| 1 | Demolishing cement concrete manually by mechanical means including disposal of material within 50 metres lead |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size |
| 4 | Plain Reinnforced cement concretein sub structure complete as per drawing and technical specifications RCC Grade M 20 |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand |
| 6 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand |
| 7 | Steel work in built up tubular (round, square or rectangular hollow tubes ets.)trusses ets. |
| 8 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 9 | Providing and laying vitrified floor tiles in different sizes with eater absorption less than 0.08% |
| 10 | 18mm thik marine plywood |
| 11 | 10 mm Glass partittion fixed over the plywood carcass |
| 12 | Aluminium door And windwo |
| 13 | puf panel for wall 50 mm thick puf panel for outer side |
| 14 | 100 mm Thick Puf Roofing |
| 15 | 16 mm thick Bison Bord |
| 16 | Interlocking WPC louvers for Inside wall |
| 17 | 300 mm thick boxing with 6 mm thick HPL Board finish HPL Board cladding for 3d latter signage |
| 18 | coursed rubble masonry with hard stone first or second sort in superstructure above plinth level and upto floor five level Masonry work ( second sort) in cement mortar 1:6 |
| 19 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to is :13592 Type A including jointing with seal ring conforming to is |
| 20 | Providing and fixing on wall fae uplasticised PVC moulded fittings accessories for unplasticised Rigid PVC Rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10 mm gap for thermal expansion |
| 21 | Band 87 5 degree |
| 22 | Shoe (Plain) |
| 23 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50n *50*50 mm hard wood plugs screwed with MS screws of requirex length including |
| 24 | steel reinforcement for RCC work including straightening cuttiong bending placing in postion and binding all complete upto plinth level |
| 25 | sign Bord |
| 26 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 27 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.. (@ 20 mtr./Crt.) |
| 28 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 29 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 30 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 31 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 33 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 40Amp |
| 34 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required 63 Amp |
| 35 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 36 | Supplying and laying 6 SWG G.I Wire at 0.50 meter below ground level foe conductor earth electrode inlcding connection / termination with G.I thimble etc requried |
| 37 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 38 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mmheight, top lid of 1.5 mmthick M.S. sheet with its top surface hacked forproper bonding, top lidshall be screwed into the cast iron/ M.S. sheet boxby means of 3.3 mmdia round headed screws, one lock at the corners.Clamp shall be madeof 12 mm dia M.S. bar bent to shape as perstandard drawing. |
| 39 | Supply installation, testing and commissioning of 1200 mm sweep ,Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req |
| 40 | S/F single pole blanking plate in the existing MCB DB complete etc, as required ( 4 no / MCBDB ) |
| 41 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having singleprong at top, with85 mm dia 6 mm thick G.I. base plate includingholes etc.complete as required. |
| 42 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet orsurface of wall for lightning conductor complete asrequired.(For horizontal run) |
| 43 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 44 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts,nuts, chucknuts and spring washers etc. complete as required. |
| 45 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required |
| 46 | Electical accessories used in MSSCS Center ( LED Blub , Exaust Fand , Tube light , Fan , Ring Bell etc. |
| 47 | 3D sinage for MSSCS Center Please Enable Macros to View BoQ information |