repair MCB, Four pole, 240 volts, 63 Amps 10 KA C curve complete all as specified and as directed. |
| 36 | Supply and fix MCB SPN 32 Amp, 240 volts 50Hz AC supply, complete all specified and directed. |
| 37 | S&F in repair 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed at site. |
| 38 | M&L for Sub main wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit medium grade/casing capping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and as directed at site. |
| 39 | Supply and fix in repair 35W energy saving and environmental friendly long life LED building security street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08, 10KV surge protection and having 130 lumen/watt including connection with twin twisted unsheathed PVC copper cable of suitable size along with suitable brackets with clamps, nuts and bolts complete all as specified and as directed.Make : Havells Cat No. ENDURASUNDOWNSL35WLED 765PASYBOPC/BRPO30PLED35CWSCRGRPSUSPD of Philips/ LRO2-391-XXX-57-XX35W of WIPRO or techno commercially equivalent make as approved by GE. |
| 40 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point including necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead including dismantling of old serviceable one complete all as specified and as directed. |
| 41 | Supply and fix in repair LED lights fitting 1x 20W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Havells Cat No. LUMILINEPLUSNEOBS20WLED865SPCSSIND /CCS-103-20-65-SL-DP-NWH of crompton or techno commercially equivalent make as approved by GE. |
| 42 | Supply and fix in repair LED lights fitting 1x 22W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Havells Cat No. LUMILINEPLUSNEOBS22WLED865SPCSSIND/ CCS-103-22-65-SL-DP-NWH of crompton or techno commercially equivalent make as approved by GE. |
| 43 | Supply and fix in repair LED lights fitting 1x 10W, 220V, AC decorative box type with powdered coated aluminium housing & integrated electronic driver with THD<10%, 4KV surge protection and 130 lumen/watt including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Havells Cat No. LUMILINE+BS10WLED865SPCSS/ CCS-103-10-65-SL-DP-NWH of crompton or techno commercially equivalent make as approved by GE. |
| 44 | S&F in repair CITY 3 Decorative wall light fixture made up of Polycarbonate, suitable for and including 9 W retrofit LED Lamp B22 base. complete all as specified and as directed at site.Make : Havells / Bajaj / Crompton Greaves. |
| 45 | S&F in repair 15W surface mounted LED slim round down lighter with high efficient LEDs & glare free opal diffuser, IP20 with integrated electronic driver including necessary connection all as specified and directed at site.Make : Havells Cat No. INTEGRANXTRDDLRSURD15WLED840S /D641865 OF Wipro or techno commercially equivalent make as approved by GE. |
| 46 | Supply & fix in repair LED down lighter 2'x2' , 34 W environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete all as specified and as directed.Make : Havells Cat No. PLANO2X2PLR34WLED865S //DA414065 of Wipro or techno commercially equivalent make as approved by GE. |
| 47 | S&F in repair 15W Coral LED Post Top gate light, IP 65 suitable for pole dia 50mm complete all as specified and as directed at site. |
| 48 | S&F in repair LED light fittings, 1x10 watts bulk head luminaires, IP66 complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cable of 23/0.0076 from ceiling rose all as specified. |
| 49 | S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amps MCB complete all as specified and directed at site. |
| 50 | S&F in repair bell ding dong AC single pole 230 volts complete all as specified and as directed at site. |
| 51 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspend- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed at site. |
| 52 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen- ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed at site. |
| 53 | M&L for Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 4 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade/casing capping with all fittings suitable for concealed/surface type and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and as directed at site. |
| 54 | S&F in repair 9 W LED bulb of base B22d with colour temp 6500K all as specified and directed. |
| 55 | Disconnecting and removing ceiling fan from any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine & replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of worn-out/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan including testing complete all as specified. NOTE :- (1) Necessary replacement of unserviceable parts/winding shall be measured and paid separately.(2)Labour element for replacing of unserviceable parts deemed to be included in rate quoted. |
| 56 | Supply only oil filled Capacitor, 2.5 mfd suitable for ceiling fan |
| 57 | Supply only Ball bearing suitable for ceiling fans including necessary greasing. Make: NBC/SKF/TATA |
| 58 | Supply only bushing suitable for ceiling fans /wall mounting fan/ exhaust fan. |
| 59 | Supply only Rubber bush with clamp, nuts and bolts for ceiling fan . |
| 60 | Supply only shaft made out of carbon steel including necessary lathe work for ceiling fan. |
| 61 | Taking out defective winding and rewinding of the ceiling fan of any sweep complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer's design and instructions including varnishing of ceiling fan of any make and any sweep complete all as specified and as directed |
| 62 | Supply and Fix 40W, decorative, wall mounted, ultra slim, polycarbonate, LED lighting fixture, (1205 x 66 x 76)mm, 6500K, with high lumen output, environmental friendly, energy efficient with electronic driver with all fixing arrangement etc., complete all as specified and as directed. |
| 63 | Supply and fix 1.5 Sqmm Copper wire single core with complete all as specified and as directed at site. |
| 64 | Supply and fix 2.5 Sqmm Copper wire single core with complete all as specified and as directed at site. |
| 65 | Supply and fix 4 Sqmm Copper wire single core with complete all as specified and as directed at site. |
| 66 | S&F in repair 3mm thick plastic laminated hylem sheet cover of size 100mm x 100mm for mounting switches, sockets, fan regulators, bell push etc. complete all as specified and directed at site. Note : Quoted rate includes cutting of hylem sheets for insertion/mounting of switches, sockets, fan regulators, bell push etc. |
| 67 | All as per Item No.65 above but of size 175mm x 100mm. |
| 68 | All as per Item No.65 above but of size 200mmx 150mm. |
| 69 | All as per Item No.65 above but of size 250mm x 200mm. |
| 70 | All as per Item No.65 above but of size 250mm x 300mm. |
| 71 | S&F in repair Modular white cover plate with frame, 1 module complete all as specified and as directed at site. Note : Quoted rate includes mounting of modular switches, sockets, fan regulators, bell push etc. |
| 72 | All as per Item No.70 above but 2 module. |
| 73 | All as per Item No.70 above but 3 module. |
| 74 | All as per Item No.70 above but 4 module. |
| 75 | All as per Item No.70 above but 6 module. |
| 76 | All as per Item No.70 above but 8 module. |
| 77 | S&F in repair 3mm thick plastic laminated hylem sheet cover of size 150mm x150mm |
| 78 | S&F in repair 3mm thick plastic laminated hylem sheet cover of size 200mm x200mmNote : (a) Contractor's supervisor / elect has to collect complaint slip/Job card from complaint cell, attend the complaint and complaint should be rectified on same day after receiving the complaint.(b) For repair/rewinding of ceiling fans shall be done at AGE E/M Subdivision only. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |