| 1 | Supply, installation, testing, and commissioning of an IP-based PABX system with redundancy, comprising a 96-port gateway configured with 64 analog subscriber lines, inclusive of Caller Line Identification (CLI) licenses and voice guidance system.(Refer Section V, Clause No.10) |
| 2 | Supply, installation, load testing, and commissioning of 2 kVA online UPS system complete with batteries, providing 60 minutes backup at full load (rated capacity), including all accessories and required connections. |
| 3 | Supply and installation of following sizes of PLB HDPE pipes in Built-in -trench as per detailed specification. (Refer Sec VI, Clause No.4.1 & 4.3). |
| 4 | Supply and installation of 40/33mm HDPE Ducts in Built in trench for routing of Power /Telephone Cables as per the detailed specification. |
| 5 | Supply and installation of following sizes of HDPE Pipes Direct in Ground. |
| 6 | Supply and installation of PLB 40/33mm HDPE Ducts including excavation for routing of Power /Telephone Cables as per the detailed specification.(Refer Sec VI, Clause No.4.1 & 4.2). |
| 7 | Supply and installation of HDPE pipe across the Road |
| 8 | Supply and installation of 6mtr length DWC HDPE pipes, 200 mm OD / 175 mm ID with Coupler as required including cutting for crossing of existing road and excavation at a depth of 1200mm in all types of soil, backfilling, normalisation of road etc complete as directed by Engineer-in-Charge. 6mtr will be measured as 1No. (Refer Sec VI, Clause No.8.3). |
| 9 | Loading, Transportation, Unloading at site, installation, Testing and Commissioning of following size of LT/Telephone/OFC cable through the HDPE pipes as per the detailed specification enclosed. (Refer Sec VI, Clause No.4.5) |
| 10 | upto 3/4 C x 25 sq mm 1100 Volts Grade LT cable/ upto 20 Pair Telephone cable/OFC cable. |
| 11 | Wiring and termination for Telephone point with 1 Run of 0.6mm dia, twin twisted, two pair (avg: 15m length), tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking including supply of wire and two numbers of single module Jack type Telephone Socket with Shutter with Modular plate.(Refer Sec VI, Clause No.18) |
| 12 | Wiring and termination for Telephone point with 1 Run of 0.6mm, 250 V grade PVC insulated, twin twisted, single/Double pair, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking. (Refer Sec VI, Clause No.18). (Note: wire will be issued free of cost by the department). |
| 13 | Wiring with 1 Run of Twin twisted , Single pair (1/0.6mm ) |
| 14 | Wiring with 1 Run of Twin twisted , Double pair (1/0.6mm ) |
| 15 | Wiring and termination for Telephone point with 1 Run 0.6mm, twin twisted, 4 to 10 pair PVC wires, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking. (Note: wire will be issued free of cost by the department). |
| 16 | Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 17 | 20 X 12 mm size of PVC Mini trunking |
| 18 | 25 X 12 mm size of PVC Mini trunking |
| 19 | Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29) |
| 20 | 20 X 12 mm size of PVC Mini trunking |
| 21 | 25 X 12 mm size of PVC Mini trunking |
| 22 | Supply and installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, in Floor, Walls, Brick, Block Masonry, etc. including chasing & replastering as per the detailed specification.(Refer Sec VI, Clause No.27). |
| 23 | 32mm Dia, 2.5mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes. |
| 24 | 40mm Dia, 2.6mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes. |
| 25 | Termination of the following sizes of jelly filled armoured PIJF UG Cable using Single Compression, Heavy Duty Gland connecting the cable to the equipment Telephone DBs etc. The rate shall include the cost of supply of Cable Gland. The Contractor shall arrange for drilling of holes wherever necessary for the completion of the work. (Refer Sec VI, Clause No.10.2). |
| 26 | Upto 20 Pair |
| 27 | Above 20 & upto 50 Pair |
| 28 | Above 50 & Upto 100 Pair |
| 29 | Above 100 pair & Up to 200 Pair |
| 30 | Retrieval of the already laid one number Telephone cable of following sizes direct in ground including removal of end termination, excavation of trenches, retrieving of bricks and back filling as per the detailed specification. (Refer Sec VI, Clause No.5) |
| 31 | Upto 20 Pair/OFC cable. |
| 32 | Above 20 Pair & upto 50 Pair |
| 33 | Above 50 Pair & upto 200 Pair |
| 34 | Retrieval of the already laid one number Telephone cables of following sizes in built-in trenches, on walls, poles and from embedded pipes including removal of end termination, GI spacer, clamps etc as per the detailed specification. (Refer Sec VI, Clause No.5) |
| 35 | Upto 20 Pair/OFC cable. |
| 36 | Above 20 Pair & upto 50 Pair |
| 37 | Above 50 Pair & upto 200 Pair |
| 38 | Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10). |
| 39 | 150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box. |
| 40 | 300(W)X300(H)X120(D)mm,1.8mm thick sheet MS Box. |
| 41 | Supply and installation of Powder coated MS boxes with SS KRONE base module (i.e. For mounting of telephone Krone disconnection modules) for the following D.B sizes. (Ref. Sec VI, Clause No.15.10 & Sec V). |
| 42 | 300(W)X300(H)X120(D)mm MS Box. (50 pair) |
| 43 | 500(W)x300(H)x150(D) MS Box. (100 pair) |
| 44 | 500(W)x500(H)x150(D) MS Box - (100xL+100xR = 200 pair) (Note: L - Left side Krone base, R- Right side Krone base fixing) |
| 45 | 750(W)x500(H)x150(D) MS Box - (100x2L+100x2R = 400 pair) (Note: L - Left side Krone base, R- Right side Krone base fixing) |
| 46 | 750(W)x750(H)x150(D) MS Box - (100x2L+100x2M+100x2R = 600 pair) (Note: L - Left side Krone base, R- Right side Krone base fixing) |
| 47 | Supply and installation of KRONE modules, refixing, re-termination and cross jumpering work for existing telephone DB after removing the damaged KRONE Modules (10 pair each) in various locations/buildings at IGCAR site as per the scope of work.(Refer Sec V). |
| 48 | Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6). |
| 49 | Surface Mounting Plastic Boxes 1/2 Module |
| 50 | Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7). |
| 51 | Two module |
| 52 | Supply and Installation of RJ-11 socket 1 Gang with shutter for information outlet and termination of 1 Run of data Cable. |
| 53 | Wiring and termination for Telephone point with 1 Run of 0.6 mm dia, 250 V grade PVC insulated, twin twisted,Two pair, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking including of supply of Telephone wire. (Refer Sec VI, Clause No.18) |
| 54 | Wiring with 1 Run of Twin twisted, Two pair (1/0.6mm). |
| 55 | Supply and installation of FMS box with all required accessories and terminating the same in a 19\\" APW rack or wall mountable as per site requirement. (Refer Sec V) |
| 56 | 6/12 Core SM FMS box |
| 57 | Supply and installation of following heat shrinkable straight jointing kit of reputed make (for underground burial) including all necessary splicing materials, mounting base tray and joint enclosures for the following OFC cables. (Refer Sec V) |
| 58 | 6/12 Core Single Mode (SM) |
| 59 | Supply, installation, testing, and commissioning of e-Z32-2 analog interface modules with all mandatory licenses including High Availability (HA) license, NMS license, CLI license, networking licenses, and other minor/supporting licenses, along with 15 m MDF TY1 64-point DIN cable and all associated accessories required for complete integration. (Refer Sec V). |
| 60 | OFC cable performance test on all cores and rectification of faulty cores as per the details mentioned in the scope of work. (Refer Sec V). Please Enable Macros to View BoQ information |